The purpose of this study is to provide supporting documentation of the blood pressure performance for the Philips EarlyVue VS30 monitor on the intended adult and pediatric population. The same arm sequential method with dual observer auscultation will be used to collect data.
The goal of this observational study is to evaluate the accuracy and reliability of the VeriTrack non-invasive blood pressure monitor compared to radial arterial catheterization in adult surgical patients. The main question it aims to answer is: How well does VeriTrack measure continuous blood pressure compared to an arterial catheter? Researchers will compare VeriTrack readings to arterial line measurements to determine if the VeriTrack provides comparable accuracy and clinical utility. Participants will wear the VeriTrack device during surgery and have a radial arterial catheter placed as part of standard care.
The purpose of this study is to calibrate the ViTrack™ arterial pressure waveform against intra-arterial pressure (IAP) in dynamic clinical settings and to assess the optimized ViTrack™ design to measure and continuously track blood pressure over a wide, clinically-relevant pressure range.
The purpose of this study is to provide supporting documentation of the blood pressure performance for the Philips EarlyVue VS30 monitor on the intended adult and pediatric population. The same arm sequential method with dual observer auscultation will be used to collect data.
Lifelight is a novel, calibration-free, software-only medical device that contactlessly measures pulse rate and blood pressure by measuring remote photoplethysmography (rPPG) signals of a patient's face using a standard smartphone or tablet camera. By conducting this validation study we aimed to demonstrate the accuracy of Lifelight for classifying the full range of clinically relevant blood pressures as hypertensive or non-hypertensive and demonstrate its accuracy for measuring pulse rate and the blood pressure of people with blood pressures relevant to Stage 1 hypertension.
The diagnosis of hypertensive disease during pregnancy is predicated on strict blood pressure thresholds: 140/90 on at least two occasions measured four hours apart for both gestational hypertension and preeclampsia. An improvement in diagnostic accuracy of even 5mm Hg would be significant, as reflected by the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring, and the International Organization for Standardization (ISO)consensus for validation of non-invasive blood pressure (NIBP) devices during pregnancy. Given the known inaccuracies of upper arm cylindrical cuff measurements in morbidly obese patients, a conical cuff which provides more accurate measurements will translate into direct patient benefit via more informed diagnosis and management. Fewer women may be exposed to unnecessary treatment, preterm delivery, and/or cesarean section. Recognizing the increasing prevalence of morbid obesity and hypertensive disease amongst pregnant women in the United States, the identification of a more accurate non-invasive cuff is desperately needed. Increasing the accuracy of NIBP measurements on Labor and Delivery has the potential to directly impact the management of tens of thousands of morbidly obese pregnant women diagnosed with hypertensive disease in the United States every year. Establishing the level of agreement between conical forearm and cylindrical upper arm cuffs will shed light on the presence and magnitude of any disparity between measurement methods. STUDY ENDPOINTS: Primary Outcome Measures: * Agreement between conical and cylindrical cuff systolic blood pressure across groups * Agreement between conical and cylindrical cuff diastolic blood pressure across groups Secondary Outcome Measures: • Agreement between conical and cylindrical cuff mean arterial pressure
The study intervention consists of a non-invasive blood pressure (NIBP) measurement device and cuff (FDA-cleared Philips IntelliVue X3 Rev. N.04 patient monitor) running a non-approved modified software containing an enhanced measurement algorithm for NIBP.
This study designed is compare the pulse response to the Valsalva maneuver between a photoplethysmography sensor (PPG) and non-invasive blood pressure sensor for the purpose of validating the PPG methodology in deriving a value for the Valsalva pulse response. The aim is to show that the PPG method captures the same phase responses as the blood pressure monitor and the primary outcome is the correlation between pulse amplitude ratios for the pulse at the end of the Valsalva to an average baseline pulse.
The purpose of this study is to evaluate methods to modify blood pressure in humans and measure the effectiveness of such methods. A secondary outcome is to evaluate the performance of an investigational continuous non-invasive blood pressure (cNIBP) device created by Sensifree. The tests will per performed in non-hospitalized subjects under varied controlled conditions that include resting blood pressure and non-pharmacologically induced blood pressure changes.
The primary objective of the study is to demonstrate the accuracy in healthy adults with Vital USA Device by comparison to a non-invasive (auscultatory) reference sphygmomanometer. The procedure, data collection methods and data analysis that are outlined in the protocol follow the standard: International Standards Organization (ISO) 81060-2:2018 Non-invasive Sphygmomanometers - Part 2: Clinical validation of automated measurement type.
The purpose of this study is to demonstrate equivalency of the GE Healthcare B40 Patient Monitor noninvasive blood pressure (NIBP) parameter compared to the reference device.
The purpose of this study is to establish the performance of a blood pressure cuff. The hypothesis is that the blood pressure reading from the cuff will provide similar blood pressure as a radial artery.
The purpose of this study is to compare the accuracy of the Sotera ViSi, an investigational device, to auscultation (measurement with a cuff) in determining systolic and diastolic blood pressure (BP) in adult subjects.
