Treatment Trials

62 Clinical Trials for Various Conditions

Focus your search

COMPLETED
Hypotension Prediction Index to Predict Epidural-labor Analgesia Induced Hypotension
Description

The purpose of this pilot trial is to examine the feasibility and ease of use of monitoring by ClearSight in laboring and delivering patients with the intent to compare time-to-treatment of hypotension between conventionally monitored patients (Group CM) and those receiving HPI (Group CM + HPI) monitoring by ClearSight, in a population of healthy laboring women who receive epidural analgesia.

RECRUITING
ED90 of Epidural Bupivacaine With Lidocaine for the Initiation of Labor Analgesia
Description

To estimate the dose of bupivacaine required to achieve initial effective comfort in 90% of patients (ED90) via the epidural (DPE or EPL) technique in women undergoing labor after receiving a lidocaine "test dose"

ENROLLING_BY_INVITATION
Conversion of Labor Analgesia for Intrapartum Cesarean Delivery: DPE v CSE v Epidural
Description

As the dural puncture epidural (DPE) is increasing in popularity for labor analgesia, it is important to understand how it impacts outcomes in parturients. Prior studies have found epidural catheters placed via the combined-spinal epidural technique have greater success at surgical conversion for cesarean delivery than catheters placed via traditional techniques. The investigators aim to determine if epidural catheters placed by a DPE technique will also have an increased successful conversion for surgical anesthesia by conducting a retrospective review of all CD during the study period. If an association is found, this could be another benefit of DPE for labor analgesia.

COMPLETED
Comparing Effectiveness of CSE Versus DPE for Labor Analgesia
Description

The primary purpose of this study is to determine if there are differences in block quality between the CSE and DPE techniques for labor analgesia in parturients in active labor. We hypothesize that when compared to the CSE technique, the DPE technique will significantly improve block quality in this population and require fewer "top-ups" and catheter replacements.

Conditions
COMPLETED
Virtual Reality Compared to Nitrous Oxide for Labor Analgesia
Description

The purpose of this study is to determine if non-invasive distracting devices (Virtual Reality headsets) are non-inferior to conventional therapy (nitrous oxide) for addressing maternal needs during labor who desire non-epidural pain relief.

Conditions
TERMINATED
Drug Concentration and Volume on Adequate Labor Analgesia With PIEB
Description

Neuraxial labor analgesia is performed by the administration of a local anesthetic/opioid mixture in the epidural space. The delivery method is a combination of continuous infusion, provider-administered boluses and patient-administered boluses (patient controlled epidural analgesia \[PCEA\]) via epidural catheter. The anesthetic solution administered through the lumbar epidural catheter must spread cephalad in the epidural space to reach the T10 nerve roots and spinal cord, and must spread caudad to reach the caudal nerve roots in the epidural space. Epidural infusion pumps capable of delivering PIEB of local anesthetic with PCEA have become commercially available and many studies have attempted to assess the optimal parameter settings (including volume of programmed bolus, bolus interval, rate of bolus administration) to provide superior labor analgesia. Traditionally higher concentration local anesthetic solutions have been associated with increased motor blockade leading to a higher incidence of instrumental vaginal delivery. Several local anesthetic solutions with varying drug concentrations are available for labor analgesia and are used clinically in the United States. We plan to perform a randomized, controlled, double-blind study to test the hypothesis that patients whose labor analgesia is maintained using PIEB with low-volume bolus (6.25 mL) of a higher local anesthetic concentration solution (0.1% bupivacaine with fentanyl 2.0 mcg/mL) will require less supplemental analgesia (manual provider re-doses) than patients whose PIEB is delivered with a high-volume bolus (10 mL) of lower density local anesthetic solution (0.0625% bupivacaine with fentanyl 2.0 mcg/mL). The aim of this study is to evaluate the association between bolus volume and concentration of local anesthetic during maintenance of labor analgesia with programmed intermittent epidural bolus (PIEB) analgesia. The hypothesis of this study is: patients whose labor analgesia is maintained using PIEB with low-volume bolus (6.25 mL) of higher local anesthetic concentration solution (0.1% bupivacaine with fentanyl 2.0 mcg/mL) will have a longer duration of adequate analgesia (time to first manual re-dose request) than patients whose PIEB is delivered with a high-volume bolus (10 mL) of lower concentration local anesthetic solution (0.0625% bupivacaine with fentanyl 2.0 mcg/mL).

TERMINATED
Epidural Fentanyl for 2nd Stage Labor Analgesia
Description

This study is being done to investigate if there is more effective pain relief during the latter stages of labor and delivery when epidural fentanyl 100mcg is administered compared to epidural fentanyl 20mcg.

