19 Clinical Trials for Various Conditions
The goal of this clinical trial is to compare two types of surgical fixation in patients with specific kinds of distal femur fractures. The main questions it aims to answer is which operation for distal femur fractures is better for efficient return to work and everyday activities.
Supracondylar femur fractures in the geriatric population present a unique challenge to the orthopaedic surgeon both in terms of fixation, healing, and final extremity axial alignment. Pulsed dosing of parathyroid hormone derivatives (Forteo) has been shown to increase bone mass, and several studies in Europe have demonstrated its benefit as an adjuvant for fracture healing. Abaloparatide represents a new compound which similarly offers great potential for accelerating fracture healing, especially healing associated with callous formation. This is a randomized, double blind placebo-controlled trial to compare a group of patients being treated for supracondylar distal femur fractures who receive abaloparatide (n=38) with a control group of patients who receive a placebo (n=38).
In order to assess the rate and mode of failure cases observed in patients with distal femur fractures treated with a distal femur plates, anonymized radiographs from those patients will be collected retrospectively. All available images will reviewed by an expert review board in regards to fracture classification, implant and surgery details, quality of initial reduction and plate positioning as well as the occurrence of mechanical complications and the outcome in terms of fracture healing (if available). Additionally, age and gender as basic demographical data will be collected in a de-identified way..
This study is designed to examine if immediate weight bearing on a distal femur fracture fixed with a primary locking plate, either a distal condylar locking plate or a LISS (less invasive stabilization system), is safe and promotes more rapid fracture healing than partial weight bearing, which is standard of care.
The investigators will be looking at geriatric distal femur fractures. The investigators will prospectively enroll these patients and allow patients to either weight bear as tolerated or limit their weight bearing post operatively. The investigators will evaluate functional outcomes.
The objective of this study is to document callus formation and healing of fractures stabilized with locking plates utilizing modern MotionLoc screws that provide controlled axial micro-motion to actively promote fracture healing.
The investigators are doing this research study to look at how distal femoral fractures (knee bone break) heal. In this study, the investigators will use Radiostereometric Analysis (RSA) to look at how the pieces of femur bone move as the bone heals. RSA is a special x-ray that uses radiographs to measure very small movements in the bone over time. The question that will be answered by this study is whether RSA can be used as a tool to monitor fracture healing.
Internal fixation of femur fractures improves alignment and provides stability to the bone and the surrounding soft tissues. This generally allows for early motion of the adjacent joints; thus maximizing overall function of the limb. Open reduction and internal fixation with plates and screws is the standard method that has been used in the treatment of distal femoral fractures. One common traditional method of internal fixation is the 95-degree angled blade plate. Recent advances in technology for distal femur fractures include the LCP™ Condylar Plate. This implant differs from the blade plate, because the LCP offers multiple points of fixed angle contact between the plate and screws in the distal femur. The introduction of plates with the option of locked screws has provided means to increase the rigidity of fixation in osteoporotic bone or in periarticular fractures with a small distal segment, and the LCP may be technically easier to apply than the blade plate. To the investigators' knowledge, there have been no published clinical or biomechanical studies specific to the LCP Condylar Plate, although the early results of LCP implants for other fractures are promising. The investigators believe that locked plating represents a valuable advancement in fracture treatment. However, the limitations of this new technology and the indications for its use have not been completely elucidated. Furthermore, the cost of the new technology is approximately seven times more than the traditional treatment. This is a randomized, prospective, multi-center study to compare the blade plate and the LCP in the distal femur. All patients 16 years of age or older, regardless of race or gender, with a supracondylar fracture of distal femur will be considered. Whether patients are treated with a blade plate or/and LCP, they will be receiving standard orthopedic care for their injury. Neither of these methods currently places a patient at increased surgical or post-surgical risk for problems with infection, nonunion, malunion, or other complications. Because of the study, early and late complication rates and functional outcomes after these treatments may be better defined, allowing for optimization of care of people with these injuries in the future. This should reduce not only direct and indirect costs to the individual, but also costs to society.
This study looks at two (2) types of surgical treatments and hopes to answer the question, "which is the best way to surgically treat a distal femur fracture?" Both procedures being studied are standard of care (used routinely) and use FDA approved devices. All medical and surgical treatment will be the same for participants as non-participants.
