Treatment Trials

178 Clinical Trials for Various Conditions

Focus your search

TERMINATED
Catheter Ablation vs. Medical Therapy in Congested Hearts With AF
Description

This study is a multi-center, randomized, unblinded, clinical trial. The objective is to determine if catheter-based atrial fibrillation (AF) ablation is superior to medical treatment in patients with impaired left ventricular (LV) function who have been diagnosed with symptomatic AF within the past 12 months.

COMPLETED
Evaluation of the Effects of Carperitide in Patients With Congestive Heart Failure
Description

The study will evaluate the safety and efficacy of intravenous infusion of carperitide using pressure measurements inside the heart and great vessels and measuring carperitide concentration in the blood.

TERMINATED
Reversible Pulmonary Artery Banding as Simplified Management of End-stage Dilated Left Ventriculopathy in Early Life
Description

The purpose of this study is to: 1) Remodel and restore left ventricular geometry and function. 2) Avoid the need for mechanical circulatory support (MCS) and/or cardiac transplantation (CT). 3) Confirm the outcomes of a pilot study completed in Germany and reported in The Journal of Heart and Lung Transplantation in May 2013.

COMPLETED
The Effects of Nitric Oxide for Inhalation During Left Ventricular Assists Device (LVAD) Implantation
Description

The purpose of this study is to assess the utility of nitric oxide for inhalation during left ventricular assist device (LVAD) implantation following cardiopulmonary bypass (CPB). This is to be assessed by the number of patients in each treatment group meeting failure criteria within 24 hours on study drug, as defined by two or more of the following: * Left ventricular flow rate index (LVFRI) ≤ 2.0 L/min/m\^2 * Administration of ≥ 20 inotropic equivalents (IE) * 10 µg/kg/min dopamine, dobutamine, enoximone or amrinone is equivalent to 10 IE * 0.1 µg/kg/min epinephrine or norepinephrine is equivalent to 10 IE * 1 µg/kg/min milrinone is equivalent to 15 IE * 0.1 U/min vasopressin is equivalent to 10 IE * Mean arterial pressure (MAP) ≤ 55 mmHg * Central venous pressure (CVP) ≥ 16 mmHg * Percent mixed venous oxygen saturation (SvO2) ≤ 55% Or at least one of the following criteria: * Failure to wean from cardiopulmonary bypass at least once due to hemodynamic failure. Re-initiation of cardiopulmonary bypass to correct bleeding or other technical issues will not be considere 'failure to wean' * Death

RECRUITING
Investigation of the BrioVAD System for the Treatment of Left Ventricular Heart Failure
Description

The goal of this study is to evaluate the safety and efficacy of the BrioVAD System by demonstrating non-inferiority to the HeartMate 3 Left Ventricular Assist System when used for the treatment of advanced, refractory, left ventricular heart failure.

COMPLETED
Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical SWIFT HM3 PMS
Description

This is a prospective, post-market, multi-center, non-blinded, single arm study of the HeartMate 3 Left Ventricular Assist System (LVAS). The objective of this study is to evaluate the implantation of the HM3 utilizing techniques other than full median sternotomy (e.g. thoracotomy) and impact on post-implant length of stay.

COMPLETED
MOMENTUM 3 Pivotal Cohort Extended Follow-up PAS
Description

The study will be a prospective, multi-center, non-blinded, controlled study, intended to evaluate the extended use of the HM3 LVAS compared to the HMII LVAS in those patients that are ongoing at the 2-year follow-up in the MOMENTUM 3 IDE trial. A total of 1028 subjects were enrolled in the MOMENTUM 3 IDE trial. Approximately 533 subjects were ongoing support at the 2-year follow-up and are eligible for enrollment in this PAS. This study will be conducted at sites that participated in the MOMENTUM 3 IDE trial which will include up to 69 centers in the United States.

COMPLETED
MOMENTUM 3 Continued Access Protocol
Description

The objective of the study is to continue to evaluate safety and clinical performance of the HM3 LVAS for the treatment of advanced, refractory, left ventricular heart failure following completion of enrollment in the the MOMENTUM 3 IDE Study.

COMPLETED
MOMENTUM 3 IDE Clinical Study Protocol
Description

The objective of the study is to evaluate the safety and effectiveness of the HM3 LVAS by demonstrating non-inferiority to the HMII LVAS (HMII) when used for the treatment of advanced, refractory, left ventricular heart failure.

