Treatment Trials

24 Clinical Trials for Various Conditions

Focus your search

COMPLETED
NHLBI DIR LAMPOON Study: Intentional Laceration of the Anterior Mitral Leaflet to Prevent Left Ventricular Outflow Tract Obstruction During Transcatheter Mitral Valve Implantation
Description

Background: Transcatheter mitral valve replacement (TMVR) is recommended for some people with mitral valve heart problems. But the usual TMVR techniques might cause an obstruction for some people. A new technique is called LAMPOON. It may have less risk of obstruction. Participants in this study will be among the first in the world to have this technique done. Objectives: To test the safety and effectiveness of the LAMPOON technique in TMVR. Eligibility: Adults ages 21 and over who are recommended to have TMVR with LAMPOON Design: Participants will be screened with medical history and exam and by review of medical records. Participants will have blood tests, an ECG, a heart CT scan, and an echocardiogram before the procedure. Participants will have TMVR with LAMPOON. They will have anesthesia or moderate sedation for the procedure. Doctors will use a wire to split the diseased mitral valve and move it out of the way before inserting the artificial mitral valve. Participants will recover in an inpatient recovery unit. They will repeat the previous tests before leaving the hospital, 1 month later, 6 months later and 1 year later. They will have yearly follow-up phone calls for about 5 years. In the event of a participant's death, researchers will ask for an autopsy and to analyze the heart. Permission for this is not required as part of the study.

ACTIVE_NOT_RECRUITING
Early Feasibility Study for the Foldax TRIA Mitral Heart Valve Replacement
Description

The purpose of this study is to conduct the initial clinical investigation of the Foldax Polymer Mitral Valve to collect evidence on the device's safety and performance. The study is anticipated to confirm successful clinical safety and clinical effectiveness with significant improvements in clinical hemodynamic performance.

ACTIVE_NOT_RECRUITING
Caisson Transcatheter Mitral Valve Replacement (TMVR)
Description

The purpose of this study is to assess the safety and performance of Transcatheter Mitral Valve Replacement (TMVR) system for the treatment of severe, symptomatic mitral regurgitation (MR).

COMPLETED
Early Feasibility Study of the AccuCinch® Ventricular Restoration System in Patients With Prior Mitral Valve Intervention (PMVI) and Recurrent Mitral Regurgitation
Description

This is a non-randomized, prospective, multi-center Early Feasibility Study of the AccuCinch® Ventricular Restoration System in Patients with Prior Mitral Valve Intervention (PMVI) and Recurrent Mitral Regurgitation.

ACTIVE_NOT_RECRUITING
PARTNER 3 Trial - Mitral Valve in Valve
Description

To assess the safety and effectiveness of the SAPIEN 3 transcatheter heart valve in patients with a failing mitral bioprosthetic valve.

RECRUITING
The EMPOWER Trial - The Carillon Mitral Contour System® in Treating Heart Failure With at Least Mild FMR
Description

The objective of this prospective, randomized, blinded clinical trial is to assess the safety and efficacy of the Carillon Mitral Contour System in treating heart failure with functional regurgitation (FMR).

COMPLETED
The CorCinch - Functional Mitral Valve Regurgitation (FMR) Study
Description

This is a multi-center, non-randomized, prospective Early Feasibility Study to evaluate the AccuCinch® Ventricular Restoration System in patients with symptomatic heart failure and concomitant functional mitral regurgitation that have stable symptoms on guideline-directed medical therapy

UNKNOWN
Caisson Transcatheter Mitral Valve Replacement (TMVR) System Early Feasibility Study
Description

The purpose of this study is to assess the safety and performance of the Caisson Interventional Transcatheter MitralValve Replacement (TMVR) system for the treatment of severe symptomatic MitralValve Regurgitation (MR).

ACTIVE_NOT_RECRUITING
Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation (The COAPT Trial) and COAPT CAS
Description

The purpose of the Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation (COAPT) Trial is to confirm the safety and effectiveness of the MitraClip System for the treatment of moderate-to-severe or severe functional mitral regurgitation (FMR) in Symptomatic Heart Failure Subjects who are treated per standard of care and who have been determined by the site's local heart team as not appropriate for mitral valve surgery. This randomized controlled trial will provide the opportunity to strengthen or add labeling claims regarding safety and clinical benefits of the MitraClip System for symptomatic heart failure patients with moderate-to-severe or severe functional mitral regurgitation. Approximately 610 subjects will be randomized at up to 100 investigational sites with approximately 305 subjects targeted to receive the study device. COAPT study completed recruiting subjects in June 2017. As part of the COAPT trial, a subset of patients will be registered in the cardiopulmonary exercise (CPX) sub-study. The objective of this sub-study is to evaluate the exercise responses in a sub-cohort of COAPT subjects who receive MitraClip device (Device group) compared to the Control group who do not receive MitraClip device. (Note: the CPX Sub-study subjects will contribute to the analyses of the COAPT primary and secondary endpoints) As an extension of the COAPT RCT trial, COAPT CAS study will be conducted after COAPT enrollment is complete under the same investigational device exemption (IDE(G120024)). The objective of this study is to evaluate the MitraClip® NT System for the treatment of clinically significant functional mitral regurgitation (FMR) in symptomatic heart failure subjects who are treated per standard of care and who have been determined by the site's local heart team as not appropriate for mitral valve surgery. The anticipated Study Completion Date is July 2024. COAPT CAS completed recruiting subjects in March 2019.

