65 Clinical Trials for Various Conditions
The primary objective of the PACCS trial is to assess if early invasive hemodynamic assessment and ongoing management with a PAC in patients with cardiogenic shock due to acutely decompensated heart failure (AHDF-CS) is associated with lower in-hospital mortality risk compared to the current standard of care with no or delayed PAC assessment.
Investigators will conduct a pragmatic randomized trial to investigate the non-inferiority of restricted use of invasive arterial lines compared to standard arterial line use.
This Study will compare the accuracy of the ECOM Plus Endotracheal Cardiac Output Monitor (ECOM) without the use of the arterial pressure waveform from the arterial line to 1) the current clinical standard of cardiac output measured by intermittent room temperature bolus thermodilution using a PAC, 2) the current ECOM System with the use of the arterial blood pressure waveform from a radial arterial line and 3) the Flo-Trac® System.
This study will include the placement of a pressure volume (PV) loop catheter in the right atrium of patients undergoing left ventricular assist device (LVAD) placement and measure relevant PV loop data. Transesophageal echocardiography (TEE) and pulmonary artery (PA) catheter parameters as comparators to the PV loop will be recorded.
Umbilical artery catheters (UACs) are associated with significant morbidity in preterm neonates however are necessary for the management of this high risk population. UACs have been linked to serious adverse events (SAEs) including arterial thrombosis, necrotizing enterocolitis, limb ischemia, and renal failure. Resonance Raman Spectroscopy (RRS), raman for short, is a technology that utilizes vibrational spectroscopy, rather than absorbance spectroscopy, to determine the oxyhemoglobin concentration in tissues. In this prospective, observational study, daily measurements of StO2 of low birth weight neonates using raman spectroscopy will be correlated with UACs.The study team hypothesizes that raman can detect changes in peripheral tissue oxygenation in the ipsilateral extremity to the UAC and that raman is more sensitive at detecting changes in peripheral tissue oxygenation then common metrics used to monitor neonatal hemodynamics. If successful, this study would demonstrate that raman can be used as an early marker of tissue oxygen deprivation in neonates with UACs and maybe used to guide management in other clinical scenarios where StO2 is affected.
The purpose of this study is to compare intraoperative papaverine plus heparin to heparin alone for prevention of arterial spasm and maintenance of patency of peripheral arterial catheters during surgery in pediatric patients. The hypothesis is that periodic, intraoperative small-volume boluses of diluted papaverine plus heparin in peripheral arterial catheters of pediatric patients will prevent arterial spasm and help maintain patency of arterial catheters during general anesthesia.
Even slight reduction in serious complications related to blood pressure management would easily justify the cost and relatively rare complications consequent to arterial catheter insertion. However, it seems unlikely that major outcomes will be improved by the presumably slight difference in hemodynamic control resulting continuous blood pressure measurement rather than measurements at 2-5-minute intervals. There is considerable variation in practice and no clear consensus whether arterial lines should be placed or not, especially in ASA 2 patients undergoing major non-cardiac surgery or ASA-3 patients undergoing moderate to major non-cardiac surgery. Clearly, if there is no benefit to outcome, arterial lines, which are invasive and costly, should not be placed routinely. The investigators therefore propose to test the primary hypothesis that use of arterial catheters decreases the risk of a collapsed composite of in-hospital mortality, re-admissions, MINS, AKI, stroke, respiratory and wound healing and gastro-intestinal complications after non-cardiac surgery. Secondarily, the investigators propose to test the hypotheses that arterial catheter use: 1) decreases the duration of hospitalization; 2) increases blood gas, electrolyte, and coagulation testing; 3) increases induction-to-incision time; and, 4) increases cost-of-care (supplies,, blood tests, and induction-to-incision time).
Arterial catheterization is frequently performed on critically ill patients for invasive blood pressure monitoring and/or frequent blood draws, especially arterial blood gas analysis. The distal part of the radial artery (wrist) is the preferred access site. The potential complications of the procedure are mostly minor and comprise temporary occlusion of the radial artery (RA), hematoma, local infection or bleeding from the puncture site. Major complications including vessel aneurysm or occlusion with threat to hand viability are rare. The standard approach to catheterization is "blind" puncture of the RA while locating its pulse by palpation, followed by threading a 20 Gauge (20G) angio-catheter into the vessel. Alternatively ultrasound can be used to locate the vessel and guide needle insertion. To our knowledge, four prospective randomized trials (PRT)5-8 comparing palpation with ultrasound-guided RA catheterization have been conducted so far and one meta-analysis looked at the pooled data obtained from these. The results showed that ultrasound guidance increased the first-attempt success rate at RA catheterization by 71% compared to palpation. The use of ultrasound also significantly reduced the time to successful catheterization, the number of punctures as well as the amount of catheters required per procedure. None of the prior randomized trials has been conducted in an ICU setting and in three out of the four studies the arterial lines were placed in patients undergoing elective surgery. The investigators hypothesized that ultrasound could improve first attempt success rate while placing arterial catheters in an ICU setting. Ultrasound may also reduce total time to successful insertion and reduce complications. The investigators plan to randomize patients to either a palpation technique or ultrasound guided catheter insertion and record the above outcomes.
