Establishing Baseline Sysmex UF-5000 Flow Cytometer Results in Healthy Men

Description

Acute urethritis (inflammation of the male urethra) affects millions of men in the United States each year. Effective management of STIs is complicated by asymptomatic infections, as men often delay seeking care until symptoms become severe. Yet, even men without symptoms can show measurable evidence of urethritis. Therefore, a cheap, simple, and non-invasive point-of-care (POC) test, providing results within 30 minutes, could significantly enhance STI management by facilitating early diagnosis and treatment. A new diagnostic method, urine flow cytometry, has shown potential in hospital settings for accurately detecting inflammation by counting white blood cells (infection-fighting cells) in urine samples. The Sysmex UF-5000 flow cytometer, a state-of-the-art device, may offer a non-invasive, cost-effective, and accurate method to diagnose urethritis compared to traditional Gram stains and urinalysis, potentially extending its use beyond specialized clinics. This study aims to determine the efficacy and precision of the Sysmex UF-5000 analyzer in diagnosing urethritis using first-catch urine samples. Additionally, the study seeks to evaluate whether urine collected using the 10 mL Colli-Pee device provides greater accuracy and precision compared to the standard urine cup (30-60 mL) when used with urine flow cytometry and LE urinalysis.

Study Overview

Study Details

Study overview

Acute urethritis (inflammation of the male urethra) affects millions of men in the United States each year. Effective management of STIs is complicated by asymptomatic infections, as men often delay seeking care until symptoms become severe. Yet, even men without symptoms can show measurable evidence of urethritis. Therefore, a cheap, simple, and non-invasive point-of-care (POC) test, providing results within 30 minutes, could significantly enhance STI management by facilitating early diagnosis and treatment. A new diagnostic method, urine flow cytometry, has shown potential in hospital settings for accurately detecting inflammation by counting white blood cells (infection-fighting cells) in urine samples. The Sysmex UF-5000 flow cytometer, a state-of-the-art device, may offer a non-invasive, cost-effective, and accurate method to diagnose urethritis compared to traditional Gram stains and urinalysis, potentially extending its use beyond specialized clinics. This study aims to determine the efficacy and precision of the Sysmex UF-5000 analyzer in diagnosing urethritis using first-catch urine samples. Additionally, the study seeks to evaluate whether urine collected using the 10 mL Colli-Pee device provides greater accuracy and precision compared to the standard urine cup (30-60 mL) when used with urine flow cytometry and LE urinalysis.

Establishing Baseline Sysmex UF-5000 Flow Cytometer Results in Healthy Men

Establishing Baseline Sysmex UF-5000 Flow Cytometer Results in Healthy Men

Condition
Urethritis
Intervention / Treatment

-

Contacts and Locations

Indianapolis

Indiana University, Indianapolis, Indiana, United States, 46202

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

For general information about clinical research, read Learn About Studies.

Eligibility Criteria

  • * Men aged 18 to 50.
  • * No urethral symptoms (discharge, dysuria)
  • * History of genital surgery or known urethral abnormalities
  • * Testing positive for gonorrhea and chlamydia
  • * Diagnosis of a sexually transmitted infection within the last year.
  • * Not available to collect a urine specimen in the morning 3x/week for 2 weeks

Ages Eligible for Study

18 Years to 50 Years

Sexes Eligible for Study

MALE

Accepts Healthy Volunteers

Yes