62 Clinical Trials for Various Conditions
Objective The objective of this study is to discover whether an infusion of nicardipine is able to reduce the time taken to achieve electrocerebral silence (ECS) during cardiopulmonary bypass (CPB) for aortic surgery. Hypothesis By inhibiting cold-induced cerebral vasoconstriction, nicardipine will maintain cerebral blood flow and allow more rapid cooling of the brain during CPB. This will manifest as a reduction in the time taken to achieve ECS and also as a reduction in overall CPB time.
The purpose of this external evaluation is to assess the system functionality and analytical performance of the Saturn Investigational Instrument (next generation VerifyNow instrument) and associated cartridge currently under development. A single test cartridge with multiple assays will be compared with Light Transmittance Aggregometry (LTA) within a clinical setting using blood samples. Analytical performance will be compared between these assays. The outcome of this evaluation will be used to demonstrate baseline performance and support the design and development of the Saturn analyzer and optimization of the associated algorithm.
Postoperative bleeding in cardiac surgery is a frequent complication, and cardiac surgery utilizes 15-20% of the national blood supply. Packed red blood cells (pRBCs) are associated with worse short and long term outcomes. For each unit transfused, there is an additive risk of mortality (death) and cardiac adverse events. Despite current guidelines and numerous approaches to bleeding reduction, \>50% of the patients undergoing cardiac surgery receive transfusions. Acute normovolemic hemodilution (ANH), a blood conservation technique that removes whole blood from a patient immediately prior to surgery, could be a valuable method to reduce transfusion in complex cardiac surgery. At the University of California, Los Angeles (UCLA), ANH is routinely utilized in patients who refuse allogenic blood transfusions such as Jehovah's Witnesses. ANH has been shown to be safe with minimal risk to patients. ANH has been studied in simple cardiac surgery, such as coronary artery bypass grafting, however it has not been studied in complex cardiac surgery, such as aortic surgery and adult congenital heart disease. ANH has been demonstrated to reduce pRBC transfusion in lower risk cardiac surgery without any significant complications. Complex heart surgery utilizes more blood products. This study could identify the benefits of ANH in a higher risk surgical group.
The goal of this clinical research study is to learn if a surgical procedure called an extraperitoneal laparoscopic lymphadenectomy followed by chemotherapy and tailored radiation therapy can help to control the disease for a longer time than standard-of-care chemotherapy and whole pelvic radiation therapy.
This is a single-arm, proof-of-concept trial to examine the feasibility, acceptability, and preliminary efficacy of the Ready for Recovery program, a 6-week collaborative care intervention to help prepare individuals for repair of aortic aneurysms.
The purpose of this study is to compare brain function after surgical circulatory arrest using either antegrade perfusion or retrograde perfusion.
The ascending aorta conducts blood from the heart to the rest of the body. The ascending aorta can become enlarged, and the risk of tearing and rupturing becomes higher with larger aorta. When the ascending aorta tears or ruptures, the risk dying is high even if surgery is done as soon as possible. Traditionally, when the ascending aorta gets above 5.5 cm, surgery is recommended to replace the aorta. However, this threshold is based relatively weak evidence, and sometimes patients with smaller aorta can tear or rupture. On the other hand, surgery carries its own risk as well. Since there are risk of waiting or doing surgery, there is currently no great support for either approach for patients with a smaller aorta. In the TITAN SvS trial, patients with an ascending aorta between 5.0 to 5.5 cm is assigned by chance to the early surgery group, in which they will undergo replacement of aorta, or the surveillance group, in which they will be closely monitored. The chance of dying or suffer tearing or rupture of aorta between the two groups will be compared. The result of the trial will guide future practice for patients with enlarged ascending aorta. This is a prospective, multi-centre randomized control trial that compares the all-cause mortality, aneurysm-related aortic events, rate of stroke, and quality of life for those patients undergoing early elective ascending aortic surgery to those patients undergoing surveillance. Patients referred for an ascending aortic aneurysm that meets the inclusion criteria will be randomized to the early elective surgery group or the surveillance group. Recruitment will end when the desired sample size is reached, and the patients will be followed for a minimum 2-year period. The primary objective of the trial is to compare the composite outcome of the all-cause mortality and incidence of acute aortic events between surveillance and elective ascending aortic surgery for patients with degenerative or bicuspid valve-related ascending aortic aneurysm after 2 years of follow up. The hypothesis is that the early surgery group will have a significantly lower all-cause mortality and incidence of acute aortic events at 2 years of follow up compare to the surveillance group. The result of this trial will provide evidence based guidance in the appropriate management of ascending aortic aneurysm based on the size criteria, and establish a large database for future investigations.
