36 Clinical Trials for Various Conditions
The purpose of this research is to design a high-performance, customized, and rapidly- manufacturable passive prosthetic foot for use in the United States. We are currently testing an early stage prototype and would like user input before pursuing additional clinical testing. Participants will be asked about their current prosthesis type and use, amputation side and cause, and activity level. We will take measurements of height, weight, and length of the participant's residual limb. The participant will be asked to walk in several prosthetic foot conditions in multiple walking activities, and the visit should last approximately four hours. For each prosthetic foot, a trained prosthetist will fit the foot (either a prototype foot or a commercially available K3/K4 foot) to the prosthesis. The patient will then walk around the room until they feel comfortable. They may initially walk using a gait belt or between parallel bars based on comfort level and an evaluation by the prosthetist. Once they feel comfortable walking on level ground at a normal speed and the prosthetist feels that they will be safe performing more challenging walking activities, the participant will perform different walking activities (such as walking on flat ground at different speeds, walking up/down ramps, and walking up/down stairs). They will then be asked to tell the investigator what they like and dislike about the prosthetic foot.
The Ossur Prosthetic Power Knee claims to assist in helping people with transfemoral amputation to walk up stairs and stand up from sitting. We expect to find that this product has the ability to help unload the sound knee during these tasks. We plan to collect force and motion data while people stand up from a chair. We will compare the data from people using several types of prosthetic knees, including the power knee as well as from people who are not amputees to see what the force and motion contributions are from the different knees evaluated.
The purpose of this research is to determine the feasibility of an uneven terrain walking program for lower limb prosthesis users. The training is designed to induce step-to-step variability during walking within a safe environment, with the aim of improving walking skill and confidence.
The objective of this study is to develop a virtual rehabilitation system that can be used to effectively treat Phantom Limb Pain (PLP) within the research setting and for at-home use by individuals with upper and lower extremity amputation. We hypothesize that the system will improve PLP for individuals with upper or lower extremity amputation, as measured through with various outcome measures and questionnaires.
The purpose of this study is to evaluate the feasibility and efficacy of a smart airbag system that detects and mitigates fall-related impact in individuals with high fall risk.
Lower limb amputation is common in the United States, with approximately 150,000 amputations annually. Most individuals walking with a prosthesis demonstrate asymmetrical loading-i.e., they favor the amputated side by placing more weight and increased ground reaction forces through the intact limb-which likely contributes to increased metabolic cost of walking. Lack of adequate muscular strength in the lower limb to attenuate these forces places increased stress on the joints, which may be displaced proximally, and may play a role in reported knee and hip pain in the intact limb. Lower limb muscle weakness following amputation has been well documented. Increasing quadriceps strength is important after an amputation because it is positively correlated with gait speed. Gait speed may also be associated with successful community mobility, which leads to improved quality of life following amputation. Individuals with amputation who resume an active lifestyle are able to maintain strength. However, these individuals represent a minority of persons with lower limb amputation; most individuals report more barriers than motivators to adopt an active lifestyle. Ischemic conditioning (IC) may strengthen leg muscles and reduce the metabolic cost of activity after amputation. In IC, the limb is exposed to brief, repeated bouts of ischemia (reduced blood flow) immediately followed by reperfusion. IC has been shown to improve muscle performance in healthy and diseased populations. IC has also been used more recently in patients with peripheral artery disease (PAD) as an intervention to improve function, such as walking ability. Acute exposure to IC increases muscle strength and activation, both in healthy, active individuals and in those with severe neuromuscular dysfunction, such as stroke survivors. IC also attenuates muscular fatigue. Increased fatigue resistance at submaximal contraction levels following IC may be due to increased neural activation of skeletal muscle. Changes in neural activation of muscle may be particularly beneficial during cortical reorganization after amputation. Reduced quadriceps fatigue during submaximal activities may also drive changes in gait kinematics, such as increased knee flexion during loading and mid-stance. Exposure to IC may also increase the oxidative properties of skeletal muscle, offering a direct pathway to reduce metabolic cost. Therefore, IC may lead to cellular changes that lower the metabolic cost of activity. The primary aim of this study is to quantify the benefits of acute and chronic IC on quadriceps strength and walking economy in individuals with PAD and history of lower limb amputation.
