38 Clinical Trials for Various Conditions
The FASTER stabilizing rod offers the distinct advantage of intubating through the laryngeal mask airway with a fiberoptic scope via the FASTER stabilizing rod. The device allows for the provider to insert the endotracheal tube (ETT) with visual confirmation using the fiberoptic scope into the trachea. The device then allows for the laryngeal mask airway to be removed while stabilizing the ETT to ensure the ETT does not get dislodged. The purpose of this protocol is to clinically test the validated prototype that the investigators have built and previously tested in adults with obesity. The primary aims are to evaluate 1) the time to intubation and 2) the number of intubation attempts. The secondary aim is to note any complications from time to intubation to PACU discharge. These complications include: Hypoxemia (10% decrease from baseline for 45 seconds)1 Airway trauma (minor) Esophageal intubation Laryngospasm Bronchospasm Oro-pharyngeal bleeding Arrythmia Emesis Epistaxis Dental damage Post-operative sore throat Post-operative hoarseness Accidental extubation during removal of the LMA.
The goal of this clinical trial is to compare the overall performance and patient outcomes of two video-assisted laryngeal mask airways (VLMAs) devices called Safe and Comfortable (SaCo) VLM and SafeLM® (Safe VLM) versus video laryngoscopy for airway management in adult patients, without an anticipated difficult airway, that are undergoing elective general anesthesia procedures. The main question it aims to answer is: Can both VLMAs improve patient-centered outcomes in the perioperative and postoperative periods in comparison to endotracheal tube (ETT) intubation? Thirty participants will undergo randomized VLMA with either the Safe VLM (15 participants) or the SaCo VLM (15 participants). And 15 participants will be intubated with ETT using video laryngoscopy, as the control group. Researchers will evaluate the efficacy of these two video-assisted devices in adult patients without an anticipated difficult airway in elective general anesthesia procedures. Other patient outcomes and exploratory endpoints will be recorded as well.
This prospective randomized study will evaluate the effectiveness of laryngeal mask airway (LMA) versus endotracheal intubation (ETT) for patients undergoing laparoscopic inguinal hernia at CMH.
This trial determines the feasibility of Laryngeal Mask Airway Gastro (Laryngeal Mask Airway) when used on patients who are undergoing endoscopic retrograde cholangiopancreatography for pancreas and bile duct disorders. Laryngeal Mask Airway is a device that helps patients breathe while they are asleep during procedures.
A prospective study designed to access changes in the intracuff pressure of a laryngeal mask airway (LMA) or cuffed endotracheal tube (cETT) during placement of an esophagogastroduodenoscopy (EGD) probe during an EGD in the pediatric population.
The investigators plan to conduct a randomized trial comparing the efficacy of intubating the tracheal using an Aintree intubation catheter through either the LMA-S or I-gel supraglottic devices
Laryngeal mask airways (LMA) have been shown to be a safe mode of airway management when delivering general anesthesia to patients during a variety of operative procedures. LMA's have been studied in a wide range of otolaryngologic procedures, and are generally safe and accepted by both anesthesia providers and surgeons alike. This study will aim to demonstrate the safety and efficacy of LMA for airway management during sinonasal surgery by directly comparing them to endotracheal intubation in a prospective randomized single-blind study.
In this study, newborn babies with respiratory distress syndrome (RDS), receiving oxygen via nasal continuous airway pressure (CPAP) modalities, and needing surfactant treatment will be randomized to standard delivery of surfactant via and endotracheal tube airway (inserted after pre-medication for pain with a short-acting narcotic), or to surfactant delivery via laryngeal mask airway (LMA). The intent is to remove the airways and return babies to non-invasive CPAP support, after surfactant is given. The primary outcome measure is the rate of failure of initial surfactant therapy. Standardized failure criteria are reached: a) early, if the baby is unable to be placed back on non-invasive CPAP (i.e., needs tracheal intubation and mechanical ventilation) or, b) late, if the baby requires ventilation, retreatment with surfactant within 8 hours or more than 2 doses of surfactant. The objective of this protocol is to reduce the need for endotracheal intubation and mechanical ventilation in preterm neonates with RDS needing rescue surfactant therapy by instilling surfactant though an LMA, while achieving comparable efficacy of surfactant treatment. The hypothesis is that surfactant treatment through an LMA will decrease the proportion of babies with RDS who require mechanical ventilation or subsequent intubation, when compared to standard surfactant treatment following endotracheal intubation with sedation.
