14 Clinical Trials for Various Conditions
The objective of this clinical study is to collect additional data on the safety and effectiveness of the EPi- Sense®-AF Guided Coagulation System with VisiTrax® to treat symptomatic persistent or long-standing persistent Atrial Fibrillation (AF) patients who are refractory or intolerant to at least one Class I and/or III AAD.
This is a prospective, single-arm trial. The objective of the study is to determine the rate of atrial arrhythmia recurrence after pulmonary vein isolation (PVI) plus posterior wall isolation (PWI) using the Farawave PFA catheter in patients with longstanding persistent atrial fibrillation (AF). The trial will be conducted at as many as 10 US sites. Upon completion of site initiation, enrollment is expected to accrue at a rate of 10 patients per month. Total enrollment is expected to consist of 100 subjects. Accrual is expected to take 18 months, and all patients will be followed for 12 months post randomization. This study will be completed in 2 phases. There will be a 20 subject pilot phase, enrolled at one site (Mount Sinai). After completion of the pilot phase, the FDA will be provided with acute safety data (1 month). During the FDA's review of the pilot phase, enrollment may continue at the initial site. Also, IRB submissions at other prospective sites (up to a total of 10) may be initiated. Upon receipt of the go-ahead from FDA and after consultation with the study sponsor, the second phase of the study (to enroll 100 total subjects) will be performed. This research study currently has approval to enroll 25 patents. Should FDA grant approval to continue the study, the research team will expand as above and update this posting.
The purpose of this study is to assess the safety and technical feasibility of treating subjects with Persistent Atrial Fibrillation or Longstanding Persistent Atrial Fibrillation in a minimally invasive thoracoscopic ablation procedure utilizing the AtriCure Bipolar System, with mapping and additional lesion creation/ gap closure (as needed) provided by currently approved catheter technology, when the epicardial and endocardial phases are performed in a staged manner within 1-10 days apart, during the same hospitalization.
This prospective study aims; 1. To assess if pre-ablation levels of inflammatory biomarkers serve as independent predictors of procedure outcome 2. To evaluate the inflammatory activation following catheter ablation by measuring serum-biomarker levels 24-hours after the procedure and examine the predictive role in procedure success 3. To determine if a change in the baseline level of certain inflammatory biomarkers at 3-months post-ablation period has any correlation with the long-term outcome in patients with atrial fibrillation 4. To study the association of certain biomarkers with specific types of AF (paroxysmal or persistent or long standing persistent)
The DISRUPT-AF Registry is an observational, prospective, multi-center, non-randomized, real-world registry designed to obtain clinical experience with the Farapulse Pulsed Field Ablation System for the treatment of atrial fibrillation (AF).
The primary objective of this study is to evaluate the safety and effectiveness of the AtriCure CryoICE system in performing the Cox-Maze III lesion set, in conjunction with Left Atrial Appendage (LAA) exclusion using the AtriClip device.
The purpose of this study it to learn whether pulmonary vein isolation (PVI) along with ablation of the posterior left atrial wall (PLAW) will reduce the likelihood of atrial fibrillation (AF) recurrence in patients with persistent or long-standing persistent AF one year after an ablation procedure in comparison to a PVI ablation procedure, alone. The investigator hypothesizes that the combination of PVI plus PLAW isolation will result in a reduction in recurrence of atrial arrhythmias at one year after ablation.
This prospective study aims to investigate if termination of atrial fibrillation (AF) after pulmonary vein antrum isolation (PVAI) without additional ablation of non-PV triggers, in long-standing persistent (LSP) AF, is enough to ensure long-term success.
This prospective randomized study aims to investigate the effect of continuous versus interrupted use of Amiodarone on the procedure outcome in long-standing persistent (LSP) atrial fibrillation patients undergoing pulmonary vein antral isolation (PVAI).
This is a prospective, observational, single center pilot trial to find out if a new computerized technology for analysis of the electrical activity recorded during atrial fibrillation can identify the electrical source of this arrhythmia. If we are able to reliably identify the source, then in the future we may be able to use this technology to determine the optimal sites for catheter ablation of atrial fibrillation in the heart. The present study will compare the standard electrical recordings to the new computerized algorithm analysis of recordings gathered at the same time. The study will enroll 30 participants with persistent or longstanding persistent atrial fibrillation (AF) that are scheduled for elective catheter ablation of AF. The catheters that are being placed in the heart are standard Food and Drug Administration (FDA)-approved mapping catheters. The investigational computerized software that will be employed in the trial will be used after the case has done and will not directly impact any of the activities during the ablation procedure. Information learned from this trial will improve understanding of the mechanisms of atrial fibrillation and will potentially improve success rates of AF ablation for patients in the future and will be used to design a prospective trial.
The purpose of this study is to demonstrate the safety and effectiveness of the Cardioblate iRF and CryoFlex hand held devices for the treatment of non-paroxysmal AF.
The purpose of this clinical investigation is to evaluate how safe a less invasive cardiac surgery is using the AtriCure Bipolar System combined with a catheter ablation procedure in treating AF, and how effective this combined procedure is using the AtriCure System in treating AF. The AtriCure Bipolar System will be used to perform the less invasive cardiac surgery and a standard electrophysiology catheter, currently available, will be used to perform the catheter ablation procedure. This surgical procedure is considered less invasive because it is done through tiny surgical punctures on the sides of the chest near the ribs instead of one large surgical incision of the breast bone to completely open the chest and access the heart, and it also avoids the need for the heart-lung bypass machine.
This is a multi-center, prospective open label, feasibility study evaluating the safety and efficacy of the combined ablation procedure for the treatment of longstanding persistent atrial fibrillation.
The primary objective of this post-approval study is to evaluate the clinical outcomes in a cohort of patients with non-paroxysmal forms of atrial fibrillation (persistent or long-standing persistent) treated during commercial use of the AtriCure Synergy Ablation System by physicians performed the Maze IV procedure.