UNKNOWN
Confirmation Trial of the Acorn CorCap Cardiac Support Device (CSD) at the Same Time as Mitral Valve Repair
Description

The purpose of this study to evaluate patients when they have an Acorn CorCapTM Cardiac Support Device (CSD) placed around their heart for the treatment of heart failure at the same time as their mitral valve surgery. The CorCapTM CSD is intended to support the heart, potentially preventing further dilation that is associated with progressive heart failure, thereby potentially preserving or improving heart function.

Conditions
TERMINATED
Effectiveness of Surgical Mitral Valve Repair Versus Medical Treatment for People With Significant Mitral Regurgitation and Non-ischemic Congestive Heart Failure
Description

Mitral regurgitation (MR), also known as mitral insufficiency, is a condition in which the heart's mitral valve, located between two of the heart's main chambers, does not firmly shut, allowing blood to leak backwards within the heart. Improper functioning of the mitral valve disrupts the proper flow of blood through the body, resulting in shortness of breath and fatigue. When mild, MR may not pose a significant danger to a person's health, but severe MR may be associated with serious complications, such as heart failure, irregular heart rhythm, and high blood pressure. Although there are treatments for MR, including medication and surgery, more information is needed on the effectiveness of these treatments in people with significant MR. This study will compare the safety and effectiveness of corrective surgery added to optimal medical treatment (OMT) versus OMT alone in treating people with significant MR caused by an enlarged heart.

WITHDRAWN
Effects of Mitral Valve Repair With the Geoform Ring on Cardiomyopathy
Description

The primary aim of this study is to assess the changes on the shape and function of the left ventricle in patients with severe mitral valve regurgitation due to congestive heart failure and cardiomyopathy who undergo mitral valve reconstruction with a Geoform ring. Three-dimensional echocardiogram will be used for precise evaluation of the shape and function of the ventricle.

COMPLETED
Feasibility Study of a Percutaneous Mitral Valve Repair System.
Description

Prospective, multi-center, Phase I study of the Evalve Cardiovascular Valve Repair System (CVRS) in the treatment of mitral valve regurgitation. Patients will undergo 30-day, 6 month, 12 month, and 5 year clinical follow-up.

COMPLETED
Pivotal Study of a Percutaneous Mitral Valve Repair System
Description

EVEREST II Randomized Controlled Trial (RCT) is a prospective, multi-center, randomized study of the MitraClip® System in the treatment of mitral valve regurgitation, randomizing patients to MitraClip or mitral valve surgery. The EVEREST II High Risk Registry (HRR) study is a prospective multi-center study of the MitraClip System for the treatment of mitral valve regurgitation in high surgical risk patients. Enrollment in the RCT and HRR is closed. A continued access prospective, multi-center study (REALISM) of the MitraClip System in a surgical population (non-high risk arm) and a high surgical risk population (high risk arm) is ongoing. Enrollment in the non-high risk arm of REALISM is closed. Enrollment in the high risk arm of REALISM is ongoing. Patients enrolled in EVEREST II undergo 30-day, 6-month, 12-month, 18-month and 24-month clinical and echocardiographic follow-up, and then annually for 5 years.

COMPLETED
RESTOR-MV: Randomized Evaluation of a Surgical Treatment for Off-Pump Repair of the Mitral Valve
Description

The purpose of this prospective, randomized, multi-center, pivotal trial is to compare the safety and effectiveness of the off-pump, closed heart Coapsys System (Myocor, Inc.) to open surgical repair of the mitral valve using an annuloplasty ring or band in patients with moderate to severe functional mitral regurgitation.