The purpose of this study is to compare cardiac output results obtained using the thermodilution push technique with the Pulmonary Arterial Catheter (PAC) to the predicted cardiac output results obtained from the non-invasive FloWave™ 1000 device.
Skill with pulmonary artery catheter (PAC) waveform interpretation is inadequate among physicians and nurses. We, the investigators at Massachusetts General Hospital, have developed a web-based computer program to assist physicians and nurses in PAC waveform interpretation. We will study the effectiveness of this program on improving the interpretation of waveforms on a computer-based test.
Prior investigators have evaluated the use of 2-octyl cyanoacrylate (glue) as a method to secure a variety of venous catheters including central/peripheral lines. There is a paucity of research evaluating the use of glue for arterial catheters. The investigators conducted a pilot study to test the null hypothesis that there would be no difference in failure rates between radial arterial lines (r-a-line) secured with glue vs. suture.
This study is a multicenter, observational, post-marketing, registry study designed to track the safety and performance of the RenovoCath® device and assess survival outcomes in patients diagnosed with solid tumors who are treated with localized intra-arterial (IA) delivery of therapeutic agents to solid tumors using the RenovoCath® catheter.
The goal of this observational study is to find out if researchers can measure oxygen consumption in the body without having to draw blood from lines in arteries and central veins. Participants will undergo measurements of arterial blood oxygen saturation using both finger and neck pulse oximeters.
The purpose of this study is to validate cardiac output and stroke volume derived from Vitalstream against Gold Standard measurements obtained using thermodilution. The Vitalstream device is a continuous noninvasive physiological monitor (Caretaker Medical LLC, Charlottesville, Virginia, further referred to as "CTM") provides heart rate, continuous noninvasive blood pressure (BP), respiratory rate, stroke volume and cardiac output.
To compare a noninvasive and continuous radial artery blood pressure measurements utilizing ViTrack (developed by Dynocardia) to the standard of care radial artery catheterization, in patients undergoing surgery or those who are being cared for in the intensive care unit
Arterial catheterization is painful and is associated with patient stress and anxiety. Analgesia is usually provided by subcutaneous injection of local anesthetic. An alternative is topical anaesthesia, such as Rapydan which is a novel topical anesthetic patch containing 70 mg each of lidocaine and tetracaine. We therefore tested the hypothesis that Rapydan patch analgesia is non-inferior to subcutaneous local anesthetic.
The aim of this research is to apply cardiac tissue characterization in order to assess left ventricular function in cardiac surgical patients pre and post cardiopulmonary bypass. The procedures to be used include a retrospective review of transesophageal images obtained during conventional intraoperative transesophageal echocardiography (TEE) for cardiac surgery, as well as a secondary analysis with Tissue Doppler. The results will be compared with hemodynamic data obtained from a pulmonary artery catheter (PAC).
The purpose of the study is to determine if the less invasive monitors are as reliable for measuring heart function in patients undergoing liver transplantation as the more invasive pulmonary artery.
The purpose of this study is to determine if alteplase is effective in dissolving a clot in a catheter in a large vein (central venous line or PICC line) or artery in infants less than 6 months of age.
Each year in the United States more than 30,000 children are admitted to intensive care units. The majority of these children have some degree of heart instability during their stay, yet there is currently no routine way to measure the actual amount of blood that the heart pumps. The ability to measure the amount of blood that the heart pumps accurately and easily at frequent intervals would be very helpful to the doctor caring for these children because many of them have poor heart function as a result of their illnesses. Current techniques used in adults to measure output of the heart are either not readily transferred to children or demand difficult invasive procedures. Because of this, the amount of blood that the heart pumps cannot be measured with enough frequency to help guide care. Despite this reality, accurate measurements of the amount of blood that the heart pumps in these patients at crucial points in their illnesses would allow for more accurate use of potentially harmful procedures and could possibly improve the outlook for these children. Likewise, being able to correctly measure blood volume could provide a better way to estimate the pressure on the heart and improve treatment. The purpose of this research study is to compare the accuracy of doctor estimates of heart output, and establish the usefulness of central blood volume measurements by PCOM (pediatric cardiac output measurements), a less invasive procedure
The goal of this prospective randomized double-blind study is to determine if an ultrasound guided peri-arterial injection of local anesthetic (LA) superomedially the femoral artery via peripheral nerve catheter reverses ischemic hypertension associated with prolonged lower extremity tourniquet time.