Blood pressure cuffs (NIBP) are slowly replacing intra-arterial (IABP) measurement as the standard of care in the medical intensive care unit. There is little data to support this clinical normalization of deviance. This study aims to correlate NIBP with IABP.
The accuracy and/or performance of the GE DINAMAP noninvasive blood pressure (NIBP) monitors may be improved with modifications in software and/or hardware monitoring techniques and/or accessories. When changes are being made to the GE Monitor, testing can be done to evaluate performance of the investigational devices during and/or after product development.
This protocol focuses on the evaluation of the GE noninvasive blood pressure parameter in subjects with dysrhythmias and normal sinus rhythm. The study follows the recommendations of the ANSI/AAMI SP10 Standard.
This is a prospective, nonrandomized multi-center study for the investigation of noninvasive sphygmomanometers. The purpose of the study is to validate the clinical performance of the Masimo noninvasive blood pressure device compared to reference auscultatory measurements.
The purpose of this study to collect blood pressure measurement values from the blood pressure measurement device on the Fresenius machine as compared to the standard method.
This study is required to demonstrate that the non-invasive blood pressure (NIBP) measurement algorithms on two commercially available multifunction hemodynamic acquisition modules, the Patient Data Module (PDM) equipped with the DINAMAP® SUPERSTAT algorithm ("PDM-SUPERSTAT") and the Patient Side Module (PSM) equipped with Datex-Ohmeda GE algorithm ("PSM-Datex-Ohmeda"), provide accurate NIBP measurements in accordance with the guidelines provided by the most recent International Organization for Standardization (ISO) 81060-2:2013. Notably, the new ISO 81060-2:2013 supersedes the previous 2009 version of this standard, and this study is being conducted in accordance with the most recent applicable standards. This study will assess neonate, infant, children, pediatric, adolescent, and adult patients as well as adults with chronic atrial fibrillation in a population that requires non-emergent heart catheterization. This is a study conducted to satisfy both standards for two NIBP devices and, as such, does not require a statistical hypothesis.
The primary objective of this study is to show that the noninvasive blood pressure software algorithm meets engineering requirements.
A randomized controlled trial compared the clinical outcomes of transported pediatric patients monitored with an oscillometric blood pressure device versus those monitored with a near-continuous, noninvasive blood pressure.
This investigation is a multi-center study that will demonstrate that the GE Monitor meets equivalency and/or accuracy and/or performance criteria. This investigation will compare the test device(s) to itself, or one of the reference parameters, or a combination of parameters, including NIBP, temperature, SpO2, respirations, and ECG.
The goal of this study is to evaluate if a novel near-infrared spectroscopy (NIRS) device can accurately estimate blood pressure in newborns at risk for unstable blood pressure. The main questions it aims to answer are: * Can NIRS accurately estimate blood pressure when compared to the gold standard, arterial line blood pressure * Can NIRS accurately estimate blood pressure when compared to infants with cuff blood pressure monitoring Researchers will compare NIRS-based estimates to arterial line blood pressure readings and manual cuff measurements to optimize and validate the FlexNIRS device for neonates to accurately estimate blood pressure continuously and noninvasively. Participants will wear a small, noninvasive NIRS sensor on the forehead.
The goal of this observational study is to assess the validity of a continuous non-invasive blood pressure monitoring device, Acumen IQ cuff (Edwards Lifesciences LLC, Irvine, CA), when used on the toe in healthy volunteers. The main questions it aims to answer is: • Can a continuous non-invasive blood pressure monitoring device accurately measure hemodynamic parameters when placed on a toe as compared to the finger in a healthy volunteer? Secondary Outcomes: * What are the effects of length and circumference of the middle phalanx of the 2nd toe on the accuracy of the Acumen IQ cuff (Edwards Lifesciences LLC, Irvine, CA) measurements compared to the measurements taken from the finger? * What are the effects of a Valsalva maneuver on the measurements taken from the Acumen IQ cuff (Edwards Lifesciences LLC, Irvine, CA) on a toe compared to the Acumen IQ cuff (Edwards Lifesciences LLC, Irvine, CA) placed on the finger. Participants will: * Have blood pressures taken using an automatic blood pressure cuff (both arms and both calves) * Have a continuous non-invasive blood pressure monitoring sensor placed on their finger and toe simultaneously for 10 minutes * Be asked to valsalva briefly to induce a change in blood pressure to be observed by the dual sensors
Pulmonary arterial hypertension (PAH) and chronic thromboembolic pulmonary hypertension (CTEPH) are severe clinical conditions that, despite advances in therapeutics over the past 20 years, lead to serious morbidity and mortality. Guidelines on the diagnosis and treatment of pulmonary hypertension (PH) recommend the use of a multiparametric risk stratification tool to determine severity of disease, which should guide initial therapy and therapy modulation. This multiparametric risk stratification schema includes objective assessment of exercise capacity, right ventricular function and hemodynamic parameters in order to classify patients into severity categories. Cardiac index (CI) and right atrial pressure (RAP), measured via right heart catheterization (RHC), are the hemodynamic parameters used in risk assessment of PH. Arguably, stroke volume index (SVI) is the most important hemodynamic parameter for assessment of PH severity and there is currently no validated method for noninvasive measurement of cardiac output (CO), CI or SVI. Currently, a major obstacle in the