The purpose of this pilot study is to obtain both near valve and downstream flow characteristics, using 3D transthoracic echocardiography and 4D flow MRI respectively, in an existing patient population at Northwestern Memorial Hospital, to determine the hinge washout characteristics and downstream flow patterns of the On-X valve and compared to competing designs.
This is a prospective, randomized pilot study in patients undergoing Sugical Aortic Valve Replacement (SAVR) and Transcatheter Aortic Valve Replacement (TAVR) to estimate the incidence of reduced leaflet motion and assess the impact of perioperative anticoagulation on the incidence of reduced leaflet motion.
This is a prospective study designed to evaluate the structural and functional integrity of transcatheter or surgical bioprosthetic valves with multimodality imaging. The study further aims to confirm resolution of the early bioprosthetic valve thrombotic changes with anticoagulation.
The purpose of the clinical study is to prove that the heart valve device is safe, effective, and performs as intended.
Prospective, two academic center, non-randomized pilot, acute in-patient study correlating pre-operative imaging studies, intra-operative measurements and intra-operative balloon aortic valvuloplasty (BAV) in patients with degenerative aortic stenosis undergoing surgical aortic valve replacement (SAVR) to understand the requirements (device size and radial strength) of emerging percutaneous heart valve technologies in the treatment of aortic stenosis.
This study is designed to assess the feasibility of evaluating cerebral saturation during critical periods of deep hypothermia circulatory arrest and Selective Antegrade Cerebral Perfusion.
The goal of this randomized clinical trial is to compare single shot rectus sheath blocks of liposomal bupivacaine/bupivacaine mixture to bilateral rectus sheath catheters infused with ropivacaine (standard of care at our facility) in patients undergoing vascular surgery with an open mid-abdominal laparotomy incision. This study will examine the difference in the highest, lowest, average, and current pain scores reported at the end of 24-48 postoperative hours using the brief pain inventory-short form (BPI-SF). Participants will be randomized to either receive a single dose of liposomal bupivacaine/bupivacaine mixture intraoperatively at the end of surgery through bilateral rectus sheath blocks (LB/B group) or to receive the standard of care ropivacaine intraoperatively at the end of surgery through bilateral rectus sheath blocks with the insertion of bilateral RS catheter for continuous ropivacaine infusion plus repeated daily boluses (Catheter group; standard care). They will be assessed for a difference in postoperative pain scores, opioid consumption, hospital and PACU length of stay, patient's satisfaction, and quality of recovery. Additionally, we will examine the resources consumed by each intervention, including the medication cost (ropivacaine vs. LB/bupivacaine mixture), block and catheter supply, hospital length of stay, and anesthesia billing time.
Three-dimensional echocardiography has become a gold standard to assess right ventricular (RV) function, and investigators plan to use 3D transesophageal echocardiography to assess RV function in 3 types of aortic valve replacement (AVR): surgical AVR (SAVR), mini-sternotomy AVR (mini AVR), and transcatheter AVR (TAVR).
To establish the safety and effectiveness of the Edwards SAPIEN 3 Transcatheter Heart Valve (THV) in patients with severe, calcific aortic stenosis who are at low operative risk for standard aortic valve replacement.
The purpose of this study is to compare the therapeutic strategies of rate control versus rhythm control in cardiac surgery patients who develop in-hospital postoperative atrial fibrillation or atrial flutter (AF). In patients who develop AF during hospitalization after cardiac surgery, the hypothesis is that a strategy of rhythm control will reduce days in hospital within 60 days of the occurrence of AF compared to a strategy of rate control.
This registry is designed to monitor the real world clinical performance and safety of the V8 device used to perform balloon aortic valvuloplasty (BAV). Additional analyses or calculations may be obtained from the imaging or evaluations already performed per the sites' standard of care
The purpose of this study is to demonstrate faster time to extubation after arrival in the cardiothoracic intensive care unit (ICU) in patients undergoing isolated coronary artery bypass grafting (CABG), AVR and AVR/CABG combination who receive Sugammadex as compared to placebo.
