6 Clinical Trials for Various Conditions
Evaluate the safety of the MynxGrip™ extravascular sealant for common femoral vein closure following both diagnostic and interventional procedures as assessed by clinical and imaging criteria.
The Azurion R4.0 is developed by Philips Medical Systems Nederland B.V., a Philips Healthcare company. The Azurion is an interventional X-ray system which is used for live X-ray imaging during invasive cardiac procedures. The proposed Azurion R4.0 includes new x-ray image postprocessing (Xres5) compared to its predecessor, which was equipped with ClarityIQ image post-processing (Xres4). Azurion R4.0 is a cleared device for EU-MDR regulated countries, submission for FDA510K clearance in the US is pending. Sites in the US will only be activated in the study after FDA clearance. This is a prospective, randomized, unblinded, comparative, international, multi-center clinical investigation. Randomization will be 1:1 between Xres5 and ClarityIQ (Xres4). Stratification will be performed per site on intended procedure type (based on clinical presentation) and patient BMI. Primary objective is to demonstrate that in coronary procedures, Xres5 can reduce overall patient radiation dose compared to the current ClarityIQ without affecting procedural performance. It is expected that 824 subjects are necessary to collect sufficient data for the evaluation of the objectives of this clinical study. The enrollment period is expected to last for 12 months. The study will be executed in Spain, Czech republic, Denmark and the US.
The purpose of the Registry is to provide continuing evaluation and periodic reporting of safety and effectiveness of Medtronic market-released products. The Registry data is intended to benefit and support interests of patients, hospitals, clinicians, regulatory bodies, payers, and industry by streamlining the clinical surveillance process and facilitating leading edge performance assessment via the least burdensome approach.
To determine if ultrasound measurement of renal and carotid arterial resistive indices are associated with post-cardiac surgery acute kidney injury.
Coronary artery disease (CAD) is caused by a narrowing of the blood vessels that supply blood and oxygen to the heart. Balloon angioplasty and stent placement are two treatment options for people with reduced heart function caused by CAD. This study will use magnetic resonance imaging (MRI) procedures to evaluate heart function over time in people with CAD who have undergone a balloon angioplasty or stent placement procedure.
This medication is used for procedural sedation and sedation for diagnostic imaging. The purpose of this study is to find out what happens to pentobarbital in the body after it is given to children who have had heart surgery.