Supracondylar femur periprosthetic fractures about a total knee arthroplasty (TKA) are a catastrophic and challenging complication of TKA and unfortunately are increasing in incidence. Fixation of these fractures can be challenging due to altered anatomy for the TKA and the presence of the metallic femoral component and have a relatively high complication rate. As a result, some surgeons elect to treat these fractures with a distal femur replacement total knee arthroplasty (DFR). The purpose of this study is to prospectively evaluate periprosthetic femur fractures treated with ORIF or DFR and compare various outcomes measures (Get up and go times, KOOS Jr score)
The investigators overall study objective is to determine the difference in outcomes for patients over 60 years of age with a displaced distal femur fracture treated with dual distal femur implants (dual plate or IMN/plate) vs. a single distal femur implant (plate or IMN).
This is a two-year study proposal to assess feasibility of MWeST (Mobile Weight-Support Therapy) implementation after geriatric fracture and its effects on functional and patient-reported outcomes. The goal of this study is to improve mobilization of geriatric lower extremity trauma patients, with the aim of improving overall functional and patient-reported outcomes while decreasing complications and readmissions. Almost 50% of the adult population in the United States has osteopenia or osteoporosis, with over 2 million fragility fractures per year and a projected $25 billion in costs by 2025. These patients are at high risk for readmission due to complications, and at increased risk of mortality with these complications. Sarcopenia, a generalized loss of skeletal muscle associated with aging, has also been associated with increased disability and increased risk of future fracture in these patients. The investigator's study aims to assess the value of weight-support therapy for geriatric patients with lower extremity trauma in improving their overall risk of future injury and disability.
The overall objective of this study is to compare outcomes following early advanced weight bearing (EAWB) using the AlterG antigravity treadmill versus standard of care physical therapy for adult patients with lower extremity periarticular injuries.
The purpose of this study is to evaluate the performance of Dynamic Locking Screws (DLS) used to stabilize the shaft component of distal femur fractures in comparison to standard locking screws (SLS). The hypothesis is that DLS will lead to better functional outcomes (WOMAC score) due to increased and more symmetrical callus formation and fewer non-unions.
Analgesic drug study that will compare pain outcomes of opioid analgesia and opioid-free analgesia in post-operative orthopedic patients.
Comminuted metaphyseal fractures (OTA classification A2/3 and C2/3) of the distal femur and distal tibia are difficult to treat and typically have more complications than other metaphyseal fractures. Delayed union, nonunion and need for secondary bone graft procedures are frequent outcomes. These A2/3 and C2/3 fractures of the distal femur and distal tibia treated with locked plates often have a critical sized fracture gap (poorly organized cortical pieces many of which are stripped of soft tissue). Optimal management strategies that minimize both fracture healing time and complication rates remain controversial. Primary bone grafts or early secondary bone grafts have been recommended for these comminuted open fractures, but have not been studied as the primary end point in a randomized trial. There is a need to study primary bone grafting during open reduction and internal fixation (plating) of these difficult fractures, to determine if shorter healing time, and thus less need for reoperation, can be achieved. Hypothesis Acute autogenous bone grafting at the time of fixation will hasten clinical and radiographic union with a lower need for secondary procedures
This project consists of a prospective and retrospective case series design. Study candidates will include all patients 18 years or older, who were evaluated at UCSD and found to have a distal femur or femoral shaft fracture requiring surgical fixation. Patients who consent to study participation will recieve the RFN-advanced Retrograde Femoral Nailing System implant for fracture fixation. Data on functional status, healing rates, complication rates, and pain levels will be collected for each participant. After 3 years of data collection, investigators will analyze this data to provide further insight on the utility of this new design of retrograde femoral nails. Given the relatively high rate of complications, such as malalignment, with current femoral nail designs, it is imperative to evaluate novel systems to appropriately manage distal femur or femoral shaft fractures.
This research study is being conducted to examine the effect of two versus one fixation device for fixation of distal femur fractures.
This study is a randomized controlled trial comparing the use of two different surgical techniques--free-hand versus distal targeting jig-based for distal interlock screw--placement and their effects on total operative time and intraoperative radiation exposure.