17 Clinical Trials for Various Conditions
The purpose of this study is to compare outcomes of patients with an ankle fracture to those with ankle fracture-dislocations. We hypothesize that long-term clinical outcomes for patients sustaining ankle fracture dislocations are poorer than those without dislocation.
The Lisfranc ligaments are a group of ligaments that connect the bones of the middle portion of the foot to each other. The Lisfranc ligaments allow for a normal and stable range of motion and shape to the foot. In certain foot fractures where the Lisfranc ligaments are damaged, the constraint and stability it had given to the middle of the foot is lost. Attempted activity at the foot will result in pain and abnormal motion. If injury to the Lisfranc ligaments is left untreated, the eventual end result is foot arthritis and deformity. The current standard orthopaedic treatment of foot fractures with Lisfranc ligament injuries is surgery. The foot fractures are fixed with metal screws. The Lisfranc ligaments are fixed by compressing the space between the middle bones of the foot with steel screws. These screws allow for ligament healing. As the ligaments heal, the patient should not resume activity with the fixed foot too soon as the screw may break. Upon breakage, the ligament repair may fail and the screw is now difficult to surgically remove. Regardless of breakage, a second surgical procedure is often recommended to remove the steel screw 6 months after foot surgery. This allows for a complete return of normal foot range of motion, but at the cost of a second surgical procedure. The investigators hypothesize that absorbable screw fixation of the Lisfranc ligaments does not yield significant differences in postoperative foot stability, ligament function, and symptoms when compared to steel screw fixation. In addition, absorbable screw fixation of the Lisfranc ligaments offers the advantage that a second surgical procedure to remove the screw is not necessary.
The objective of this study is to collect and evaluate long-term clinical outcomes data in order to better understand the safety and performance of the Equinoxe Proximal Humerus Fracture Plates over time. This study will follow subjects for a period of up to 10 years post-surgery.
The purpose of this study is to help determine if a static stretching brace in addition to physical therapy decreases the incidence of secondary operations, increases range of motion, and individual patient function.
The purpose of this study is to determine the efficacy of ultrasound in diagnosing the presence or absence of extremity fractures or dislocations. Hypothesis: Can ultrasound be used as an accurate and effective method for determining the presence or absence of extremity fractures or dislocations? Is there a difference in amount of pain experienced prior to and after the ultrasound?
PrEvention of posttraumatic contractuRes with Ketotifen 2 (PERK 2) is a Phase III randomized, controlled, double blinded multicenter trial with 3 parallel groups (Ketotifen 2 mg or 5 mg or lactose placebo twice daily orally for 6 weeks) and a primary endpoint of elbow extension-flexion range of motion (ROM) arc at 12 weeks post-randomization.
The goal of this randomized controlled trial is to determine if accelerated flap coverage compared to standard flap coverage timing leads to improved infection-related complications in patients with open fractures and/or dislocations below the knee. Eligible patients will be randomized to receive either a flap within a goal of 72 hours of injury or standard of care flap timing for the institution. The primary outcome will be a composite outcome to evaluate clinical status 6 months after randomization. Components of the composite outcome will be hierarchically assessed in the following order: 1) all-cause mortality, 2) amputation related to injury, 3) re-operation for infection and/or flap complication (flap compromise, partial and/or complete flap failure), and 4) days in hospital, defined as days in an acute in-patient hospital (i.e., not rehab or nursing facility).
The purpose of the study is to evaluate the ability of the Fibulink Syndesmosis Repair System to maintain reduction of the ankle syndesmosis. Appropriate reduction of the syndesmosis is critical due the changes in tibiotalar contact pressure observed in cadaveric studies.6,7 Malreduction and instability of the distal tibiotalar joint can lead to chronic instability, increased articular damage and ultimately degenerative arthritis.7,8 Medial to lateral translation of distal tibia and fibula of 2 mm or more has been considered pathologic.9 Earlier biomechanical study demonstrated the Fibulink system is superior in maintaining displacement of less than 2 mm.4 Given the improved strength, we also look to evaluate the outcomes of initiating full weight bearing (100%) with Controlled Ankle Motion (CAM) boot at 4 weeks postoperatively. One of the big limitations for trans-osseous screw fixation is delayed weight bearing due to risk of screw breakage.1 Suture button technique allowed for early weight bearing with average of 6 weeks postoperatively using TightRope.2,10-12By initiating full weight bearing (100%) with CAM boot at 4 weeks postoperatively, this would be a significant improvement in current clinical practice.
