Treatment Trials

13 Clinical Trials for Various Conditions

Focus your search

COMPLETED
Natural Evolution of AV Conduction Disorders in Patients Implanted With Cardiac Pacemakers
Description

Observational study to assess AV block incidence and their evolution according to paroxysmal atrial arrhythmia.

ENROLLING_BY_INVITATION
Magnetic Resonance Imaging (MRI) in Patients With Pacemakers and Implanted Cardioverter Defibrillators
Description

Ferromagnetic Implants such as permanent pacemakers (PPM's) and Implantable Cardioverter Defibrillators (ICD's) have traditionally been accepted as contraindications to Magnetic Resonance Imaging (MRI) due to safety concerns. Over the past several years, MRI safety has been established in patients with pacemakers or ICD's but only in patients in whom strict vetting procedures were implemented. These vetting procedures were initially developed to eliminate devices, leads and device/lead circumstances thought to carry increased risk. Over recent years however, objective scientific evidence has failed to support this concern raising the question as to whether or not these vetting procedures are necessary. Investigators hypothesize that in view of the existing objective scientific data, evolution of device technology and the fact that the investigators have scanned more than 2,000 devices safely (RPN03-08-11-12 and 00051707) ICD's and pacemakers and device circumstances previously excluded from MRI protocols can be safely scanned without prior vetting. This is a prospective, non randomized, cohort study. Seventeen Hundred participants with an implanted ICD or pacemaker and a clinical need for MRI will be included in the study. Unlike previous studies where strict vetting procedures were implemented pre-procedure, All patients with a pacemaker or ICD and clinical need for an MRI will be eligible for inclusion in the study provided participants meet standard MRI inclusion/exclusion safety criteria.

Conditions
COMPLETED
University Hospital Cardiac Device MR Registry: The Safety of MR Imaging in Patients With Implanted Cardiac Devices
Description

A single-center registry to prospectively evaluate the safety of non-cardiac/non-thoracic magnetic resonance imaging (MRI) in patients with implanted cardiac devices (pacemakers and implantable cardioverter defibrillators).

COMPLETED
Myocardial Injury in Patients With Cardiac Implantable Electronic Devices Following Magnetic Resonance Imaging
Description

Researchers are trying to determine if heart injury occurs in subjects with cardiac implantable electronic device (CIED), such as a pacemaker or implantable cardioverter defibrillator (ICD), who undergo a magnetic resonance imaging (MRI).

COMPLETED
Safety and Clinical Outcomes of Magnetic Resonance Imaging in Patients With Cardiac Implantable Electrical Devices
Description

This protocol outlines a prospective study evaluating safety and clinical outcomes of magnetic resonance imaging (MRI) examinations performed on patients with cardiac implantable electrical devices (CIEDs) including pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs). This prospective study aims to improve the evidence base regarding this common clinical scenario. Specifically, the investigators aim to address whether results of MRI in PM/ICD patients affect physician decision making related to clinical management strategy and planning treatment interventions. Further, this study will evaluate whether the results of MRI in these patients affects patient outcomes related to survival and adverse events during or after MRI scanning.

Conditions
COMPLETED
Truncal Ultrasound Guided Regional Anesthesia for Implantation and Revision of Automatic Implantable Cardioverter Defibrillators (AICDs) and Pacemakers in Pediatric Patients
Description

The purpose of this study is to determine the efficacy and safety of truncal blocks for pacemaker and Automatic Implantable Cardioverter Defibrillator implantation in children and to prospectively evaluate whether there is a decrease in amount of narcotic medications need and track complications.

NOT_YET_RECRUITING
An Intervention to Impact Cardiovascular Implantable Electronic Device Lead Models Implanted in Veterans
Description

This study will evaluate if an intervention using academic detailing and audit and feedback impacts the specific pacemaker or implantable cardioverter-defibrillator (ICD) lead models implanted in Veterans.

Conditions
COMPLETED
Study Evaluating the Use of MRI on CMS Patients
Description

The overall objective of this protocol is to evaluate the safety and utility of diagnostic MRI in Center for Medicare and Medicaid Services (CMS) beneficiaries with pacemakers and Implantable Cardioverter Defibrillators (ICD) and clinical need for MRI.