COMPLETED
Attain StarFix™ Model 4195 Left Ventricular Lead
Description

People who have abnormal heart beats, or whose heart does not beat on its own, may need an electronic device called a pacemaker or a defibrillator. Furthermore, people whose hearts have a reduced pumping ability may need a device are called cardiac resynchronization therapy (CRT) device. A CRT device is implanted surgically just under the skin in the upper chest area. This device then helps the heart beat at a regular rhythm by sending electrical signals (pacing) directly to the heart tissue through flexible wires called leads. The device may also be able to stop the heart from beating too fast. Three leads are implanted into the chambers of your heart. Two of the leads will be placed on the right side of your heart. The third lead is placed on the left side of your heart and is the lead being studied. The purpose of this study is to evaluate the safety and efficacy of the Attain StarFixTM Model 4195 Left Ventricular (LV) Lead. This particular model lead has special characteristics that may help to better keep it in position once it is implanted into the left ventricle. It is also "steroid-eluting" which means that over time it slowly releases a small amount of medication into the heart tissue to help prevent too much swelling around the area it is implanted.

Conditions
COMPLETED
Study to Evaluate the Efficacy and Safety of AZD4831 in Participants With Heart Failure With Left Ventricular Ejection Fraction > 40%
Description

This is a randomised, double-blind, placebo-controlled, multi-center sequential phase 2b and Phase 3 study to evaluate the efficacy and safety of AZD4831 administered for up to 48 Weeks in participants with heart failure with left ventricular ejection fraction \> 40%. The study will consist of 2 separate parts, Part A and Part B, approximately 660 participants will be randomised in Part A, 820 in Part B.

COMPLETED
Study to Evaluate the Efficacy (Effect on Disease) and Safety of Finerenone on Morbidity (Events Indicating Disease Worsening) & Mortality (Death Rate) in Participants With Heart Failure and Left Ventricular Ejection Fraction (Proportion of Blood Expelled Per Heart Stroke) Greater or Equal to 40%
Description

The purpose of this study is to evaluate the effect of finerenone compared to placebo (a tablet without active substance) in the reduction of cardiovascular death (generally meaning death due to disease of the heart or blood vessels) and total Heart Failure (HF) events, including HF hospitalization and urgent visits for HF(generally meaning a hospital stay or urgent presentation to a healthcare unit due to worsening symptoms of heart failure) in patients suffering from HF with an ejection fraction greater than or equal to 40%. Researchers will also collect information on how much the heart disease has impact on patient's lives, change of kidney function, and how well finerenone treatment is tolerated. The study plans to enroll 6000 male and female patients of the age of 40 years and above suffering from heart failure with ejection fraction greater than or equal to 40%. Participants will take the study product as oral tablet with a dose between 0 (Placebo) 40 mg once daily. Study duration will be up to 43 months.

Conditions
COMPLETED
A Study of Ivabradine in African-American/ Black Subjects With Heart Failure and Left Ventricular Systolic Dysfunction.
Description

This study is a prospective, open-label, single-arm intervention study in African-American/Black subjects with heart failure and reduced ejection fraction (HFrEF). There will be a 7-day screening period, a 57-day open-label treatment period, and a safety follow-up at day 87 or 30 days after the last administration of the investigational product.

COMPLETED
Phase IIb Safety and Efficacy Study of Different Oral Doses of BAY94-8862 in Subjects With Worsening Chronic Heart Failure and Left Ventricular Systolic Dysfunction and Either Type 2 Diabetes Mellitus With or Without Chronic Kidney Disease or Chronic Kidney Disease Alone
Description

To assess a new drug, BAY94-8862, given orally at different doses, to evaluate whether it was safe and can help the well-being of patients with worsening chronic heart failure and either type II diabetes with or without chronic kidney disease or kidney disease alone. These treatment doses were compared to eplerenone, another marketed drug approved to treat heart failure.

Conditions
COMPLETED
Study of Left Ventricular Dyssynchrony in Heart Failure Patients
Description

Heart failure has become one of the major epidemics of the modern era. Despite optimal standard drug therapy, the prognosis of patients with heart failure remains poor. Patient with Heart Failure are prone to have "dyssynchrony" which means that there are electrical disturbances that cause the heart to pump blood in an inefficient way. Ventricular dyssynchrony has been associated with increased mortality in patients with heart failure. Based on these observations, techniques have been developed to correct dyssynchrony. The investigators propose to investigate the change of dyssynchrony in relation to intravascular volume status and exercise in heart failure patients. The investigators also propose to examine dyssynchrony in the setting of acutely decompensated heart failure. The change in dyssynchrony will be followed to examine if it translates into clinical significance.