WITHDRAWN
Structural Heart and Valve Network PROSPECTIVE Registry
Description

Background: Treatments for structural heart and valve disease are quickly changing. But treatment could be improved. Researchers want to gather data from people with this disease. They want to find problems and seek new ways to make treatments better. Objective: To find people with structural heart and valve disease with common features to study. To find flaws and patterns in procedures related to this disease. To share findings with other researchers. Eligibility: People ages 18 and older who are receiving care from the structural heart and valve program at the participating NHLBI structural heart disease network sites that are part of the study Design: Participants will be screened with their consent. This will occur when they give their standard consent for medical care. Participants will have their data collected in the course of standard medical care. Data include: Demographic data Protected health data Personally identifiable data Medical records Medical images. These could include X-rays, CT scans, and MRI scans. The study could find something that would impact participants care. If this is the case, their doctors will be told. Participants data may be shared with other researchers. ...

COMPLETED
EVEREST II Pivotal Study High Risk Registry (HRR)
Description

Prospective, multi-center, single arm registry. Clinical follow-up at discharge, 30 days, 6, 12, 18 and 24, months, and 3, 4 and 5 years. Concurrent Control (CC) group identified retrospectively from the patients screened for the HRR who did not enroll; patient survival determined at 12 months. NCT00209274 (EVEREST II RCT) Intended use Percutaneous reduction of clinically significant mitral regurgitation in symptomatic patients who are considered to be high risk for operative mortality (high surgical risk).

COMPLETED
Real World Expanded Multicenter Study of the MitraClip® System (REALISM)
Description

Prospective, multicenter, continued access registry of the MitraClip® Cardiovascular Valve Repair System in the treatment of mitral valve regurgitation. Patients will undergo 30-day, 6-month, 12-month, 36-month and 60-month clinical follow-up. The study consists of two arms: a High Risk group (NCT01940120) and a Non-High Risk group (NCT00209274) . Patients that did not meet REALISM High Risk or Non-High Risk eligibility criteria were evaluated for consideration for either Emergency Use (EU) or Compassionate Use (CU).

COMPLETED
Cardiac Output Pulmonary Arterial Catheter Compared to FloWave™ 1000
Description

The purpose of this study is to compare cardiac output results obtained using the thermodilution push technique with the Pulmonary Arterial Catheter (PAC) to the predicted cardiac output results obtained from the non-invasive FloWave™ 1000 device.

UNKNOWN
VIVID - Valvular and Ventricular Improvement Via iCoapsys Delivery - Feasibility Study
Description

The purpose of this prospective, non-randomized, single-arm feasibility study is to evaluate safety and feasibility of the iCoapsys System in patients with functional mitral valve insufficiency caused by annular dilation and/or papillary muscle displacement.

TERMINATED
Improving Mitral Repair for Functional Mitral Regurgitation
Description

The investigators are interested in determining the best surgical technique to correct functional mitral regurgitation, as there is currently not one technique that is established to work better than the other. The technique used in current clinical practice is undersizing mitral annuloplasty (UMA), in which a prosthetic ring is implanted onto the mitral valve to correct the leakage. Though widely adopted, durability of the repair is less, as 58% of the patients present with recurrent FMR within 2 years. There are no specific algorithms to predict who might have UMA failure, but research indicates that some geometric indices might be strong predictors. The investigators are interested in testing the hypothesis that, elevated lateral inter-papillary muscle separation (IPMS) is a predictor of post-UMA recurrence of FMR at 12 months. In the first part of this study, the study team will measure lateral IPMS before surgery and relate to post-surgery FMR severity at discharge/30 days, 6 months and 12 months. A relatively newer technique is papillary muscle approximation (PMA), in which a suture draws together the two muscles that connect the mitral valve to the heart muscle prior to performing UMA. This reduces the lateral inter-papillary muscle separation (IPMS) and is expected to improve the durability of UMA. In the second part of this study, the investigators will perform PMA and UMA together and determine if FMR severity is reduced at discharge/30 days, 6 months and 12 months.

COMPLETED
Mitral Loop Cerclage(MLC) for Reducing Functional Mitral Regurgitation
Description

To evaluate safety and feasibility of Mitral Loop Cerclage(MLC) Annuloplasty with CSTV for repair of functional mitral regurgitation.

ACTIVE_NOT_RECRUITING
ProspeCtive, nOn-randoMized, MulticENter Clinical Evaluation of Edwards Pericardial Bioprostheses With a New Tissue Treatment Platform (COMMENCE)
Description

The objective of this trial is to confirm that the modifications to tissue processing, valve sterilization and packaging do not raise any new questions of safety and effectiveness in subjects who require replacement of their native or prosthetic aortic or mitral valve.

COMPLETED
Magna® Mitral Pericardial Bioprostheses Post-Approval Study Protocol
Description

The purpose of the study is to demonstrate the long term safety and effectiveness of the Carpentier-Edwards® PERIMOUNT Magna Mitral Valves in patients undergoing mitral valve replacement with or without concomitant procedures requiring cardiopulmonary bypass.