Esophagogastroduodenoscopy (EGD) is a relatively common procedure in pediatric patients undergoing evaluation for various gastrointestinal ailments. The procedure itself, with or without associated biopsies, is relatively short in length. Unlike adults, who regularly undergo this procedure with conscious sedation, children most often require general anesthesia. While safe and effective, endotracheal tracheal tube (ETT) intubation of children for EGD can result in delayed awakening and slow room turnover, particularly when intravenous medications are required for intubation. Laryngeal mask airway (LMA) is an alternative to intubation, which permits removal before full awakening. Although considered a safe alternative to tracheal intubation in appropriate cases, disadvantages of the LMA have been reported including kinking, occluding view of the surgical field, failure of placement requiring tracheal intubation, aspiration of gastric contents, desaturation, and laryngospasm. The study was designed to determine whether use of an LMA for EGD could reduce operating room time, while providing satisfactory conditions for the endoscopist, and an equivalent side effect and safety profile as compared to ETT in otherwise healthy children with gastrointestinal complaints
A laryngeal mask airway ("LMA") is an airway device that is commonly used and placed under general anesthesia to facilitate ventilation of the patient's lungs while anesthetized. It is similar to an "endotracheal tube" (a breathing tube) but is less invasive. It is also placed as a backup when the Anesthesiologist is unable to pass a breathing tube and the patient is not adequately ventilating. Unfortunately, an LMA may lead to complications similar to those of breathing tube placement, such as sore throat and hoarse voice. Previous studies have examined several variables that may affect how often complications occur; these variables include giving anti-inflammatory medications and inflating the LMA to different pressures (the "working" end of the LMA, which rests in the patient's throat, has a cuff that is inflated to provide a seal). We are studying the effect of the PLACEMENT TECHNIQUE on postoperative sore throat, hoarse voice, and difficulty swallowing. We will be using 3 placement techniques - the traditional placement technique, a slightly different traditional placement technique, and a new technique, abbreviated the "ELLIA" method. The hypothesis of this study is that a new LMA insertion technique will have no difference in postoperative pharyngolaryngeal morbidity including sore throat, dysphagia and dysphonia.
The study will compare how often the tubing kinks when a LMA (laryngeal mask airway) with modified retractor is used compared to use of an endotracheal tube (ETT) and non modified retractor is used.
The aim of this randomized prospective study is to compare two single-use laryngeal mask airways the LMA Unique and the LMA Supreme, in pediatric patients. The investigators hypothesize that airway leak pressures with the LMA Supreme will be superior to the LMA Unique.
The aim of this randomized prospective study is to compare two single-use laryngeal mask airways with a provision of a gastric drain tube allowing for evacuation of gastric contents, the i-gel and the LMA Supreme, in pediatric patients undergoing positive pressure ventilation. The investigators hypothesize that airway leak pressures with the i-gel will not be significantly different clinically (higher) when compared with the LMA Supreme.
The aim of this randomized prospective study is to compare two laryngeal mask airways with a provision for evacuation of gastric contents, the LMA Proseal and The investigators hypothesize that airway leak pressures with the LMA Proseal will be significantly different (higher) when compared with the LMA Supreme.
The purpose of this research is to evaluate the effectiveness of fentanyl for reducing coughing during the perioperative period (i.e., insertion of an LMA \[Laryngeal Mask Airway\] device, maintenance period during surgery, and awakening \[emergence\] from general anesthesia) for ambulatory surgery procedures. Also to assess the effects of fentanyl on the postoperative outcomes, (e.g., pain, postoperative nausea and vomiting, return of bowel function \[constipation\], resumption of normal activities of daily living). Fentanyl is one of the most common used anesthetic adjuncts for ambulatory surgery because of its anesthetic-sparing effects and alleged ability to reduce coughing during instrumentation of the patient's airway.
Introduction: The air-QⓇ Intubating Laryngeal Airway (ILA) is a newer supraglottic airway. It is approved for use as a primary airway and as an aid for intubation in situations of anticipated or unanticipated difficult airways. A unique feature of this device as compared to other airways on the market is the size of the inner diameter (ID) and length of its airway tube. Direct placement of tracheal tubes \> 7.5 mm ID through the airway tube is possible. The ProSealTM LMA is considered the gold standard for supraglottic devices with respect to airway seal pressure. On average, it is reported to be approximately 28 cmH2O. This is significantly higher than that of the first generation LMA, the LMA-ClassicTM, which has a maximum seal pressure of 20 cmH2O, but averages 16-18 cmH2O in actual practice. In this study the investigators aim to test whether the air-QⓇ creates an airway seal pressure that is similar to the LMA-ProSealTM, whether the position of the air-QⓇ in relation to the vocal cords, as assessed by fiberoptic endoscopy, is similar to that of the LMA-ProSealTM and whether airway morbidity is similar between the air-QⓇ and the LMA-ProSealTM.
The air-Q® intubating laryngeal airway (ILA) is an supraglottic device used for both airway maintenance during routine anesthesia and as a conduit for tracheal intubation for patients with a difficult airway. The investigators goal for this study is to compare the performance of the ILA with the current standard of care the standard LMA during routine anesthesia.
The investigators plan to test the hypothesis that pretreatment with fentanyl prior to induction of anesthesia would result in reduce the incidence of movements and airway responses to desflurane in patients breathing spontaneously through a laryngeal mask airway (LMA). The primary aim of this study is to assess the effect of fentanyl pretreatment on the incidence of movement during induction of anesthesia. Secondary aim of the study is to evaluate the effects of titration of fentanyl according to the respiratory rate on the incidence of intraoperative respiratory events such as coughing, breath holding and laryngospasm.