To monitor the cardiac post-op patient population with both the pulmonary artery catheter (PAC) and the Caretaker monitor, which will seek to validate the Caretaker monitor against continuous CO via the PAC. Up to a third of post-operative cardiac surgery patients develop cardiac arrhythmias such as atrial flutter and atrial fibrillation. Secondary analysis will be performed on the collected data to assess the Caretaker monitor's agreement with the PAC during periods of arrhythmia. Successful completion this study will provide clinical validation of the Caretaker monitor in one of the most hemodynamically challenging patient populations (post-cardiac surgery patients in the ICU), including during arrhythmias. The Caretaker monitor is most beneficial as it is non-invasive, is a minimal risk device, and for this protocol will not be utilized to make treatment decisions for the study subject. This device also does not project energy into the subject.
The purpose of this registry study is to gather real world standard of care (SOC) data on the safety and performance on the Roxwood Medical catheter devices in the treatment of stenotic lesions and CTO.
The specific aims of the project are as follows: To determine whether catheter-based revascularization procedures improve functional capacity and quality of life among patients with intermittent claudication. To investigate whether improvements in walking ability result in a less sedentary lifestyle and improvement of the cardiovascular risk profile.
This investigational device exemption (IDE) study is to assess the safety and effectiveness of the Shockwave Coronary Intravascular Lithotripsy (IVL) System with the Shockwave C2+ 2Hz Coronary IVL Catheter to treat de novo, calcified, stenotic, coronary lesions prior to stenting.
Due to discontinuation of the Codman C3000 pump, an alternate device is necessary to continue serving patients in need of hepatic arterial infusion chemotherapy. This study aims to test the safety of hepatic artery infusion pump placement, a standard surgical procedure, and intraarterial chemotherapy initiation with the standard medication floxuridine (FUDR), using the Medtronic Synchromed II pump combined with the Codman arterial catheter in patients with unresectable (not removable by surgery) liver metastases from colorectal cancer and unresectable intrahepatic cholangiocarcinoma. This study will determine if complication and pump loss rates will be similar to previously published rates for the Codman system.
Prospective, single-center, single-arm, non-randomized study to assess the safety and efficacy of the FLEX Scoring Catheter in patients with atherosclerotic peripheral artery disease in the superficial femoral and popliteal arteries.
The objective of this trial is to determine the role of renal sympathetic denervation in the prevention of atrial fibrillation (AF) recurrence in patients with hypertension for whom a catheter-based AF ablation procedure is planned. Patients will be randomized to either AF catheter ablation (usual therapy) or AF catheter ablation plus renal sympathetic denervation.
The present study relates to a new approach to coronary artery and coronary artery by-pass graft imaging, and more particularly to computed tomographic angiography following an aortic root injection of a low amount of contrast (up to 30 cc) via a percutaneously placed catheter (Vanguard DX, Medrad Inc.) positioned in the aortic root. The objective of the study is to show the feasibility of Coronary artery CTA using aortic root injection of contrast compared to the standard invasive cardiac catheterization.
Below-the-Knee Interventions for Limb Salvage: Use of Multifunctional Angioplasty Balloon Catheters ("BTK Multicath Registry") A non-randomized clinical registry This study is designed to obtain preliminary data on clinically relevant procedural variables during percutaneous below-knee artery revascularization procedures among consecutive patients treated with either the Finesse BTK Multicath® ("Finesse") or the standard of care using conventional angioplasty balloon catheters. This registry will enroll participants with a history of chronic limb threatening ischemia and below-knee arterial insufficiency who will be assigned to revascularization with or without use of the Finesse BTK Multicath. The registry is an acute study examining procedural data only. The primary endpoints of interest are the volume of contrast used for the intervention, overall procedure time, radiation dose, number of catheter exchanges during revascularization, and medical device supply costs. For the first phase 12 consecutive patients will be treated with the standard of care. For the second phase 12 consecutive patients will be treated with Finesse. 24 participants total Up to 5 study sites in the United States Initial anticipated enrollment: Q4 2024 Last anticipated enrollment: Q2 2025 Patients \>=18 years old with documented history of unilateral chronic limb threatening ischemia due to below-knee arterial insufficiency with angiographic runoff in the foot and limited arterial insufficiency above the knee 1. Contrast volume administered during the revascularization portion of a procedure. 2. Number of catheter exchanges during revascularization 3. Fluoroscopy time 4. Radiation dose during revascularization 5. Procedure time post-enrollment 6. Equipment costs 7. Reduced use of supplies 8. Technical success 9. Safety/Major Adverse Peripheral Events On-treatment sample Intention-to-treat