15 Clinical Trials for Various Conditions
The aim of the study is to evaluate the outcomes of the preloaded stent-graft design (PLD) in the routine treatment of para-renal and thoraco-abdominal aneurysms. Results and postoperative events are reported in accordance with the current reporting standards for endovascular aortic repair prepared and revised by the Ad Hoc Committee for Standardized Reporting Practices in Vascular Surgery of The Society for Vascular Surgery/American Association for Vascular Surgery. The Registry will include approximately 300 patients treated from January 2015 to May 2021 (retrospective arm) and June 2021 to June 2023 (perspective arm) for the routine treatment of para-renal and thoraco-abdominal aneurysms. To reach 300 patients, the enrollments can be extended until June 2026.
The purpose of this study is to evaluate the safety and efficacy of custom made devices, Zenith t-Branch devices and physician modification of FDA approved off-the-shelf endovascular grafts in the treatment of patients with complex abdominal aneurysms, aortoiliac aneurysms, thoracoabdominal aneurysms and aortic arch aneurysms who (1) have anatomy not suitable for endovascular repair using grafts currently marketed in the United States,(2) are deemed unsafe to wait the required time necessary for commercial endograft manufacturing, and (3) are at high risk for open surgical repair. Amendment to the study has created a cohort open to people with connective tissue diseases such as Marfan, Ehlers-Danlos or Loey-Dietz syndromes to enroll in the trial. An additional amendment to the study allows the use of a custom made device to treat an aneurysm in the aortic arch.
The purpose of this study is to evaluate the procedural and clinical benefits of patient specific pre-procedure rehearsal for operators with various experience levels as a tool for optimizing Endovascular Aneurysm Repair (EVAR) procedures.
The purpose of this study is to assess the role endovascular therapy to treat aortic disease involving the ascending aorta, the aortic arch, and the visceral segment of the aorta (or thoracoabdominal aorta)
The primary objective of the clinical investigation "Physician Modified Endovascular Grafts for the Treatment of Elective, Symptomatic or Ruptured Complex Aortic Aneurysms" is to assess the use of the Physician-Modified Endovascular Grafts to repair juxtarenal aneurysms in high-risk subjects considered to be high risk candidates for open surgical repair, have limited or no other options for on label treatment with an FDA approved device, and having appropriate anatomy.
The purpose of this randomized trial was to determine whether renal perfusion with cold blood provides better protection against renal ischemia than perfusion with cold crystalloid in patients undergoing TAAA repair with left heart bypass.
The purpose of this trial is to study the use of nesiritide in thoracic aneurysm repair to prevent acute renal failure. The study hypothesis: Nesiritide, given prophylactically prior to surgery may prevent acute renal failure requiring dialysis and/or decrease mortality.
This parallel-group, randomized, placebo-controlled study will examine the incidence and severity of acute kidney injury (AKI) in patients with chronic kidney disease (CKD) stage III/IV following an i.v. injection of iso-osmolar iodinated contrast material iodixanol (Visipaque™ Injection 320 mgI/mL), as compared with patients who received saline and underwent a non-enhanced CT (NECT) and duplex ultrasound (US) during their scheduled post-EVAR surveillance imaging.
The purpose of this trial is to determine if the Ventana Fenestrated Stent Graft System is safe and effective for the endovascular repair of juxtarenal or pararenal aortic aneurysms.
The aim of this study is to evaluate the safety and feasibility of the Endologix Fenestrated Stent Graft System for the endovascular repair of juxtarenal or pararenal aortic aneurysms.
The proposed study aims to evaluate the CNS penetration of telavancin in a critically ill population using cerebrospinal fluid (CSF) drawn from external ventricular drains (EVDs) in patients who have had spontaneous subarachnoid hemorrhage (SAH). Patients with SAH were chosen as the target population because they frequently require prolonged admission to the intensive care unit and drainage of CSF in order to prevent hydrocephalus. The estimated sample size is 20 subjects. This is a prospective cohort of patients with SAH. Patients will be included if they have a spontaneous SAH, aged 18-65 years old, Hunt-Hess score of 1-4 \& has an actively draining ventriculostomy. Subjects will receive telavancin 10mg/kg (maximum 1000mg) every 24 hours for 3 consecutive doses. Serial serum and CSF samples will be obtained. An 8-hour urine collection will be completed on study day 2 in order to define the patient's measured creatinine clearance.
This is a prospective clinical study of the VasQ external support for arteriovenous fistulas. The device is designed to improve fistula outcomes by optimizing the geometrical configuration of the fistula, influencing hemodynamics, minimizing turbulence and promote laminar flow. All patients will be implanted with the VasQ device and will be followed up for a duration of 24 months.
Summary 1. Purpose and Objective: The purpose of this study is to test the feasibility of rapid acquisition of point of care 3D ultrasound in obtaining abdominal and/or pelvic images. The study will use a newly developed acquisition method and post-processing technique to create three dimensional image models of the abdomen and/or pelvis. 2. Study activities and population group. The study population will be a convenience sample of patients of any age presenting to the Emergency Department with complaints necessitating a clinical abdominal and/or pelvic imaging. The study intervention includes acquisition of research ultrasound images, which will not be used for clinical care, and comparison of these images with clinically obtained images. Other clinical data such as surgical and pathology reports will also be reviewed. 3.Data analysis and risk/safety issues. This is a pilot study intended to determine feasibility and to refine image reconstruction algorithms. Research images will be compared to clinical images. Comparison of research images with final diagnosis will also occur. The research intervention, an ultrasound exam, has no known safety risks. The only risk to subjects is loss of confidentiality. This study is observational, not interventional, because the experimental ultrasound will be performed in all subjects and will not be used in the clinical care of patients (consequently, will not have the opportunity to affect clinical outcomes). Experimental images will be reviewed after completion of clinical care and will not be provided to the clinicians caring for the subjects. The investigators are not measuring the effect of the ultrasound examination on the subjects' outcomes.
The purpose of the Registry is to provide continuing evaluation and periodic reporting of safety and effectiveness of Medtronic market-released products. The Registry data is intended to benefit and support interests of patients, hospitals, clinicians, regulatory bodies, payers, and industry by streamlining the clinical surveillance process and facilitating leading edge performance assessment via the least burdensome approach.
The study is based on the premise that ultrasound is not commonly used in an ambulance. There are some departments that do deploy it into the field, but of those departments there is almost no data collected about its use. Currently Paramedics are not recognized by insurance companies as health care providers capable of performing ultrasound. If there were more data on the subject that may eventually change. We are hoping to prove that not only is ultrasound useful in an ambulance, but that paramedics are good at interpreting the results. We will save images, the paramedic's diagnosis and some basic information about the call. We will not save any protected health information (PHI) or any information linking the subject to the study. The data collected will be sent to a non-biased ultrasound reviewer to grade the images for the accuracy of diagnosis and the quality of the view obtained. This data will be used to formulate a report and statistics on paramedic's ability to perform ultrasound in the field.