Hypothesis There is no difference in the incidence of pin tract infection and pin loosening in case of lower extremity external fixators when self-drilling schanz pins are used with or without pre-drilling. Primary Objective The primary objective is to determine whether pre-drilling holes for external fixation pin insertion is superior to not pre-drilling holes for external fixation pin insertion in regards to the incidence of pin tract infection and pin loosening. Secondary Objective If any difference is found between the two techniques then, we will quantify and qualify those differences. The incidence of pin site infection and pin loosening in general will be determined and will also be stratified for site and size of pin. An attempt to identify risk factors for pin site infection will be made by observing the effect of secondary prognostic factors like mode of injury, diabetes, smoking, compartment syndrome, peripheral vascular disease, neurovascular injury. Interobserver reliability of the grading system for pin infection will also be determined.
The main objectives of this study are to confirm the long-term safety, performance, and clinical benefits of the G7 Freedom Constrained Vivacit-E Acetabular Liners in primary and revision total hip arthroplasty.
This study is a global, multi-center, prospective, non-controlled, non-randomized, post-market clinical follow-up study. The main objectives of this study are to confirm the long-term safety, performance, and clinical benefits of the G7 Dual Mobility Acetabular System when used with the Vivacit-E or Longevity polyethylene hip bearing and instrumentation in primary total and revision (total) hip arthroplasty
The purpose of this study is to determine if the utilization of Ischemic Pre-Conditioning 24-hours prior to hip arthroscopy decreases patient's post-operative pain and opioid consumption.
A post market, non-randomized, multi-center, open-label,clinical study using survivorship to study the safety and efficacy of the Integra® TITAN™ Total Shoulder System 1.0 (TAS) when used for total shoulder arthroplasty.
The purpose of this study is to prospectively evaluate two FDA approved implant designs for the Tornier Reverse Shoulder arthroplasty. The small difference in design is the amount of offset each implant has. This offset may improve clinical outcomes in the patient population. There have been no clinical comparative studies between these two designs in the literature to date. We would like to follow these patients for two years after implantation of the reverse shoulder and evaluate their radiographs, pain scores, and shoulder functional scores. this would be the first randomized prospective single blinded study of its kind.
The SMR Stemless Reverse is intended for total, primary shoulder joint replacement by reducing pain and restoring shoulder articular mobility function. This is a prospective, multi-center, randomized, controlled trial to demonstrate non-inferiority of the SMR Stemless Reverse to the SMR Reverse Shoulder System. Patients with joint dysfunction who continue to experience significant symptoms despite an appropriate course of non-operative management are eligible. Patients will be considered enrolled into the study when an ICF has been signed, all inclusion criteria are met and no exclusion criteria are present including intraoperative exclusion criteria, and the patient is randomized into either the SMR Stemless Reverse (investigational) group, the SMR Reverse Shoulder System (control) group or is part of the roll-in population. Enrollment is expected to take approximately 24 months.
I hypothesize that absorbable screw fixation of the foot's Lisfranc ligaments does not yield significant differences in postoperative foot stability, ligament function, and symptoms when compared to steel screw fixation. In addition, absorbable screw fixation of the Lisfranc ligaments offers the advantage that a second surgical procedure to remove the screw is not necessary.
The purpose of this prospective clinical data collection is to document the performance and clinical outcomes of the ExploR® Modular Radial Head. This data collection effort will document the clinical outcomes of the radial head.