RECRUITING
A Study of Assessment on Safety and Effectiveness of BWI Pulsed Field Ablation With OMNYPULSE Catheter for the Treatment of Paroxysmal Atrial Fibrillation (PAF)
Description

The purpose of this study is to demonstrate the safety and 12-month effectiveness of the BWI OMNYPULSE™ pulsed field ablation (PFA) platform for pulmonary vein isolation (PVI) in the treatment of participants with symptomatic paroxysmal atrial fibrillation (PAF), an irregular heart rate that causes abnormal blood flow.

RECRUITING
Posterior Wall Substrate Modification Using Irreversible Electroporation for Paroxysmal Atrial Fibrillation
Description

The purpose of this study is to compare the efficacy and safety between pulmonary vein isolation (PVI) alone versus PVI with left atrial (LA) posterior wall isolation (PWI) using pulsed-field ablation (PFA) in the treatment of patients with paroxysmal atrial fibrillation (PAF).

RECRUITING
The Long-term Safety and Effectiveness Evaluation of the QDOT MICRO System Use in Conjunction With VISITAG SURPOINT Module for the Treatment of Symptomatic Drug Refractory Paroxysmal Atrial Fibrillation.
Description

Observational, multi-center, non-randomized, post-market study. This is a nested sub-study of the REAL AF Registry. Consecutive symptomatic drug refractory paroxysmal atrial fibrillation (PAF) patients from the registry will be screened for enrollment to this sub-study per inclusion and exclusion criteria.

COMPLETED
The FARAPULSE ADVENT PIVOTAL Trial PFA System vs SOC Ablation for Paroxysmal Atrial Fibrillation
Description

This is a prospective, adaptive, multi-center, randomized safety and effectiveness pivotal study comparing the FARAPULSE Pulsed Field Ablation System with standard of care ablation with force-sensing RF catheters and cryoballoon catheters indicated for the treatment of PAF.

COMPLETED
Clinical Evaluation of the StablePoint Catheter and Force Sensing System for Paroxysmal Atrial Fibrillation
Description

The NEwTON AF study is a multi-center, global, prospective, single arm study to establish the safety and effectiveness of the IntellaNav StablePoint Catheter and Force-Sensing System in subjects with symptomatic, drug refractory, recurrent paroxysmal atrial fibrillation.

COMPLETED
TactiFlex Paroxysmal Atrial Fibrillation IDE Trial
Description

Prospective non-randomized parallel-assignment multi-center clinical investigation. The study design includes two subject cohorts: 1) Paroxysmal Atrial Fibrillation Main Study, and 2) Paroxysmal Atrial Fibrillation High Standard Power Substudy. Subjects in the main study cohorts are to be treated using the full range of ablation power settings in the Instructions For Use. Subjects in the High Standard Power Substudy are to be treated in the upper end of the recommended ablation power settings (40-50 Watts).

TERMINATED
Posterior Wall And Left Atrial Appendage Empiric Electrical Isolation for Non-Paroxysmal Atrial Fibrillation
Description

The purpose of this study is to evaluate the safety and effectiveness of empirical posterior wall isolation (PWI), left atrial appendage electrical isolation (LAAEI) and coronary sinus isolation (CSI) when compared to pulmonary vein isolation (PVI) alone: * PVI alone, * PVI + PWI, * PVI + PWI + LAAEI, * PVI + PWI + LAAEI + CSI.

COMPLETED
Boston Scientific's Cryoballoon in the Treatment of Symptomatic Drug Refractory Paroxysmal Atrial Fibrillation
Description

To establish the safety and effectiveness of the Boston Scientific Cardiac Cryoablation System for treatment of symptomatic, drug refractory, recurrent, paroxysmal atrial fibrillation (AF).

ACTIVE_NOT_RECRUITING
Meditation and Education That is Nurse Delivered for Symptom Management in Paroxysmal Atrial Fibrillation (PAF)
Description

The aim of this project is to determine whether the entire intervention (Mindfulness meditation, AF education, and weekly phone visits) that is nurse delivered to individuals with paroxysmal atrial fibrillation is more effective than a combination, single or no intervention in the reduction of overall AF symptoms, anxiety, and negative illness perception; or the improvement of quality of life (QOL) and functional status.

COMPLETED
Evaluation of QDOT MICRO™ Catheter for Pulmonary Vein Isolation in Subjects With Paroxysmal Atrial Fibrillation
Description

Prospective, non-randomized, pre-market clinical evaluation of the QDOT MICRO™ Catheter to demonstrate the safety and effectiveness when compared to an historical control performance goal.

COMPLETED
Prospective Evaluation of Open Irrigated Ablation Catheters With High Resolution Mapping to Treat Paroxysmal Atrial Fibrillation
Description

To obtain data for the Rhythmia™ Mapping System in conjunction with Boston Scientific Open-Irrigated (OI) Catheters for ablation of Paroxysmal Atrial Fibrillation (PAF) according to current international and local guidelines. Primary objective: To assess acute and long-term outcomes for the Rhythmia Mapping System in conjunction with Boston Scientific Open-Irrigated Ablation Catheters to treat de novo Paroxysmal Atrial Fibrillation. De Novo PAF is defined as subjects undergoing first ablation procedure for PAF with no prior left atrial ablation (RF, Cryo, Surgical).

