19 Clinical Trials for Various Conditions
This study collects information regarding your procedure. No changes will be done to your procedure and you are asked to consent for the use of your data in our database. You are being asked to be in this research study because you have a gastrointestinal lesion that needs to be removed. We remove these lesions endoscopically as part of the standard of care at Baylor St. Luke Medical Center, and we will be using a FDA approved device known as the Pathfinder Rigidization Overtube to assist with the removal of the polyp. This study is important because this is a relatively new procedure; although it is a part of your standard of care it is not done in many hospitals. We would like to document the outcomes and results of such procedures to continuously improve our standard of care.
For removal of large flat lesions of the gastro-intestinal tract injection of a solution under the lesion creates a "safety" cushion and protects from damage to the gastrointestinal tract wall. Various solutions are currently used, but some of them are easy to inject but quickly dissipate (normal saline),other solutions are more longer lasting (hydroxypropyl methylcellulose, hyaluronic acid, etc) but are very difficult to inject and can be expensive and not always available. The investigators performed previously animal experiments which demonstrated that blood is easy to inject and creates a protective cushion which lasts longer than other fluids which are currently used for protective cushion creation.
This is a prospective, multicenter, single-arm clinical investigation designed to evaluate the accuracy of the Gixam™ System in identifying subjects with colorectal adenomas compared to optical colonoscopy. Subjects arriving for a standard of care colonoscopy at the investigation site will be offered to participate in the study. Following an informed consent process, images of the subjects' tongue will be obtained with the Gixam™ System and a prediction score will be generated by the Gixam™ AI model. Subjects will thereafter proceed to their SOC colonoscopy, and the Gixam™ score will be compare with colonoscopy findings to evaluate its performance.
This is a longitudinal observational study on patients with gastrointestinal and related disease. The study will be conducted for at least 10 years, following each participant over time, as they either go through relapses and remissions, or progression of their disease.
After removing large polyps from the gastrointestinal tract, gastroenterologists close the new defect with devices to prevent complications like bleeding or the development of a leak. Commonly, this is done with a device called Overstitch, which allows the gastroenterologist to stitch the defect with an endoscope. A new device called X-tack has been developed to simplify endoscopic stitching. In this study, the new X-tack device will be compared to Overstitch when closing defects in the gastrointestinal tract. The two devices will be compared to see how long it takes to close a defect, as well as if there are any differences in complications like bleeding or infection.
The primary aim of this study is to evaluate the effect and impact of a technology which creates a virtual reality (VR), personalized representation of a patient's endoscopic findings in comparison our standard practice (SP). Our study will compare the level of knowledge, understanding and satisfaction the patient and family have between those receiving SP and those receiving both SP and VR.
The purpose if this study is to measure the sensitivity, specificity and accuracy of the Metabiomics Colon Polyp and Colorectal Cancer Assay for the non-invasive detection of colon polyps or colorectal cancer.
The primary objective is to determine the sensitivity and specificity of the Exact Colorectal Cancer (CRC) screening test for colorectal cancer, using colonoscopy as the reference method. Lesions will be confirmed as malignant by histopathologic examination. The secondary objective is to compare the performance of the Exact CRC screening test to a commercially available FIT assay, both with respect to cancer and advanced adenoma. Lesions will be confirmed as malignant or precancerous by colonoscopy and histopathologic examination.
The overall objective of this study is to obtain data to evaluate whether high-resolution imaging of the colon can assist clinicians in detecting dysplastic (precancerous) and neoplastic areas. This is a pilot study of a novel technology, a miniaturized microscope device which can be used during standard endoscopy to image the gastrointestinal epithelium. Theoretically, by visualizing superficial mucosal changes at a high-resolution and magnification, the investigators will be able to obtain optical images that can be used to guide endoscopic biopsy and polypectomy. This may foster the selective targeting of dysplasia/neoplasia, thereby improving diagnostic accuracy.
Standard white light endoscopy involves the passage of a thin, flexible camera into the colon from the anus. Although standard white light endoscopy can detect most polyps and precancerous areas in the gastrointestinal tract and colon, many studies have shown that even the most experienced doctors, under optimal conditions, can miss up to 15-25% of precancerous areas. Thus, there remains a clear need to develop new methods of improving standard white light endoscopy. We are investigating whether indocyanine green (ICG) can serve to highlight areas which are precancerous when the colon is visualized with a special cameral which shines fluorescent light. Information from other studies suggests that this ICG agent may help to visualize blood vessels flowing to precancerous areas in the colon. We are looking at the ability of ICG, in combination with an endoscope which shines fluorescent light, to visualize precancerous areas in the colon.
RATIONALE: Studying samples of tissue, blood, urine, stool, and other biological fluids from patients with cancer and from healthy volunteers undergoing colonoscopy or endoscopy may help doctors identify and learn more about biomarkers related to cancer. PURPOSE: This research study is looking at gastrointestinal biomarkers in tissue and biological fluid samples from patients and participants undergoing colonoscopy, endoscopy, or surgery.