Conditions
COMPLETED
Presence of a Companion During Performance of Neuraxial Labor Analgesia
Description

The purpose of the study is to evaluate if maternal anxiety is improved when a parturient gets her choice with regard to the presence of a companion during epidural catheter placement for labor analgesia. It will be focused on parturients having their first child with the current partner. Additionally, it will investigate the effect of ethnicity, health literacy (as evaluated by the Newest Vital Sign questionnaire), catastrophizing (as evaluated by the Pain Catastrophizing Scale), and the relationship of the support person to the parturient. The investigators hypothesize that there may be specific subgroups in which maternal anxiety is improved when a parturient gets her choice regarding the presence of a companion during labor epidural catheter placement; however, a significant improvement in maternal anxiety, when including all participants, will not be appreciated.

COMPLETED
Comparison of PIEB vs CEI for Labor Analgesia
Description

The aim of this prospective, doubled-blinded randomized study is to compare two modes of epidural analgesia delivery, programmed intermittent epidural boluses (PIEB) versus continuous epidural infusion (CEI) with patient controlled epidural analgesia (PCEA) dosing, for providing labor epidural analgesia. The primary outcome will be the volume of local anesthetic received through PCEA. Secondary outcomes will measure time to first PCEA bolus, labor pain scores, degree of motor blockade, mode of delivery, PCEA attempts and ratio of successful to unsuccessful attempts, frequency of hypotension, duration of first and second stages of labor and level of patient satisfaction. The investigator plans to enroll 120 nulliparous participants at 2-5 com cervical dilation, with 60 patients to each arm. The subject will be assigned to receive either delivery of epidural medication ropivacaine 0.1% with fentanyl 2mcg/mL with PIEB + PCEA dosing method or CEI + PCEA. Continuous data will be analyzed using the Kruskal-Wallis test or t-test as appropriate. Categorical data will be analyzed using Chi-square test or Fisher's exact test as appropriate.

Conditions
TERMINATED
Does Ultrasound Help Junior Anesthesia Residents With Placement of Labor Analgesia in Pregnant Patients
Description

The investigators believe that ultrasound guided CSE technique will help junior resident rotating for the first time on the labor and delivery floor to place more accurately the epidural needle in the midline position as compared to placing the epidural needle via palpation of anatomical landmarks. This will result in increased ability to place the spinal component with positive cerebral spinal fluid (CSF) in the spinal needle, correct midline placement of the epidural catheter, and increase the likelihood of adequate symmetrical labor analgesia/anesthesia.

Conditions
TERMINATED
PIEB vs CEI for Labor Analgesia: An MLAC Study
Description

Utilizing a 'minimal local analgesic concentration (MLAC) study' design to first determine the relative potency of Programmed Intermittent Epidural Bolus (PIEB) compared to Continuous Epidural Infusion (CEI) and secondly to determine the mechanism to explain the potential PIEB efficacy advantage.

Conditions
COMPLETED
Patient Education on Labor Analgesia Options
Description

The purpose of this study is to learn how the investigators can better educate pregnant patients about the options open to them for pain relief during labor. Patients will receive educational pamphlet during prenatal clinic visit and again on admission to labor and delivery. The options for analgesia will be discussed by anesthesia care provider. Patient will be asked to complete a survey on the post partum unit.

Conditions
COMPLETED
Impact of Dural Puncture Epidural Versus Traditional Lumbar Epidural on Onset of Labor Analgesia
Description

This study is to examine the onset of pain relief with two different methods of labor epidural. The traditional labor epidural involves the placement of numbing and anti-pain medicine in the epidural space which surrounds the spinal cord. In order to take effect, the medication has to cross a layer of tissue called the dura. In the current study, the same medications are placed in the epidural space after the dura is punctured with a fine needle. This research, will help evaluate whether this technique will result in earlier onset of pain relief.

COMPLETED
Association Between Bolus Rate and the Adequacy of Labor Analgesia Using Timed-intermittent Boluses
Description

Administration of anesthetic solution into the epidural space is usually accomplished by a combination of continuous infusion, provider-administered boluses and patient-administered boluses (patient controlled epidural analgesia \[PCEA\]). The optimal method for maintaining labor analgesia is unknown. Several studies have demonstrated that timed-intermittent boluses, in combination with patient-controlled epidural analgesia (PCEA), provide superior maintenance of labor analgesia than maintenance with a continuous infusion with PCEA. Epidural infusion pumps capable of delivering timed boluses of local anesthetic with PCEA recently became commercially available. Several infusion rates are available for delivering the timed bolus, and the optimal bolus rate is unknown.