This is a pilot study in which we will aim to demonstrate successful execution of the imaging protocol and to make observations regarding the calcification activity as measured by 18F-NaF PET/CT and any correlation to 1) valve age and valve type, and 2) subsequent degeneration of aortic valve bioprostheses based upon clinical, echocardiographic and CT parameters. Additionally, the data will serve as preliminary data to plan a larger study to investigate study objectives.
To demonstrate non-inferiority of the Trilogy Transcatheter Heart Valve (THV) System compared with surgical aortic valve replacement (SAVR) for treatment of subjects with clinically significant native aortic regurgitation (AR)
The investigators are conducting a pilot study to compare cognitive outcomes among Veterans with severe aortic valve stenosis who are scheduled to undergo either aortic valve replacement.
In the spirit of improving patient safety and quality of healthcare in our region, the Dallas-Fort Worth Hospital Council Education and Research Foundation (Foundation) and Baylor Research Institute sought and obtained federal funding support (AHRQ grant) to develop an Abdominal Aortic Aneurism (AAA) surgery registry in North Texas. Participating centers will directly benefit from this project and will have access to a de-identified version of the registry data through their collaboration. These data may be used for quality improvement initiatives and/or to conduct your own research. In summary, this effort represents a substantial investment (with no costs to facilities) in improving outcomes for patients with AAA.
This is a prospective, non-randomized, single center, data collection study of patients treated with open surgical repair (OR) for complex aortic aneurysms (CAAs).
The objective of this study is to assess the safety and effectiveness of the Cordis Bilateral AAA device and its Delivery System compared to open surgical repair for the treatment of Abdominal Aortic Aneurysm (AAA).
The study protocol is a randomized trial of standard of care therapies for severe aortic stenosis (AS) in patients with a bicuspid aortic valve (BAV). Namely, the therapies to which patients will be randomized will be transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR), in patients deemed clinically suitable for both following heart team review. The purpose of this study is to compare the safety and efficacy of Transcatheter Aortic Valve Replacement (TAVR) versus Surgical Aortic Valve Replacement (SAVR) for treating patients with severe aortic stenosis (AS) who have a congenital bicuspid aortic valve (BAV) anatomy. Patients with BAV anatomy have been under-represented in previous trials and this study might provide important information to help guide future treatment options. The study patients will be followed with standard of care procedures for 10 years.
The use of the IABP, in addition to standard care, in high-risk cardiac patients undergoing major noncardiac surgery is feasible and may result in improved perioperative outcomes at 30 days compared with standard care alone, while maintaining acceptable safety with respect to vascular accesss-related complications.
A multi-center, randomized clinical trial that will compare endovascular repair with standard open surgery in the repair of abdominal aortic aneurysms (AAA). Long and short-term results as well as the cost and quality of life associated with these two strategies for AAA repair will be compared.
Aortic occlusion (AO) for trauma has traditionally been accomplished by supra-diaphragmatic clamping of the descending thoracic aorta via emergent thoracotomy or as an initial step during laparotomy.
This is a prospective, randomized study that is studying the rate of red blood cell (RBC) transfusion rates after planned heart (cardiac) surgery. The study will be conducted at Barnes-Jewish Hospital. Cardioplegia refers to the method of stopping (arresting) the heart in order to perform heart surgery. However, cardioplegia has also come to refer to the solution to achieve cardiac arrest as well as the machinery in which to deliver the solution. This study will investigate our current Standard Cardioplegia (diluted 4:1 blood cardioplegia) versus Microplegia (undiluted blood cardioplegia) to determine if Microplegia reduces peri-operative blood transfusion rates as compared to Standard Cardioplegia. All forms of cardioplegia will be delivered using the MPS2 Microplegia delivery machine by Quest Medical, Inc. Patients will be randomized to receive undiluted microplegia or standard 4:1 cardioplegia. The patient and the surgeon will be blinded to the randomization. Patients will be followed for 30 days post-operatively (or until their initial standard of care post-operative follow up visit with cardiac surgery if that appointment falls outside of the 30 day post-operative window) for the development of any adverse events as well as documentation of blood products given. We will draw one tube of blood for troponin levels at four time points; 1 draw before surgery (this may be done during the intraoperative period), and 3 draws post-operatively: ICU arrival, 12 hours post-ICU arrival and 24 hours post-ICU arrival. This is to closely monitor the patient for any heart tissue injury.