WITHDRAWN
Patients With Patent Foramen Ovale and Endocardial Device Leads on Apixaban for Prevention of Paradoxical Emboli
Description

Patients with a patent foramen ovale in the setting of endocardially placed cardiac implantable electronic devices such as pacemakers, defibrillators, or resynchronization therapies are likely at higher risk for paradoxical embolic events from device lead thrombus. The investigators are conducting this study to determine if the anticoagulant medication Apixaban is more effective at reducing MRI detected brain lesions compared to placebo.

COMPLETED
Registry of Patients for MRI With Non-MRI Conditional Pacemakers and ICD Non-MRI Conditional Pacemakers and ICD
Description

The purpose of the registry is to accumulate pre-and post-scan device interrogation data for the purpose of determining the risk of MRI for patients with implantable devices.

COMPLETED
Study to Monitor Patients With Pacemakers or ICDs Who Undergo MRI Scans
Description

This study is a prospective, non-randomized, unblinded case series of patients with permanent pacemakers and implantable cardioverter-defibrillators undergoing medically-required magnetic resonance imaging (MRI) scanning, at St. Mary's Medical Center, Essentia Health. Patients will be enrolled over a 60-month period and followed for 12 months, with data collected to evaluate the study's primary endpoint, change in pacing thresholds over time, as well as a series of secondary endpoints, including: adverse events, symptoms, need to make pacemaker programming changes, and possible artifacts created by the pacemaker systems on the MRI scans. This study will allow for carefully monitoring of the safety MRI scanning in this population and improve practice models and protocols in the future.

COMPLETED
Apixaban for the Reduction of Thrombo-Embolism in Patients With Device-Detected Sub-Clinical Atrial Fibrillation
Description

This study aims to determine if treatment with apixaban, compared with aspirin, will reduce the risk of ischemic stroke and systemic embolism in patients with device-detected sub-clinical atrial fibrillation and additional risk factors for stroke.

COMPLETED
Randomized Study of the Use of Warfarin During Pacemaker or ICD Implantation in Patients Requiring Long Term Anticoagulation
Description

Patients requiring long term anticoagulation often undergo transition of their warfarin to heparin in anticipation of invasive surgical procedures such as pacemaker or ICD implantation. This may require inpatient hospitalization several days prior to and after the procedure, potentially increasing medical costs and patient inconvenience. Patients undergoing such a process are initiated on heparin while their INRs drift to normal levels. Immediately prior to surgery, heparin is discontinued and restarted several hours after the procedure. Unfortunately, this process has resulted in a high incidence of surgical wound hematomas and other bleeding complications often requiring longer periods of discontinued anticoagulation or repeat surgical exploration. Previous investigators have tried to reduce the incidence of wound hematomas by prolonging the time from surgical wound closure to the reinitiation of heparin. A small randomized trial demonstrated that there was no significant difference in the incidence of wound hematomas whether heparin was started 6 hours or 24 hours after surgery (J Am Coll Cardiology 2000;35:1915-8). This has led many investigators to perform pacemaker and ICD implantation without reversal of warfarin therapy. A recent retrospective observational study demonstrated that the incidence of wound hematomas in patients with an INR of 2.6 was no different than patients with an INR of 1.5 (PACE 2004;27:358-60). Furthermore, a more recent, larger retrospective observational study reported in abstract form at the recent Heart Rhythm Society Annual 2007 Scientific Meeting demonstrated that not only is performing pacemaker and ICD implantations safe without reversing warfarin anticoagulation, but the incidence of wound hematomas is significantly smaller as compared to the strategy of reversing warfarin and initiating periprocedural heparin. Given these findings, the hypothesis of this randomized study is that pacemaker and ICD implantation while fully anticoagulated on warfarin therapy is safe. Findings from this study will have significant implications on the clinical practice of pacemaker or ICD implantation in this patient population given that no randomized study on this subject has been performed to date.