COMPLETED
Does Maternal Fever During Labor Analgesia Has Any Relationship With Maternal Ventilation?
Description

Epidural techniques offer the advantage of being able to titrate the level, density, and duration of the blockade through the use of a catheter and are associated with relative maternal hemodynamic stability. One of the disadvantages, however, include a raise in maternal temperature that is attributed to labor epidural technique. This study will assess if decreased maternal ventilation following induction of labor analgesia causes a raise in temperature.

Conditions
TERMINATED
Intrathecal Hydromorphone for Labor Analgesia
Description

The objective of this study is to evaluate the effect of intrathecal hydromorphone on the duration of labor analgesia and the incidence of epidural-associated temperature increase in laboring parturients. We hypothesize that intrathecal administration of longer-acting hydromorphone will: 1. Prolong the duration and improve the quality of analgesia in labor, and 2. Decrease the incidence of epidural-associated temperature increase in labor.

Conditions
COMPLETED
Does Ultrasound Help With Placement of Labor Analgesia in Pregnant Patients?
Description

The investigators believe that ultrasound guided CSE technique will accurately place the epidural needle in the midline position compared to epidural needle placement via palpation of anatomical landmarks. This will result in positive CSF in the spinal needle, correct placement of the catheter, and adequate symmetrical labor analgesia/anesthesia.

Conditions
TERMINATED
Inhaled Nitrous Oxide and Labor Analgesia
Description

Hypothesis: The administration of nitrous oxide for labor analgesia will decrease the labor epidural anesthesia rate by 15%. Specific Aim: To determine if nitrous oxide can be an effective alternative technique for the provision of labor analgesia at Magee-Womens Hospital.

Conditions
COMPLETED
Intrathecal Hydromorphone for Labor Analgesia
Description

This study will investigate the dose of hydromorphone which will relieve the pain of women in labor when delivered directly in the area around the spinal cord (i.e., intrathecal injection). The primary objective is to determine the dose of intrathecal hydromorphone that results in a pain score of less than 4 out of 10 thirty minutes after intrathecal injection in 50% of women. Secondary objectives include determining this dose at five and ten minutes after injection. Thirty women admitted to labor and delivery for planned vaginal delivery desiring epidural placement will be consented for the study. The starting dose of intrathecal hydromorphone will be 6 mcg. The up-and-down sequential allocation method of statistical analysis will be used, meaning that each subsequent dose will be dependent upon the result obtained from the prior dose - ergo, if the initial subject has pain relief, the second subject will receive 4 mcg (2 mcg less), but if the initial subject does not have pain relief, the second subject will receive 8 mcg (2 mcg more) of hydromorphone. After the intrathecal injection is given and the epidural is placed, visual analogue pain scores will be assessed 60 minutes following injection. A pain score of less than three will be a positive result. A pain score of three or greater will be a negative result. Blood pressure, heart rate, arterial oxygen saturation, fetal heart rate, and any side effects will also be assessed.

Conditions
COMPLETED
The Association Between Decreasing Labor Analgesia Epidural Infusion and Forceps Delivery
Description

The objective of this study will be to compare epidural infusion management, specifically looking at infusion rate changes, in patients who receive forceps deliveries versus normal spontaneous vaginal deliveries. We will match patients based on time and date of delivery, as well as parity, in order to eliminate these variables as potential con-founders. We hypothesize patients who require a decrease in their basal labor analgesia epidural infusion rate will have an increased incidence of forceps delivery.

NOT_YET_RECRUITING
The Impact of Needle Manipulation and Accuracy Between Hand Held Automatic and Traditional Ultrasound Device
Description

In this double blinded randomized controlled trial, the investigators would like to compare the effects on needle manipulation when relatively inexperienced sonographist (\< 1 year of ultrasound experience) perform ultrasound guided labor epidurals utilizing a traditional handheld ultrasound versus a handheld device that was engineered to provide automated guidance. The primary outcome of this study would be number of needle passes.

Conditions
WITHDRAWN
Epidural Loading Prior to Catheter Insertion
Description

This study explores the potential for a more rapid onset of pain relief when drug administration is performed through the epidural needle, a technique of epidural loading that provides a rapid and reliable level of labor analgesia without the disadvantages of a combined spinal-epidural, and could add a valuable new tool to anesthesiologists.

COMPLETED
Comparison of Epidural Labor Pain Relief Techniques on Maternal and Fetal Outcomes
Description

The primary objective of this study is to compare the onset and duration of the initial dose of medications given through three different epidural (conventional epidural, combined spinal epidural and dural puncture epidural) techniques for labor pain relief. The secondary objective of this study is to compare the fetal effects of these three epidural labor analgesia techniques.