COMPLETED
Safety and Effectiveness Evaluation of the Multi-Electrode Radiofrequency Balloon Catheter for the Treatment of Symptomatic Paroxysmal Atrial Fibrillation
Description

The primary objective of this clinical investigation is to demonstrate safety and effectiveness of the Multi-Electrode RF Balloon catheter for the treatment of drug refractory symptomatic paroxysmal atrial fibrillation.

COMPLETED
Low-Level EMF Stimulation for Paroxysmal Atrial Fibrillation
Description

This research has two main specific aims. First, a commercially-available stimulator will be utilized to assess the effect of low-level electromagnetic field (EMF) stimulation on atrial fibrillation (AF) inducibility in patients with paroxysmal AF presenting for catheter ablation as compared to sham stimulation. We hypothesize a reduction in AF inducibility in patients treated with EMF stimulation. Second, we aim to assess for the effect of low-level EMF on level of systemic inflammatory mediators. We hypothesize a reduction in the level of the inflammatory mediator tissue necrosis factor (TNF)-α in patients treated with EMF stimulation as compared to sham stimulation. The long-term objective of this research is to develop low-level EMF as a therapeutic alternative for patients with AF, and this research will help to determine the efficacy of low-level pulsed EMF in this regard.

COMPLETED
SMART Program for Paroxysmal Atrial Fibrillation
Description

This is a pilot study to test the effects of the SMART-3RP (Stress Management and Resiliency Training Relaxation Response Resiliency Program) on quality of life, mental health, arrhythmia burden, and heart rate variability (HRV) in patients with paroxysmal atrial fibrillation (PAF).

COMPLETED
TactiSense IDE Trial of TactiCath SE for Paroxysmal Atrial Fibrillation
Description

This clinical investigation is intended to demonstrate the acute safety and effectiveness of ablation with the TactiCath™ Contact Force Ablation Catheter, Sensor Enabled™ (TactiCath SE) for the treatment of drug refractory recurrent symptomatic paroxysmal atrial fibrillation (PAF). This clinical investigation will be conducted under an investigational device exemption (IDE) and is intended to support market approval of the TactiCath SE ablation catheter in the United States. One hundred fifty six (156) subjects will be enrolled at up to 35 investigational sites in the US, Europe, and Australia. This clinical investigation is sponsored by Abbott.

COMPLETED
DiamondTemp™ Ablation System for the Treatment of Paroxysmal Atrial Fibrillation
Description

The purpose of the DIAMOND-AF study is to establish the safety and effectiveness of the DiamondTemp System for the treatment of drug refractory, recurrent, symptomatic paroxysmal atrial fibrillation in patients.

COMPLETED
Individualized Studies of Triggers of Paroxysmal Atrial Fibrillation
Description

The I-STOP-Afib study will test the comparative effectiveness of using N-of-1 trials vs. symptom surveillance alone to reduce Atrial Fibrillation (AF) episode frequency and severity and improve quality of life for AF patients. The study will involve randomizing almost 500 paroxysmal AF patients to either AF episode tracking versus engaging in testing the relationship between participant-selected triggers and AF episodes utilizing a mobile-app based N-of-1 study design. Both groups will complete a validated survey to assess AF severity, essentially a measure of quality of life while living with AF, before and after a 3 month testing period.

COMPLETED
STOP AF First: Cryoballoon Catheter Ablation in an Antiarrhythmic Drug Naive Paroxysmal Atrial Fibrillation
Description

To provide data demonstrating the safety and effectiveness of the Arctic Front Advance™ Cardiac CryoAblation Catheter for the treatment of recurrent symptomatic paroxysmal atrial fibrillation, without the requirement that the subjects be drug refractory.

TERMINATED
Comparison of PVI Plus Catheter Ablation or PVI Alone for the Treatment of AFib for Patients With Paroxysmal Atrial Fibrillation
Description

There is a need to compare the efficacy of PVI versus PVI plus catheter ablation, which includes ablation of complex fractionated atrial electrograms (CFAE) and linear lesions in the same procedure. If it is found that the PVI alone is as effective as PVI plus catheter ablation of CFAE and linear lesions, it may reduce the need for catheter ablation.

COMPLETED
Adenosine to Assess Complete Conduction Block During Catheter Ablation of Paroxysmal Atrial Fibrillation
Description

The purpose of this study is to determine if additional ablation during the first procedure as the result of the ability to medically induce quiet atrial arrhythmias will improve clinical outcome in patients with atrial fibrillation thus decreasing the need for additional ablation procedures.

COMPLETED
Occult Paroxysmal Atrial Fibrillation in Non-Cryptogenic Ischemic Stroke
Description

The purpose of this study is to determine the incidence of paroxysmal atrial fibrillation (AF) in ischemic stroke patients who have a presumed known stroke etiology other than atrial fibrillation.

