Clinical Trial Results for Defibrillator (AICD)

7 Clinical Trials for Defibrillator (AICD)

Focus your search

RECRUITING
Programmed Ventricular Stimulation to Risk Stratify for Early Cardioverter-Defibrillator (ICD) Implantation to Prevent Tachyarrhythmias Following Acute Myocardial Infarction (PROTECT-ICD)
Description

The PROTECT-ICD trial is a physician-led, multi-centre randomised controlled trial targeting prevention of sudden cardiac death in patients who have poor cardiac function following a myocardial infarct (MI). The trial aims to assess the role of electrophysiology study (EPS) in guiding implantable cardioverter-defibrillator (ICD) implantation, in patients early following MI (first 40 days). The secondary aim is to assess the utility of cardiac MRI (CMR) in analysing cardiac function and viability as well as predicting inducible and spontaneous ventricular tachyarrhythmia when performed early post MI. Following a MI patients are at high risk of sudden cardiac death (SCD). The risk is highest in the first 40 days; however, current guidelines exclude patients from receiving an ICD during this time. This limitation is based largely on a single study, The Defibrillator in Acute Myocardial Infarction Trial (DINAMIT), which failed to demonstrate a benefit of early ICD implantation. However, this study was underpowered and used non-invasive tests to identify patients at high risk. EPS identifies patients with the substrate for re-entrant tachyarrhythmia, and has been found in multiple studies to predict patients at risk of SCD. Contrast-enhanced CMR is a non-invasive test without radiation exposure which can be used to assess left ventricular function. In addition, it provides information on myocardial viability, scar size and tissue heterogeneity. It has an emerging role as a predictor of mortality and spontaneous ventricular arrhythmia in patients with a previous MI. A total of 1,058 patients who are at high risk of SCD based on poor cardiac function (left ventricular ejection fraction (LVEF) ≤40%) following a ST-elevation or non-STE myocardial infarct will be enrolled in the trial. Patients will be randomised 1:1 to either the intervention or control arm. In the intervention arm all patients undergo early EPS. Patients with a positive study (inducible ventricular tachycardia cycle length ≥200ms) receive an ICD, while patients with a negative study (inducible ventricular fibrillation or no inducible VT) are discharged without an ICD, regardless of the LVEF. In the control arm patients are treated according to standard local practice. This involves early discharge and repeat assessment of cardiac function after 40 days or after 90 days following revascularisation (PCI or CABG). ICD implantation after 40 days according to current guidelines (LVEF≤30%, or ≤35% with New York Heart Association (NYHA) class II/III symptoms) could be considered, if part of local standard practice, however the ICD is not funded by the trial. A proportion of trial patients from both the intervention and control arms at \>48 hours following MI will undergo CMR to enable correlation with (1) inducible VT at EPS and (2) SCD and non-fatal arrhythmia on follow up. It will be used to simultaneously assess left ventricular function, ventricular strain, myocardial infarction size, and peri-infarction injury. The size of the infarct core, infarct gray zone (as a measure of tissue heterogeneity) and total infarct size will be quantified for each patient. All patients will be followed for 2 years with a combined primary endpoint of non-fatal arrhythmia and SCD. Non-fatal arrhythmia includes resuscitated cardiac arrest, sustained ventricular tachycardia (VT) and ventricular fibrillation (VF) in participants without an ICD. Secondary endpoints will include all-cause mortality, non-sudden cardiovascular death, non-fatal repeat MI, heart failure and inappropriate ICD denial. Secondary endpoints for CMR correlation will include (1) the presence or absence of inducible VT at EP study, and (2) combined endpoint of appropriate ICD activation or SCD at follow up. It is anticipated that the intervention arm will reduce the primary endpoint as a result of prevention of a) early sudden cardiac deaths/cardiac arrest, and b) sudden cardiac death/cardiac arrest in patients with a LVEF of 31-40%. It is expected that the 2-year primary endpoint rate will be reduced from 6.7% in the control arm to 2.8% in the intervention arm with a relative risk reduction (RRR) of 68%. A two-group chi-squared test with a 0.05 two-sided significance level will have 80% power to detect the difference between a Group 1 proportion of 0.028 experiencing the primary endpoint and a Group 2 proportion of 0.067 experiencing the primary endpoint when the sample size in each group is 470. Assuming 1% crossover and 10% loss to follow up the required sample size is 1,058 (n=529 patients per arm). To test the hypothesis that tissue heterogeneity at CMR predicts both inducible and spontaneous ventricular tachyarrhythmias will require a sample size of 400 patients to undergo CMR. It is anticipated that the use of EPS will select a group of patients who will benefit from an ICD soon after a MI. This has the potential to change clinical guidelines and save a large number of lives.