Two-phased randomized controlled trial comparing the impact of microprocessor controlled knee prostheses (MPK) with the impact of non-microprocessor controlled knee prostheses (NPMK) in patients with a transfemoral/knee disarticulation level amputation categorized as K2 ambulators.
A prospective, interventional, multicenter pilot study to characterize differences in performance and patient reported outcomes between the Taleo, Proflex XC, and the new Revo prosthetic foot.
In this pilot clinical study the investigators propose to conduct a prospective, randomized, double-blinded, placebo-controlled clinical trial for 30 days for participants with critical limb ischemia (CLI) who undergo a major (above-knee or below-knee) lower extremity amputation. By exploring the primary endpoints we aim to determine whether NAC can affect amputation stump perfusion and healing. Based on preclinical data, the investigators hypothesize that NAC will augment both amputation stump perfusion as well as healing. The investigators will utilize the data from this trial to determine the true effect size that is necessary for a larger clinical trial to determine the clinical efficacy of NAC is healing surgical sites such as major lower extremity amputation stumps.
The goal of this clinical trial is to identify prosthesis stiffness that optimizes balance control in individuals with below knee amputations. The main question this clinical trial will answer is: • Is there an optimal stiffness that improves balance control for specific ambulatory activities and users? Participants will wear a novel prosthesis assembled with three prosthetic feet with a range of stiffness levels: each individual's clinically-prescribed foot stiffness and ± two stiffness categories. While wearing the study prostheses, participants will perform nine ambulatory activities of daily living (walking at different speeds, turning, ramp ascent/descent, while carrying a load, and while walking on uneven terrain).
The objective of this proposal is to investigate the effects of training to use direct electromyographic (dEMG) control of a powered prosthetic ankle on transtibial amputees'. The aimed questions to answer: 1. whether dEMG control will improve balance and postural stability of amputees, 2. whether dEMG control will lead to more natural neuromuscular control and coordination, 3) whether dEMG control will reduce cognitive processes. Participants will go through PT guided training on using dEMG controlled prosthetic ankles and are evaluated for their capability on functional tasks. The results will be compared with a comparison group, which goes through the same training but with their everyday passive prostheses on balance capability, neuromuscular coordination, and cognitive load during locomotion.
Lower limb amputees (LLA) rely on their prosthetic legs to remain active and lead an independent life. For most LLAs, a well-fitted prosthetic socket is the only option to interface with their prosthetic leg, however, it is a real challenge to make a prosthetic socket to interface with residual limbs accurately. One of the reasons is that there lack of accurate approaches to evaluate the pressure distribution on the residual limb accurately and effectively. To overcome this issue, the research team will develop an innovative sensing system, which permits the prosthetists to track the pressure distribution on the residual limb visually. The capability of the new sensing system will be demonstrated on lower limb amputees.
People with leg amputations often experience daily changes in the size (volume) of their residual limb. These daily changes can cause a prosthesis to fit poorly. They can also cause limb problems like pain or skin breakdown. Prosthetic socket systems that accommodate limb volume changes can help address these issues, but they require users to make adjustments throughout the day. The aim of this research is to create a system that will automatically adjust the fit of the socket and create a well-fitting prosthesis for people with leg amputations who experience volume fluctuations when using their prosthesis.
The goal of the research is to create and evaluate a new technology for management of daily residual limb fluid volume fluctuation.
The purpose of this study is to address footwear challenges unique to women prosthesis users. Comparing the effectiveness of different footwear and prosthesis combinations will help guide clinical decision making regarding the prescription of prosthetic devices, while keeping what the patient wants in mind. It is expected that these results will be used to generate new knowledge for the development of versatile prosthetic devices that accommodate a user's unique lifestyle while helping the patient to make good progress in rehabilitation. Investigators will characterize perceived limitations in footwear among women prosthesis users. Investigators think that women prosthesis users will be restricted in footwear choices and clothing choices due to the use of a prosthetic device. Specifically, investigators expect perceived limitations in footwear will be greater for shoes with higher heels than shoes without heels.