Conditions
UNKNOWN
Substrate Versus Trigger Ablation for Paroxysmal Atrial Fibrillation
Description

This is a prospective randomized study to assess the safety and efficacy of FIRM (Focal Impulse and Rotor Modulation)-guided ablation for the treatment of symptomatic atrial fibrillation (AF). The study hypothesis is that the efficacy of AF elimination at 1 year will be higher by ablating patient-specific AF-sustaining rotors and focal sources by Focal Impulse and Rotor Modulation (FIRM) compared to conventional ablation alone (wide-area PV isolation).

TERMINATED
A Blinded Study to Evaluate Effect on Atrial Fibrillation Burden in Patients With Paroxysmal Atrial Fibrillation
Description

The purpose of this study is to evaluate the effect of BMS-919373 on atrial fibrillation (AF) through its effect on AF burden (AFB), or the percent of time in AF, in subjects with paroxysmal AF (pAF) when administered orally at a range of doses (2 mg once daily (QD), 5 mg QD, 12 mg QD following a 1-week period of loading doses of 3 mg QD, 8 mg QD and 20 mg QD, respectively) for a total of 4 weeks. It is hypothesized that treatment with BMS-919373 will reduce AF burden as compared to baseline relative to placebo.

COMPLETED
Effectiveness Study of Circumferential vs. Segmental Ablation in Paroxysmal Atrial Fibrillation
Description

This is a PI-initiated study that aims to evaluate the efficacy of two different methods of paroxysmal atrial fibrillation (PAF) ablation. There are currently two strategies for PAF ablation that are routinely performed by electrophysiology clinicians: (1) circumferential pulmonary vein ablation (CPVA) and (2) segmental pulmonary vein isolation (SPVI). However, it is not known if one approach is better than the other. This randomized study will evaluate and compare the efficacy of CPVA versus SPVI in subjects undergoing ablation for paroxysmal atrial fibrillation only. Subjects will have a 50/50 chance of receiving either the CPVA or SPVI ablation method.

COMPLETED
Pilot Study Evaluating the Toray Satake Balloon Thermal Ablation System for Treatment of Paroxysmal Atrial Fibrillation
Description

The purpose of this study is to collect preliminary safety and effectiveness data evaluating the Toray Satake Balloon Thermal Ablation System (TSB)to treat subjects with symptomatic paroxysmal atrial fibrillation that is resistant to antiarrhythmic drug therapy.

TERMINATED
Focal Impulse and Rotor Modulation Ablation Trial for Treatment of Paroxysmal Atrial Fibrillation (FIRMAT-PAF)
Description

* Hypothesis: Focal Impulse and Rotor Modulation (FIRM) will substantially reduce or eliminate clinical atrial fibrillation in subjects with accepted indications for catheter ablation of paroxysmal AF, compared to standard pulmonary vein isolation. * Summary: This is a prospective randomized study to assess the safety and effectiveness of FIRM procedures only, versus standard Pulmonary Vein Isolation (PVI) procedures for the treatment of symptomatic paroxysmal atrial fibrillation.

TERMINATED
nMARQ™ Pulmonary Vein Isolation System for the Treatment of Paroxysmal Atrial Fibrillation
Description

To demonstrate safety and effectiveness of nMARQ Catheter System \[nMARQ\] compared with THERMOCOOL® Navigational Family of catheters in treating subjects with drug-refractory symptomatic paroxysmal atrial fibrillation (PAF).

COMPLETED
ABLATE Post Approval Study - Synergy Ablation Lesions for Non-Paroxysmal Atrial Fibrillation
Description

The primary objective of this post-approval study is to evaluate the clinical outcomes in a cohort of patients with non-paroxysmal forms of atrial fibrillation (persistent or long-standing persistent) treated during commercial use of the AtriCure Synergy Ablation System by physicians performed the Maze IV procedure.

COMPLETED
Clinical Evaluation of the Blazer Open-Irrigated Ablation Catheter for the Treatment of Paroxysmal Atrial Fibrillation
Description

The purpose of this study is to establish the safety and effectiveness of the Blazer Open-Irrigated radiofrequency ablation catheter for the treatment of drug refractory, recurrent, symptomatic, paroxysmal atrial fibrillation.

UNKNOWN
Pulmonary Vein Antrum Isolation (PVAI) Plus Scar Homogenization and Non-PV Triggers Ensure Long-term Recurrence-free Survival in Non-paroxysmal Atrial Fibrillation
Description

This study aims to examine the long-term success rate of catheter ablation in non-paroxysmal atrial fibrillation patients using different ablation strategies such as : (i) pulmonary vein antrum isolation (PVAI) + isolation of left atrial posterior wall, (ii) PVAI plus scar homogenization, (iii) PVAI plus isolation of posterior wall plus ablation of non-PV triggers \[ PVAI: Pulmonary Vein Antrum Isolation Non-PV triggers: Triggers arising from sites other than pulmonary veins\]