RECRUITING
Implantable Cardioverter Defibrillator (ICD Registry)
Description

The ICD Registry™ is a nationwide quality program that helps participating hospitals measure and improve care for patients receiving implantable cardioverter defibrillators (ICDs) and cardiac resynchronization therapy devices with defibrillator (CRT-Ds). The ICD Registry captures the characteristics, treatments, and outcomes of patients receiving (ICDs). Patient-level data is submitted by participating hospitals on a quarterly basis to the American College of Cardiology Foundation's (ACCF) National Cardiovascular Data Registry (NCDR) which then produces an Outcomes Report of the hospital's data, with comparison to both a volume peer group (number of ICD patients submitted annually) and the entire ICD registry data set.

RECRUITING
Safety and Performance Assessment of the Sphere-9™ Catheter and Affera™ Ablation System for the Treatment of Ventricular Tachycardia
Description

Sphere-9 VT is a prospective, multi-center, non-randomized, unblinded feasibility study. Adult subjects with recurrent, sustained, monomorphic ventricular tachycardia due to prior myocardial infarction will be enrolled and treated with the Sphere-9 Catheter and Affera Ablation System.

RECRUITING
Comparative Effectiveness of Prophylactic ICD Versus Non-ICD Therapy
Description

The investigators aim to compare the risk of mortality of Non-implantable carioverter defibrillator (ICD) vs. ICD management in patients with heart failure with reduced ejection fraction (HFrEF).

RECRUITING
Self-Management Interventions After an ICD Shock
Description

This study, "Biobehavioral Intervention to Reduce PTSD Symptoms After an ICD Shock," addresses a critical need in cardiology care by describing the feasibility and acceptability of a timely, highly promising, electronically-delivered intervention for patients who have recently received an ICD delivered shock. The study intervention and outcomes are designed to reduce anxiety, enhance return to activities of daily living (ADLs), and prevent the development of severe distress and post-traumatic stress disorder (PTSD), and ultimately promote quality of life. The study is a two-arm, embedded mixed methods, randomized trial (N=60, 30/group). The purpose is to determine feasibility and potential effects of a self-management intervention (SPSM) plus usual care (UC) compared to UC alone, delivered during the critical 1 month period after an ICD shock when distress is high. The intervention will be delivered over 1 month following an ICD shock; a 6-month follow-up will be used to assess the sustainability of intervention effects and determine if the incidence of PTSD is reduced. SPSM includes: 1) training in heart rate (HR) self-monitoring; and 2) individualized learning through 4 self-paced, web-based modules. The study interventions are delivered at a crucial time, closely after an ICD shock when stress is high, but PTSD has not yet developed. The specific aims are to: 1) examine the effects of the SPSM intervention plus UC vs. UC alone on the primary outcome of ICD shock anxiety at 1 and 6 months post-shock event, 2) describe the impact of SPSM plus UC compared to UC alone on the secondary outcomes of total daily physical activity, depression, PTSD symptoms, QOL, salivary cortisol levels, and self-efficacy and outcome expectations at 1 and 6 months post-shock event, and 3) assess feasibility, acceptability, and safety of the SPSM intervention, SDOH will be used to describe differential responses to the SPSM intervention. This study fills a significant gap in the care of patients with an ICD, through the systematic testing of a brief, novel and cost-effective intervention that provides the knowledge and skills to improve quality of life. Study findings will be used to design future larger RCTs to test intervention effectiveness for more diverse samples and settings.

RECRUITING
Assessment of Combined CCM and ICD Device in HFrEF
Description

The goal of this clinical trial is to demonstrate that the OPTIMIZER® Integra CCM-D System (the "CCM-D System") can safely and effective convert induced ventricular fibrillation (VF) and spontaneous ventricular tachycardia and/or ventricular fibrillation (VT/VF) episodes in subjects with Stage C or D heart failure who remain symptomatic despite being on guideline-directed medical therapy (GDMT), are not indicated for cardiac resynchronization therapy (CRT), and have heart failure with reduced left ventricular ejection fraction (LVEF ≤40%). Eligible subjects will be implanted with the CCM-D System. A subset of subjects will be induced into ventricular fibrillation "on the table" in the implant procedure room. During the follow-up period, inappropriate shock rate and device-related complications will be evaluated. The follow-up period is expected to last at least two years.

RECRUITING
Prospective Observational Study of the ICD in Sudden Cardiac Death Prevention
Description

The overall hypothesis of this study is that subtle interactions between structural (substrate) and functional (trigger) abnormalities of the heart, some of which are genetically-determined, can be used to identify patients at high risk of sudden cardiac death (SCD). Such information may be used to better define patients most likely to benefit from replacement of an internal defibrillator (ICD). The prospective, observational study to enroll, categorize and follow patients who receive an ICD pulse generator replacement for primary prevention of SCD (PROSe-ICD) was established to : 1. to gain a better understanding of the biological mechanisms that predispose to SCD 2. to develop readily determined clinical, electrocardiographic, genetic and blood protein markers identify patients with an increased risk of dying suddenly