field is that hemodynamic measurements are not obtained on a regular basis in the risk assessment and therapy modulation of patients with PAH and CTEPH. If a noninvasive method of hemodynamic measurement could be correlated with other objective measurements of risk assessment, it could become an invaluable tool in therapy initiation and modulation in the ambulatory setting. This is a single center study to evaluate the use of non-invasive measurement of CO and stroke volume to assess risk and response to treatment in patients with PAH and non- operable CTEPH. We anticipate to enroll a total of 100 subjects at Ronald Reagan UCLA Medical Center. A maximum of 10 hour in total for the study including the consent process, pre-procedure care, RHC procedure, and follow up visit. The initial visit will be approximately 4 hours with the RHC procedure itself will only be 20 minutes. Each follow up visit will be 1.5 hour. Patients with known or suspected PAH or CTEPH will undergo a RHC as part of his or her standard of care. Three techniques of CO measurement will be performed sequentially at the time of the RHC. The device that will be used is the Edwards ClearSight system and EV1000 clinical platform, a device that measures NIBP. Patients will be followed over the period of 1 year every 3 months to obtain serial measurements for six-minute walk distance (6MWD), World Health Organization (WHO)/New York Heart Association Functional Class (FC), B-type natriuretic peptide (BNP) or N-terminal-pro hormone BNP (NT-proBNP), and non-invasive hemodynamic measurements. Additional visits will be scheduled to obtain the serial measurements one month prior and one month following if a patient is initiating or changing PH-specific therapy. As this is a study looking at the feasibility of non-invasive measurement of cardiac output and stroke volume for risk assessment and response to therapy in pulmonary arterial hypertension (PAH) or chronic thromboembolic pulmonary hypertension (CTEPH), study personnel performing the study procedures will not be blinded to the clinical diagnosis and the management of the subject.
Pulmonary embolism impacts over 1 in 1000 adults annually and is the third leading cause of cardiovascular death after heart attack and stroke. The consequence of each PE is widely variable. Physiologically, the morbidity and mortality of PE is ultimately caused by failure of the right ventricle. The acute rise in pulmonary vascular resistance caused by a PE can overwhelm the right ventricle, resulting in a drop in cardiac output and death from failure of the heart to provide vital perfusion. Despite the importance of stroke volume and cardiac output in the current understanding of PE mortality, they are notably absent from risk stratification scores because they historically could only be measured invasively. Novel non-invasive methods of estimating stroke volume and associated cardiac output have the potential to revolutionize PE risk stratification and care. Non-invasive blood pressure (NIBP) monitors can even measure stroke volume beat to beat, allowing for continuous evaluation of cardiac function. NIBP systems are typically composed of a finger cuff with an inflatable bladder, pressure sensors, and light sensors. An arterial pulse contour is formed using the volume clamp method of blood pressure measurement combined with calibration and brachial pressure reconstruction algorithms. The stroke volume with each heart beat can be estimated as the area under the systolic portion of the blood pressure curve divided by the afterload. NIBP monitors may improve clinical care of PE because they allow for assessment of dynamic cardiac changes in real time. Detection of worsening stroke volume in acute PE could inform providers of impending cardiac collapse, and improvement of stroke volume may function as a positive prognostic factor or marker of therapeutic success. Use of NIBP monitors during acute PE to identify clinically significant changes in cardiac function may advance both PE prognostication and management. Our clinical study proposes to monitor hemodynamic parameters including stroke volume in patients with acute pulmonary embolism using non-invasive blood pressure monitors. The relationship between hemodynamic parameters and PE outcomes will be assessed, as well as the changes in hemodynamic parameters with PE intervention. To our knowledge, interval monitoring of stroke volume during acute PE with NIBP monitors has never been reported before.
The primary objective of this study is to collect training data in order to establish a method for correlating arterial blood pressure with voltage output signals from a non-invasive piezoelectric array sensor placed on the skin superficial to the radial artery.
This is a prospective observational study to investigate if a non-invasive blood pressure monitoring device, the CareTaker Pulse Decomposition Analysis (PDA), can accurately measure blood pressure in children when compared to an arterial line. Enrolled patients will have the CareTaker PDA device placed on their finger during their operation to collect data for 30 minutes. Blood pressure readings from the CareTaker PDA device will be compared to measurements from the patient's indwelling arterial line, which will be placed as part of the patient's clinical care plan.
This protocol will test a new non-invasive device, the T-line, in continuously determining heart rate and blood pressure in operative and critically ill patients. The accuracy of the device will be compared to the standard radial artery catheter, as well as to the non-invasive blood pressure cuff. The T-line will also be compared to the right heart catheter determining cardiac output in at least 20 patients. Hypothesis: the T-line device will determine blood pressure and heart rate as accurately as a standard radial arterial catheter and a blood pressure cuff in perioperative patients.
The investigator's objective is to validate the novel automated blood pressure device against the requirements set forth in the AAMI_ISO 81060-2:2010 standard in voluntarily consented study participants.