The aim of this research is to create a prosthetic system that will automatically adjust the fit of the socket and create a well-fitting prosthesis for people with leg amputations who experience volume fluctuations when using their prosthesis.
Patients with limb amputations experience the sensation of the missing extremity, which is sometimes coupled with a persistent and debilitating pain in the missing limb, a condition known as phantom limb pain (PLP). This study will test the use of virtual reality (VR) training as a possible treatment of PLP.
This study will assess if the functional performance and musculoskeletal outcome of transfemoral amputees are improved after receiving a Microprocessor Knee (MPK) compared to a Non-Microprocessor Knees (NMPK).
The purpose of this study is to investigate how residual limb fluid volume, gait, prosthesis use, perceived comfort, and satisfaction with the prosthesis are affected by size of the prosthetic socket. Subjects are tested after wearing a nominal socket for 1 month and again after wearing a slightly oversized socket for 1 month.
The goal of this study is to find out if using microprocessor-controlled prosthetic knees (MPKs), prosthetic knees with a built-in computer, improves health outcomes related to falls in adults who use above-knee prostheses. The main questions are: * Do individuals with MPKs have fewer fall-related health issues compared to those with non-microprocessor-controlled prosthetic knees (nMPKs)? * Do individuals with MPKs have increased mobility, faster walking speed, and improved quality of life compared to those with nMPKs? Participants who have recently received an nMPK as part of their regular care can join the study. Those randomized to the control group will keep using their nMPK, while those randomized to the intervention group will receive a stance-and-swing MPK or a stance-only MPK.
The goal of this proposed project is to gather community-based data from the K2-level Transfemoral Amputee (TFA) population to aid in evidence-based prescription of powered prosthetic knees (i.e., choosing the right device to maximize the benefit for each patient). The investigators intend to use this trial data along with a concurrent study being conducted within the K3-K4 level population to guide the implementation of effective prescriptions towards those that can benefit most from a given device and limit prescription to those who would not see benefit in order to ensure the most judicious use of Department of Defense (DoD) and Veteran's Affairs healthcare dollars. The findings will also be shared with the research community to help drive the design of future devices by identifying what features and functions are most beneficial to which patient populations when the devices are used outside of the laboratory. In summary, more community-based data on how powered prosthetic knees compare with the current standard in TFA populations is needed to allow for improved clinical decision making and clinical outcomes.
The purpose of this study is to develop a database that contains movement and rehabilitation-related data collected through the use of wearable sensors and video. This database will serve as a resource for clinicians and researchers interested in the investigation of movement or rehabilitation-related research ideas.
The goal of this proposed project is to gather community-based data from the K4-level Transfemoral Amputee (TFA) population to aid in evidence-based prescription of powered prosthetic knees (i.e., choosing the right device to maximize the benefit for each patient). The investigators envision that this Level 1 submission will transition into a larger follow-on Level 2 trial that will explore a larger spectrum of patient populations (K2-K4), as well as testing additional Power Knees currently in development that are expected to become commercialized in the near future. The investigators intend to use this Level 2 trial data to guide the implementation of effective prescriptions towards those that can benefit most from a given device and limit prescription to those who would not see benefit in order to ensure the most judicious use of Department of Defense (DoD) and Veteran's Affairs healthcare dollars. The findings will also be shared with the research community to help drive the design of future devices by identifying what features and functions are most beneficial to which patient populations when the devices are used outside of the laboratory. In summary, more community-based data on how powered prosthetic knees compare with MPKs is needed to allow for improved clinical decision making and clinical outcomes.
The comfort and fit of the residual limb within a prosthetic socket are of primary concern for many amputees. The residual limb is typically covered by non-breathable and non- thermally conductive materials that can create a warm and ultimately moist environment. To address this, Liberating Technologies, Inc. (LTI) and Vivonics, Inc. have developed a thermo-electric cooling (TEC)-based module called the Intrasocket Cooling Element (ICE), that can be embedded into the prosthesis in order to cool the residual limb. A technology that can provide thermal control while retaining adequate suspension, weight and other prosthetic characteristics would benefit many prosthesis wearers.