Conditions
COMPLETED
Stem Cell Therapy in Patients With Severe Heart Failure & Undergoing Left Ventricular Assist Device Placement
Description

The purpose of this study is to determine if the delivery of cells just after implantation of left ventricular assist device will help to improve the pumping function of your heart and minimize heart enlargement in the future. The cells will be obtained by aspiration or withdrawal of fluid from your bone marrow from your pelvic bone using a needle and syringe. This would not take place until 24-48 hours prior to your planned left ventricular assist device implantation. During the surgery the surgeons will inject the prepared cells that were taken from your bone marrow and inject it into your heart muscle. This study will test whether receiving your own bone marrow cells directly into your heart will help your heart to recover function after placement of a left ventricular assist device.

Conditions
TERMINATED
Results of Tc99m-Maraciclatide Scintigraphy in Subjects With Diabetes Mellitus and Heart Failure With Preserved Left Ventricular Ejection Fraction
Description

The purpose of this study is to evaluate the results of 99mTc maraciclatide scintigraphy in diabetic subjects with HFPEF. A maximum of 20 subjects with Diabetes Mellitus (DM) and Heart Failure With Preserved Left Ventricular Ejection Fraction (HFPEF) will be enrolled and imaged with 99mTc maraciclatide. In addition, a maximum of 10 subjects with DM and diastolic dysfunction but no diagnosis of heart failure (HF) will be enrolled and imaged with 99mTc-maraciclatide.

RECRUITING
Vericiguat in Pediatric Participants With Heart Failure Due to Left Ventricular Systolic Dysfunction (MK-1242-043)
Description

The primary objective of this study is to monitor the safety and tolerability of vericiguat.

RECRUITING
Efficacy, Safety, and Pharmacokinetics of Vericiguat in Pediatric Participants With Heart Failure Due to Left Ventricular Systolic Dysfunction (MK-1242-036)
Description

This study aims to compare the efficacy of vericiguat versus placebo on change in n-terminal pro-brain natriuretic peptide (NTproBNP) from baseline to Week 16 of the Base Period. The primary hypothesis is that vericiguat is superior to placebo in reducing NT-proBNP at Week 16 of the Base Period.

SUSPENDED
SCD for CRS in Congestive Heart Failure (CHF) (No Left Ventricular Assist Device)
Description

The purpose of this clinical trial is to see if a new device (SCD) is safe and if it can reduce damage to the kidney enough to allow medications to work to improve heart and kidney function for use in patients that have moderate to severe heart failure and is at least in part due to heart failure and it not responding to standard medical therapy. The SCD is a cartridge used with a commercial hemodialysis unit. Participants will be enrolled in the clinical trial once eligibility is confirmed. In addition to clinical assessments and laboratory testing participants will have surface echocardiograms during the trial. The SCD treatment will take place for 4 hours on day 1, 3, and 5 while on hemodialysis.

COMPLETED
Single Ascending Doses of GGF2 in Patients With Left Ventricular Dysfunction and Symptomatic Heart Failure
Description

Study to determine the safety, tolerability, pharmacokinetics and immunogenicity of single intravenous administrations of GGF2 in patients with heart failure.

Conditions
COMPLETED
LCZ696 Compared to Valsartan in Patients With Chronic Heart Failure and Preserved Left-ventricular Ejection Fraction
Description

The study will assess the effects of 36 weeks of treatment with LCZ696 compared to valsartan on N-terminal pro-Brain Natriuretic Peptide (NT-proBNP) in patients with chronic heart failure and preserved left-ventricular ejection fraction.

COMPLETED
Multicenter, Randomized, Double-Blind, Placebo Controlled, Efficacy Study on the Effects of Tolvaptan on Left Ventricular Dilatation in Congestive Heart Failure Patients
Description

The purpose of this study is to study the effects of tolvaptan on the size and function of the left heart chamber (ventricle) in patients with congestive heart failure (CHF)

COMPLETED
Study on the Effects of Sacubitril/Valsartan on Physical Activity and Sleep in Heart Failure With Reduced Ejection Fraction Patients.
Description

The purpose of this study was to investigate the effects of initiation of sacubitril/valsartan vs enalapril treatment on objective measures of both waking activity and sleep in subjects with heart failure with reduced ejection fraction.