RECRUITING
Impact of Prophylactic Ephedrine on Fetal Heart Tracing and Uterine Tetanic Contraction After CSE
Description

Labor analgesia is an important component of the care of laboring patients. A known side effect of combined spinal and epidural anesthesia (a type of labor analgesia) is an increased incidence of category II fetal heart rate tracing (defined below) and low blood pressure. The study team aims to study if a prophylactic dose of ephedrine will decrease the occurrence of this type of tracing after combined spinal epidural (CSE) anesthesia placement. Ephedrine is not currently routinely used as prevention for category II tracings or low blood pressure. The use of Ephedrine in this study is investigational (this is the first time that the drug has been studied for its effect on these conditions). Fetal heart rate (FHR) tracings are classified into three categories. In clinical practice, FHR tracing categories are used as a guide to obstetric management and suggest the following approach: * Category I tracing is "reactive" and reassuring → may continue labor * Category II tracing is neither category I nor category III. For obvious reasons, category II is the broadest and largest category, consisting of various FHR tracing patterns that do not fit into either category I or category III. * Category III tracing is non-reassuring → expedited vaginal or cesarean delivery recommended. A Category II tracing is not diagnostic. Most pregnancies have at least one Category II tracing. There is not always an identifiable reason for a Category II tracing. Ephedrine is a medication that causes an increase in heart rate and blood pressure while also causing some degree of relaxation of the uterus therefore improving uterine blood flow. It has been used in the obstetric population for over 50 years without issues. The dose that the research team will administer, 7.5 mg, is below the dose the research team will often administer to treat hypotension (low blood pressure).

Conditions
COMPLETED
Effectiveness of Clonidine, Dexmedetomidine, and Fentanyl Adjuncts for Labor Epidural Analgesia
Description

The purpose of this randomized controlled trial is to compare the effectiveness of epidural clonidine, dexmedetomidine, or fentanyl adjuncts for labor analgesia.

COMPLETED
Optimal Bupivacaine Dose for Initiation of Labor Epidural Techniques
Description

To estimate the dose of bupivacaine required to achieve initial effective comfort in 90% of patients (ED90) via the epidural (DPE or EPL) technique in women undergoing labor.

TERMINATED
3D Ultrasound-guided Labor Epidural Analgesia in the Morbid Obese Parturient
Description

This study will be a randomized control study, with the objective to evaluate epidural analgesia success rates between the two methods (Blind Approach versus Accuro Device).

COMPLETED
CSE v. Epidural for Postpartum Depression
Description

The purpose of this pilot prospective randomized control trial is to compare the initiation of labor epidural analgesia by combined spinal epidural vs. epidural for the influence on risk for postpartum depression symptoms. Investigators will randomize women to the receipt of CSE or E during labor, after measuring baseline psychological, psychosocial, and psychophysical factors related to pain and depression. The immediate research goals are to understand whether the association between labor pain and PPD is modifiable through the use of tailored anesthetic techniques.

TERMINATED
The Optimal Dosage of Intrathecal Morphine for Peripartum Analgesia
Description

The purpose of this study is to determine the ideal dosage of intrathecal morphine for intra and post partum analgesia, while minimizing the side effect profile.

Conditions
COMPLETED
The Effect of Neuraxial Analgesia on Maternal Breastfeeding
Description

A previous randomized trial showed a possible negative association with labor neuraxial analgesia with high compared to low doses of fentanyl, and breastfeeding at 6 weeks postpartum. The significance of this study would be to validate or refute these findings. In addition, we hope to better evaluate the impact of cumulative dose of fentanyl on breastfeeding success in the initial postpartum period as well as at 6 weeks and 6 months post delivery. In order to better assess the quality of breastfeeding, we will utilize a validated breastfeeding assessment tool, LATCH (Latch, Audible swallowing, Type of Nipple, Comfort, and Help). This validated tool can assess maternal and infant variables, define areas of needed intervention, and determine priorities in providing patient teaching. The LATCH assessment has been shown to be a predictor of breastfeeding duration. We also plan to vary the dosage of fentanyl analgesia to determine the relationship between doses below 150 micrograms and changes in breastfeeding assessments. If a clear association between decreased breastfeeding and total fentanyl is identified, then regimens to reduce cumulative doses of fentanyl can be developed to improve the likelihood of breastfeeding success in mothers that desire to breastfeed. Prior observational studies have inferred epidurals negatively affect breastfeeding by decreasing maternal plasma oxytocin release which may adversely affect infant neurobehavioral development. In a study by Beilin et al., it was reported that mothers receiving a high cumulative dose (\> 150 microgram) epidural fentanyl were more likely to have stopped nursing 6 weeks postpartum compared with groups receiving no fentanyl or those receiving \< 150 microgram. The study however, was underpowered to detect differences in breastfeeding prior to hospital discharge. In addition, the breastfeeding assessment tool utilized resulted in binary assessments, and therefore, a global rating of the quality of breastfeeding was not available.