The ultimate objective of the proposed line of research is to determine if cryoanalgesia is an effective adjunctive treatment for pain in the period immediately following various painful surgical procedures; and, if this analgesic modality decreases the risk of persistent postoperative pain, or "chronic" pain. The objective of the proposed pilot study is to optimize the protocol and collect data to power subsequent, definitive clinical trials. Specific Aim 1: To determine if, compared with current and customary analgesia, the addition of cryoanalgesia decreases the incidence and severity of post-surgical pain. Hypothesis 1a (primary): The severity of surgically-related pain will be significantly decreased on postoperative day 2 with the addition of cryoanalgesia as compared with patients receiving solely standard-of-care treatment. Hypothesis 1b: The incidence of chronic pain will be significantly decreased one year following surgery with the addition of cryoanalgesia as compared with patients receiving solely standard-of-care treatment. Hypothesis 1c: The severity of chronic pain will be significantly decreased one year following surgery with the addition of cryoanalgesia as compared with patients receiving solely standard-of-care treatment. Specific Aim 2: To determine if, compared with current and customary analgesia, the addition of cryoanalgesia improves postoperative functioning. Hypothesis 2a: Following primary unilateral knee and shoulder arthroplasty as well as rotator cuff repair, joint range of motion will be significantly increased within the year following surgery with the addition of cryoanalgesia as compared with patients receiving solely standard-of-care treatment. Hypothesis 2b: Following video-assisted thoracoscopic surgery, inspiratory spirometry will be improved within the month following surgery with the addition of cryoanalgesia as compared with patients receiving solely standard-of-care treatment.
In older adults, poor circulation in the lower extremities leads to serious health complications including limb loss. In addition, individuals with dysvascular disease also suffer from other co-morbidities like diabetes, coronary and cerebrovascular disease. An individual with a transfemoral (TF) amputation is usually fitted with a prosthetic limb to assist with function, including a prosthetic knee and a prosthetic foot. Currently, dysvascular amputees are given a prosthetic knee based on the basic expectation that they will be functionally stable. This consideration does not address higher levels of function like walking at multiple speeds and over uneven ground. Also, dysvascular amputees are not able to counteract their co-morbidities with a more active lifestyle. Walking is less energy efficient; their traditional prostheses may cause early onset of fatigue and induce a fear of falling. Newer microprocessor knees enable patients with transfemoral amputations to walk on different surfaces and at multiple cadences through better control in swing and stance phases of gait. The impact of the functional differences in the prostheses is not clear and requires additional investigation to clarify the choice of the most appropriate functional prosthesis. The purpose of this study is to compare the functional outcomes with the traditional mechanical knee versus the microprocessor knee (C-leg) in transfemoral amputees.
When a limb is severed, pain perceived in the part of the body that no longer exists often develops and is called "phantom limb" pain. Unfortunately, phantom pain goes away in only 16% of afflicted individuals, and there is currently no reliable definitive treatment. The exact reason that phantom limb pain occurs is unclear, but when a nerve is cut-as happens with an amputation-changes occur in the brain and spinal cord that actually increase with worsening phantom pain. These abnormal changes may often be corrected by putting local anesthetic-called a "nerve block"-on the injured nerve, effectively keeping any "bad signals" from reaching the brain with a simultaneous resolution of the phantom limb pain. However, when the nerve block resolves after a few hours, the phantom pain returns. But, this demonstrates that the brain abnormalities-and phantom pain-that occur with an amputation are not necessarily fixed, and may be dependent upon the "bad" signals being sent from the injured nerve(s), suggesting that a very long peripheral nerve block-lasting many months rather than hours-may permanently reverse the abnormal changes in the brain, and provide definitive relief from phantom pain. A prolonged nerve block lasting a few months may be provided by freezing the nerve using a process called "cryoneurolysis". The ultimate objective of the proposed research study is to determine if cryoanalgesia is an effective treatment for intractable post-amputation phantom limb pain. The proposed pilot study will include subjects with an existing above-knee amputation who experience intractable daily phantom limb pain. A single ultrasound-guided treatment of cryoneurolysis (or sham block-determined randomly like a flip of a coin) will be applied to the major nerves of the thigh. Although not required, each subject may return 4-6 months later for the alternative treatment (if the first treatment is sham, then the second treatment would be cryoneurolysis) so that all participants have the option of receiving the active treatment. Subjects will be followed for a total of 12 months with data collected by telephone.
