Treatment Trials

17 Clinical Trials for Various Conditions

Focus your search

TERMINATED
A Study to Evaluate SU-VEID™ for Improving Peripheral Venous Access Success in Children
Description

The purpose of this study is to determine if use of the SU-VEID™ in children facilitates an increase success rate of peripheral intravenous starts, in comparison to the conventional method of vein entry techniques.

COMPLETED
Ultrasound Assisted Peripheral Venous Access in Young Children
Description

The purpose of this study is to learn how the use of ultrasound helps with the placement of an intravenous (i.v.) catheter in young children.

COMPLETED
Blood Sampling Functionality of Extended Dwell Catheters
Description

The purpose of this study is to compare upper arm versus forearm Extended Dwell Catheter (EDC) placement for blood sampling functionality. EDC is an alternative to peripheral Intravenous (IVs) especially during prolonged hospital stays. EDCs are generally placed using ultrasound for guidance and are commonly placed in any of 3 veins in the arm. They can be inserted above or below the antecubital fossa (the bend of the elbow). These catheters can be left for up to 30 days and don't fail as quickly when compared to peripheral IVs.

COMPLETED
Peripheral Internal Jugular Vein ('Peripheral IJ') Access in Patients Identified as Difficult Intravenous Access
Description

The primary aim of this study is to determine if the insertion of a peripheral Internal Jugular (IJ) catheter is faster than a standard of care intravenous (IV)access in patients with difficult access. The secondary aims of this study examine patient discomfort between standard IV insertion vs. peripheral IV insertion as well as a comparison of complication rates between the two methods of insertion. Support for the peripheral IV procedure could provide an option for the thousands of Emergency Department (ED) patients who daily encounter the situation of difficult IV access and the numerous needle pokes that accompany it. Using this procedure may result in greater patient satisfaction and reduced complication rates.

COMPLETED
The Effect of Tapping in the Venous Dilatation for Peripheral IV Access
Description

Peripheral intravenous cannulation (PIVC) is one of the most common interventions in medical practice. Venous dilatation is helpful for successful PIV placement. Several techniques include hot pack application, tourniquet, massaging, and tapping over the vein to increase vein caliber described in the literature. However, none of them has been rigorously studied. Therefore, there is still no 'best practice' on how to effect vein dilation in a standard way. This study aims to investigate the effect of standardized tapping on venous dilatation with a massage device compared to manual non-standardized tapping and define a standard tapping technique using a device. In this study, the investigators also aim to investigate the effect of tourniquet application with and without vein tapping effect on peripheral vein caliber as determined by ultrasound measurement.

ENROLLING_BY_INVITATION
Great Saphenous Vein Anatomy at the Proximal Medial Thigh as a Potential Site for Rescue Venous Access
Description

The purpose of this study is to assess the anatomy of the great saphenous vein at the level of the medial thigh in the general population in an effort to categorize this as a reliable target vessel for rescue peripheral IV access.

NOT_YET_RECRUITING
Long Versus Short Axis Approach for Ultrasound Guided Peripheral Intravenous Access
Description

To compare a long axis approach versus short axis when placing peripheral IVs using ultrasound guidance.

Conditions
TERMINATED
Veinplicity for Improved Venous Access: The VIVA Trial
Description

This study will assess the safety and effectiveness of the Veinplicity device to improve the visualization and palpability of difficult-to-access veins for intravenous cannulation.

COMPLETED
Use of Vein Viewer for Insertion of Peripheral Venous Cannula in Pediatric Patients With Difficult Intravenous Access
Description

The primary purpose of this prospective, randomized trial is successful intravenous (IV) cannulation on first attempt with the use of either the Vein Viewer (VV) or standard cannulation method. The secondary purpose is to find out if there is a difference in the total time to successful cannulation.