The aim of the current study is to compare the use of laryngeal mask airway (LMA) and endotracheal tube (ETT) in pediatric adenotonsillectomy. The primary objective is to assess the incidence of post-operative laryngospasm between the LMA and ETT. The investigators also sought to compare anesthetic, operative, and recovery times in the LMA and ETT groups. We hypothesized that the LMA would be a safe efficient alternative to the ETT.
The primary objective of this research is to compare the need for intubation and mechanical ventilation in the first seven days of life for infants with respiratory distress syndrome (RDS) on nasal continuous positive airway pressure (nCPAP) who receive surfactant via a Laryngeal Mask Airway (LMA) with those who are maintained on nCPAP and do not receive surfactant.
In this study, newborn babies with respiratory distress syndrome (RDS), receiving oxygen via nasal CPAP, and needing surfactant treatment will be randomized to standard delivery of surfactant via and endotracheal tube airway(inserted after pre-medication for pain), or to surfactant delivery via laryngeal mask airway (LMA). The intent is to remove the airways and return babies to nasal CPAP, after surfactant is given. The primary outcome measure is the rate of failure of initial surfactant therapy. Standardized failure criteria are reached: a) early, if the baby is unable to be placed back on CPAP (needs mechanical ventilation) or, b) late, if the baby requires retreatment with surfactant within 8 hours or more than 2 doses of surfactant. The objective of this protocol is to reduce the need for endotracheal intubation and mechanical ventilation in preterm neonates with RDS needing rescue surfactant therapy by instilling surfactant though an LMA, while achieving comparable efficacy of surfactant treatment. The hypothesis is that surfactant treatment through an LMA will decrease the proportion of babies with RDS who require mechanical ventilation or subsequent intubation, when compared with standard surfactant treatment following sedation and endotracheal intubation.
Laryngeal mask airway (LMA) is routinely used for some patients who have surgery under general anesthesia. LMA is placed in the mouth and allow the anesthesia to be given without having to put a breathing tube in the throat. Previous studies have focused on the effect of different anesthesia medicines on optimal condition for LMA use. The objective of the present study is to find the optimal time for LMA insertion.
The purpose of this research study is to compare difference between breathing by oneself or with the partial help from an anesthesia machine in children under general anesthesia.
Laryngeal mask airway is a widely used device in routine anesthesia for airway management during surgery. It consists of a tube with an inflatable cuff that is inserted into the mouth after induction of general anesthesia. The Proseal Laryngeal mask airway and the Laryngeal mask airway Supreme are two variants of the Laryngeal mask airway. The laryngeal mask airway Supreme is a newer version of the laryngeal mask airway. The research is being done to compare two variants of the laryngeal mask airway: the Proseal laryngeal mask airway and the Laryngeal mask airway Supreme. This study will determine if the newer model, the Laryngeal mask airway Supreme, is easier to insert and is better positioned than the older model, the Proseal laryngeal mask airway. Both models are approved for use by the FDA, and are routinely used to assure the airway during general anesthesia.
The purpose of this study is to determine the effectiveness of the Fastrach and the CTrach Laryngeal mask airway to achieve placement of a breathing tube in the windpipe of patients where this may be difficult.
The purpose of this study is to evaluate a new disposable supra-glottic airway device, the i-gel airway (Intersurgical Ltd., Wokingham, England). We propose to test its ease of insertion, position within the airway, drain tube patency and anatomic sealing properties during mechanical ventilation in non-obese anesthetized patients undergoing elective general surgery. The study device will be compared to the current standard in the industry, the LMA Unique.
In this protocol we will conduct a randomized controlled trial where babies with respiratory distress syndrome (RDS) who have not yet reached criteria for intubation, will be randomized to receive surfactant by LMA or to continue receiving standard therapy of nasal CPAP and supplemental oxygen. All babies will be given surfactant by endotracheal tube if they reach "failure" criteria, which is the standard criterion for surfactant administration (i.e., FiO2= 65% while receiving nasal CPAP). The objective of this RCT is to determine if surfactant can be successfully administered by LMA, thus perhaps avoiding the need for endotracheal intubation. The hypothesis is that fewer babies in the LMA group would reach failure criteria.
The purpose of this study is to determine if the Ambu Laryngeal Mask can be used as an intubation conduit for endotracheal intubation.
The air-Q Self-Pressurizing Intubating Laryngeal Airway (aILA SP) is a modification of the air-Q Intubating Laryngeal Airway (aILA). Besides the i-gel, it is the only breathing tube that sits above the vocal cords that does not require inflation of a cuff with air. The purpose of this study is to compare the ability of the aILA-SP to maintain patency of a patient's airway during general anesthesia with that of the aILA and i-gel devices. As a measure of this ability, we hypothesized that the airway sealing pressures will be equal between the aILA-SP and aILA, but superior when comparing the aILA-SP to the i-gel (i-gel will be lower).
This prospective, randomized, comparative study is intended to enroll a total of 148 patients with a BMI 30-49.9 kg/m2 undergoing surgery at Parkland Hospital. The efficacy and performance of a second-generation LMA will be compared to endotracheal intubation. A standardized anesthetic protocol that is usual and customary for the type of operation the patient is having will be provided to the anesthesia teams of enrolled subjects. The remainder of the anesthetic care of the subject will not deviate from the standard of care.