Amputees wearing a conventional prosthesis require 20-30% more metabolic energy to walk at the same speeds as non-amputees and this discrepancy is more apparent at faster walking speeds. Amputees choose to walk at speeds 30-40% slower than non-amputees. Preferred walking speed is likely influenced by elevated metabolic energy, but the underlying reason for slower preferred walking speeds is not fully understood. Unilateral amputees exhibit highly asymmetrical gait patterns that likely require more metabolic energy and impair functional mobility, increasing the risk of degenerative joint disease, osteo-arthritis and lower back pain. Improvements in prosthetic devices could enhance mobility in amputees, thus positively effecting rehabilitation and ambulation in veterans. A prosthesis that allows amputees to reduce metabolic energy would be especially useful for rehabilitation in older, ill individuals with reduced exercise capacities and could literally restore walking ability in people that are currently non-ambulatory. Hypotheses. Amputees wearing the Massachusetts Institute of Technology (MIT) Powered Ankle-Foot (PAF) prosthesis will have a lower metabolic cost, faster preferred walking speed, and improved gait symmetry during walking than amputees wearing a conventional prosthesis and will have nearly the same metabolic cost, preferred walking speed, and gait symmetry during walking as age, gender, height, and weight matched non-amputees.
Despite recent advances in physical rehabilitation, Veterans with lower-limb amputation have poor long-term outcomes, including severely limited functional capacity and high levels of disability. Such poor outcomes are compounded by a lack of exercise participation over time, even with use of lower-limb prostheses. There is a clear need to advance current rehabilitation strategies to better promote sustained exercise following lower-limb amputation. To address this need, the study will determine the potential of a walking exercise self-management program to achieve sustained exercise participation. The 18-month intervention is focused on helping Veterans reduce habitual sedentary behavior through a remote exercise behavior-change intervention that includes multiple clinical disciplines, individualized exercise self-management training, and peer support. This innovative approach shifts the conventional rehabilitation paradigm to specifically target life-long exercise sustainability and remove an underlying cause of disability for Veterans with lower-limb amputation.
When prescribing a prosthetic foot, clinicians face a dizzying array of choices as more than 200 different prosthetic feet are available. While these conventional prosthetic feet primarily function in the sagittal plane, the intact foot and ankle comprise a complex set of joints that allow rotation in multiple planes of motion. Some of these motions are coupled, meaning rotation in one plane induces motion in another. One such coupling is between the sagittal and transverse planes. For every step, plantar- and dorsi-flexion motion in the sagittal plane is coupled with external and internal rotation of the shank relative to the foot in the transverse plane. There is no prosthetic foot available for prescription that mimics this natural coupling. To investigate the need for this coupling, the investigators have built a torsionally adaptive prosthesis where the coupling ratio between the transverse- and sagittal-planes can be independently controlled with a motor. This research has one specific aim: to identify the optimal coupling ratio between transverse- and sagittal-plane motions using a novel, torsionally adaptive prosthesis for individuals with lower limb amputation. The investigators will conduct a human subject experiment wearing the motor-driven and computer controlled torsionally adaptive prosthesis. Individuals with lower limb amputation will be asked to walk in a straight line and in both directions around a circle while the coupling ratio between transverse- and sagittal-plane motions is varied between trials. Participants will be blinded to the coupling ratio. The investigators hypothesize that: (1) a coupling ratio exists that minimizes undesirable transverse-plane socket torque and (2) there will be a coupling ratio that individuals with lower limb amputation prefer.