Conditions
UNKNOWN
Characteristics Predictive of Success and Complications in the Use of Suture-Mediated Closure of Femoral Venous Access
Description

Suture-mediated closure devices are effective and safe for achieving rapid hemostasis in femoral venous access site and reducing the incidence of complications associated with traditional closure methods. Furthermore, there are predictive factors(such as sheath size, obesity, procedure duration, and anticoagulation status)that we can use to assess the procedure's likelihood of success in various patients.

TERMINATED
Efficacy of Near-Infrared Vein Imaging for Difficult IV Placement
Description

The objective of this project is to define the effectiveness and therefore the role of NIR vein finders in adult patients with difficult peripheral venous access. The specific objective of the proposed randomized controlled trial is to test the clinical success rate of placing peripheral venous catheters in 'difficult' access patients using traditional peripheral venous catheter placement compared to two established methods utilizing NIR vein imaging. The investigators hypothesize that the capability to successfully place lasting peripheral venous catheters is increased with the adjunct of the imaging technology, reducing the number of failed needle sticks, reducing the number of peripheral venous catheters placed throughout a patient's hospital stay, and reducing the need for more invasive catheters such as PICC lines.

RECRUITING
Evaluating the Role of the Guidewire in Peripheral Intravenous Access: A Randomized Controlled Trial of Ultrasound-Guided Catheter Survival
Description

This is a prospective, parallel, non-blinded, two-arm randomized controlled trial of intravenous catheter failure evaluating the impact of a built-in guide wire. The objective of this study is to demonstrate that the control ultralong intravenous catheter (IV) without the guide wire is non-inferior to the experimental catheter with the guide wire. After obtaining consent, eligible patients will be randomly allocated to control Arm 1 (ultralong intravenous catheter) or experimental Arm 2 (ultralong intravenous catheter with guide wire) in a ratio of 1:1 via a computer-generated randomization schedule. The participants will be followed to collect data until the catheter is removed.

WITHDRAWN
Evaluating the Role of the Guidewire in Peripheral Intravenous Access
Description

This study is to demonstrate that the control ultralong intravenous catheter without the guide wire is equivalent to the experimental catheter with the guide wire. The hypothesis of this study is that the 6.35 cm 20G ultralong Ultrasound Guided Peripheral Intravenous (USPIV) will have no difference in survival compared to the 5.71 cm ultralong with wire USPIV.

COMPLETED
Ultrasound-guided Peripheral IJ Study
Description

Difficult venous access in some patients such as those with obesity, IV drug use, chronic illness, or vascular pathology often causes increased discomfort and delayed patient care due to multiple attempts to gain venous access. If access is achieved at all, it usually results in a much smaller catheter than needed to provide optimal care for the patient. Ultrasound-guided placement of a peripheral IV in the internal jugular vein is common in the investigators' emergency department and is gaining popularity across the US. This study investigates the utility and safety of placing an ultrasound-guided peripheral IV catheter in the internal jugular vein.

Conditions
COMPLETED
Correlation of Arterial and Venous Lactate and Base Deficit Values
Description

The purpose of this study is to determine the correlation between pH, base deficit, and lactate values when comparing venous and arterial blood samples in the pediatric population.

ENROLLING_BY_INVITATION
Outpatient Office Based Endovascular Procedures
Description

The results of this study will serve as a starting point for future trials concentrating on the effectiveness and clinical outcomes of the procedures performed in an office based angiosuite. Additionally, other studies could compare clinical outcomes between procedures performed in an office based angiosuite and other settings.

RECRUITING
Abbott Vascular Medical Device Registry
Description

The AV-MDR is a prospective, non-randomized, open-label, multi-center registry. The purpose of the AV-MDR study is to proactively collect and evaluate clinical data on the usage of the devices in scope within their intended use with the aim of confirming safety and performance throughout their expected lifetime, ensuring the continued acceptability of identified risks, detecting emerging risks on the basis of factual evidence, ensuring the continued acceptability of the benefit-risk ratio, and identifying possible systematic misuse or off-label usage such that the intended use can be verified as appropriate.