The recently developed endoscopic Confocal probe microscopy system allows imaging of surface epithelium during ongoing endoscopy (upper and lower) with the potential of immediate diagnosis of various GI pre-malignant and malignant lesions. The purpose of this study is to determine if using this new Confocal probe system can find pre-cancerous abnormalities in the stomach and colon. Hypothesis: The confocal endomicroscopy images of colorectal lesions during the standard colonoscopies could help the classification in vivo of colorectal neoplastic and non-neoplastic lesions. This could direct further endoscopic interventions such as targeted biopsies of early colorectal cancer lesions and the endoscopic resection of such lesions during screening colonoscopies. Primary Aim 1. To determine the key confocal image features of neoplastic and pre-neoplastic colorectal lesions including flat and raised adenomatous polyps, intraepithelial neoplasia and cancer as well as benign lesions such as hyperplastic polyps and normal colonic epithelium and to estimate which morphologic features best distinguish neoplastic and non-neoplastic tissues. Secondary Aims: 2. To determine the initial sensitivity and specificity of confocal microendoscopy imaging for classification of adenomatous from hyperplastic polyps of the colon. 3. In this exploratory phase of the study to develop a library of confocal microendoscopic imaging characteristics of other GI pathologies such as: 1. Barrett's esophagus in comparison to Barrett's esophagus with dysplasia, and normal squamous esophagus. 2. Other encountered inflammatory and neoplastic conditions within the GI tract in which biopsy or removal of tissue would routinely be indicated. The second phase of the study will focus on establishing the sensitivities, specificities, accuracy of confocal images of colorectal lesions and other GI pathologies as well as inter-observer agreement and learning curve in interpretation of confocal images.
This is a multi-site comparative effectiveness randomized controlled trial (RCT) comparing annual fecal immunochemical testing (FIT) and colonoscopy for post-polypectomy surveillance among adults aged 65-82 with a history of colorectal polyps who are due for surveillance colonoscopy.
This is a retrospective and prospective multicenter registry to collect long-term data (1 year) on patients who have or will undergo Endoscopic resection such as EMR, ESD, EFTR, STER, etc. within the gastrointestinal tract for endoscopic treatment of early gastrointestinal neoplasms involving the resection of the superficial layers, mucosa and submucosa, of the tract wall. Subjects will be consented for medical chart review. The purpose of this retrospective and prospective registry is to assess long term data on efficacy, safety and clinical outcome of Endoscopic Resection within the gastrointestinal tract (1 year). The registry will evaluate efficacy, technical feasibility, clinical outcome, safety profile and overall clinical management through medical chart review. The procedures the investigators are evaluating are all clinically indicated and will not be prescribed to someone to participate in this registry study.
The CRC DRAW study will assess the sensitivity and specificity of the blood-based, Next-Gen CRC Screening Test for the detection of CRC.
The PREEMPT CRC study is a prospective multi-center observational study to validate a blood-based test for the early detection of colorectal cancer by collecting blood samples from average-risk participants who will undergo a routine screening colonoscopy.
Summary 1. Purpose and Objective: The purpose of this study is to test the feasibility of rapid acquisition of point of care 3D ultrasound in obtaining abdominal and/or pelvic images. The study will use a newly developed acquisition method and post-processing technique to create three dimensional image models of the abdomen and/or pelvis. 2. Study activities and population group. The study population will be a convenience sample of patients of any age presenting to the Emergency Department with complaints necessitating a clinical abdominal and/or pelvic imaging. The study intervention includes acquisition of research ultrasound images, which will not be used for clinical care, and comparison of these images with clinically obtained images. Other clinical data such as surgical and pathology reports will also be reviewed. 3.Data analysis and risk/safety issues. This is a pilot study intended to determine feasibility and to refine image reconstruction algorithms. Research images will be compared to clinical images. Comparison of research images with final diagnosis will also occur. The research intervention, an ultrasound exam, has no known safety risks. The only risk to subjects is loss of confidentiality. This study is observational, not interventional, because the experimental ultrasound will be performed in all subjects and will not be used in the clinical care of patients (consequently, will not have the opportunity to affect clinical outcomes). Experimental images will be reviewed after completion of clinical care and will not be provided to the clinicians caring for the subjects. The investigators are not measuring the effect of the ultrasound examination on the subjects' outcomes.
ME-APDS is a device (software-based with hardware) developed by Magentiq Eye LTD and intended to support the decision of the endoscopist on polyps which appear in the colonoscopy video during the colonoscopy procedure. This randomized two arm colonoscopy trial will mainly compare APC and APE between Magentiq Eye Assisted Colonoscopy (MEAC) and Conventional Colonoscopy (CC) in patients referred for either screening or surveillance colonoscopies.
This is an international, multicenter, study to evaluate the diagnostic performance of the CADx polyp sizing modality of the MAGENTIQ-COLO.