COMPLETED
Post Approval Registry of Corox OTW, Endocardial, Left Ventricular Steroid Lead, Bipolar
Description

The objective of this study is to confirm the long-term safety and reliability of the Corox OTW BP left ventricular (LV) pacing lead. As a condition of approval, the FDA required that a registry documenting the post approval clinical experience of these leads be designed and implemented.

COMPLETED
CRD-102 for Right Heart Failure in Patients With Left Ventricular Assist Devices
Description

This is a Phase 1b/IIa, single centre, non-randomised open-label uncontrolled study to assess safety, effect and PK of oral CRD-102 in patients with RHF associated with the presence of an LVAD.

COMPLETED
Interleukin-1 Receptor Antagonist for the Treatment of Heart Failure in Patients With Left Ventricular Assist Devices
Description

Heart failure remains a major cause of morbidity and mortality. Many patients with heart failure receive support from a left ventricular assist device (LVAD) at some point in the course of their disease. Some of these LVAD patients experience a durable recovery after ventricular unloading with an LVAD, which may be associated with inhibition of inflammatory cytokines. This small pilot study aims to determine the biologic and clinical efficacy of an interleukin-1 receptor antagonist (Anakinra) at inducing myocardial recovery in patients supported with left ventricular assist devices.

Conditions
TERMINATED
Correlating Noninvasive Cardiovascular Measures to Left Ventricular End Diastolic Pressure in Heart Failure
Description

HF001 is a prospective observational study utilizing non-invasive medical devices that may be able to discriminate changes in heart failure while acutely decompensated patients undergo routine interventional therapies in a hospital setting. Subjects will be monitored using CVInsight™ \[CVI\] via a finger and/or forehead sensor, while performing an isometric handgrip stress test (IHGST). Changes in the CVI signal will be analyzed and correlated to standard assessments of heart failure including pulmonary artery catheter (PAC) pressures, blood pressure (BP), patient symptoms, and physical exam findings. The results of this study will be used to develop a powered study to determine if a new configuration of non-invasive monitoring devices can be used to monitor heart failure status more sensitively than current non-invasive techniques.

Conditions
COMPLETED
Right Ventricular Failure After Implantation of Left Ventricular Assist Devices
Description

The left ventricular assist device (LVAD) is a portable mechanical pump that helps the left side of the heart of patients with severe heart failure that are awaiting heart transplantation or are not transplant candidates. However, while LVAD supports the left side of the heart, the right side must work on its own. Sometimes the right side does not recover, a condition called right ventricular failure (RVF). This complication increases mortality, prolongs hospitalization, requires additional procedures, and increases costs. Several risk factors and scores have been proposed to identify patients at risk for RVF. However, these methods have proven inadequate; one out of three patients is still experiencing right ventricular failure after LVAD surgery. Echocardiography, an established noninvasive method to see the heart without radiation or risk, has a lot of potential to identify patients at risk for RVF. The questions we will tray to answer with this American Heart Association funded project are: 1. Can echocardiography before scheduled LVAD surgery predict who is going to develop RVF and poor quality of life so we can better select patients for LVAD surgery? 2. Can echocardiography before scheduled LVAD surgery tell us the course of right ventricular function after implantation so we can potentially take additional measures and prevent RVF? To answer these questions, we will record images of the heart with echocardiography before LVAD surgery in 120 LVAD recipients at Emory University. We will then follow the patients for 90 days to detect any symptoms and signs of clinical RVF and poor quality of life and record the course of right ventricular function with echocardiography. Currently, it is estimated that 150,000 to 250,000 patients in US are potential LVAD recipients with 2,000 devices implanted in 2012. LVAD can improve survival and quality of life in suitable patients. However, implantation requires a major surgical procedure with associated risks and considerable resources. Thus, careful patient selection is necessary to minimize risk for patients and maximize benefit for patients and society. Our long-term goal is to use echocardiography as a tool to (1) optimally select patients for LVAD and offer alternatives to patients at increased risk for complications and (2) potentially, inform earlier LVAD implantation in patients with weakening right ventricular function.

Conditions
RECRUITING
Conduction System Vs Surgical Left Ventricular Epicardial Pacing For Coronary Sinus Lead Failure
Description

This a single-center, retrospective, observational study of patients that undergo coronary sinus(CS) lead revision, comparing epicardial lead placement to coronary sinus pacing(CSP) in those that had lead failure.