38 Clinical Trials for Various Conditions
This study evaluates the correlation of the position of the head during sleep, independent of the position of the torso, and the severity of apnea hypopneas in obstructive sleep apnea.
Heart Failure affects 5-6 million Americans and there are about 550 thousand new cases of heart failure every year. There are approximately 3 million hospital admission for acute decompensated heart failure with hospital readmission rate of 20% at 30 days and 50% at 60 day, costing up to 20 billion dollars per year. In our previous study we have discovered that sleep disordered breathing is prevalent in 70% of patients with acute decompensated heart failure. We hypothesize that, detection and treatment of sleep disordered breathing in acute decompensated heart failure patients will reduce episodic hypoxic events during acute decompensation and may decrease hospital length of stay and reduce future readmissions.
The primary objective of this study is to evaluate the safety and tolerability of Armodafinil (CEP-10953) administered on a flexible-dosage regimen of 100 to 250 mg/day for up to 12 months to patients with excessive sleepiness associated with a current diagnosis of narcolepsy, obstructive sleep apnea/hypopnea syndrome (OSAHS)(regular users of nasal continuous positive airway pressure \[nCPAP\] therapy), or chronic shift work sleep disorder (SWSD).
The purpose of this study is to evaluate the long-term durability of the treatment and safety of the Provent device for those individuals who were enrolled in the C009 study, were diagnosed with obstructive sleep apnea-hypopnea (OSAH), and were actively using the Provent device.
Nasal Continuous Positive Airway Pressure (CPAP) is the standard therapy for obstructive sleep apnea hypopnea syndrome (OSAHS). This is most commonly administered as a single positive pressure that has been individualized for the patient to prevent obstructive respiratory events. However, the therapeutic pressure may vary by sleep stage and body position within a single night and may change over the course of several nights. One approach to dealing with this variability is the use of automatically adjusting CPAP that responds to patient breathing patterns with alterations in the delivered pressure. This study is designed to determine the effectiveness of using the energy spectrum analysis of flow signals to automatically adjust CPAP pressure and improve sleep variables. Thirty subjects who require CPAP will be recruited from the NYU sleep disorders center. Following diagnostic studies (either split night or full night) the subject will undergo a night of treatment with the Fisher and Paykel Healthcare AutoPAP. Efficacy of treatment will be evaluated based on normalization of sleep disordered breathing while treated with the AutoPAP.
The primary objectives of this study are to evaluate the safety and efficacy of VI-0521 compared to placebo in the treatment of obese adults with obstructive sleep apnea (OSA) and to assess the relative contributions of weight loss on parameters of OSA in these subjects.
The primary objective of the study is to evaluate whether armodafinil at a target dosage of 200 mg/day is more effective than placebo treatment in improving excessive sleepiness in patients with obstructive sleep apnea/hypopnea syndrome (OSAHS) who have comorbid major depressive disorder or dysthymic disorder.
The purpose of this study is to assess patient reported outcomes with armodafinil treatment in terms of improvement in sleepiness, satisfaction with treatment, impact on ability to engage in life activities (ie, daily or work and family and/or social activities), and effects on fatigue. Clinician ratings on patient response to armodafinil treatment will also be assessed.
The primary objective of the study is to evaluate the safety and tolerability of treatment with PROVIGIL in children and adolescents with excessive sleepiness (ES) associated with narcolepsy or OSAHS (obstructive sleep apnea/hypopnea), when administered for up to 12 months. Safety and tolerability will be evaluated throughout the study by means of adverse event information, clinical laboratory test results, vital signs measurements, and body weight and height measurements; quarterly physical examination findings; and 12 lead electrocardiograph (ECG) evaluations at the end of the study. In addition, the cognitive and behavioral effects of PROVIGIL will be assessed quarterly as measured by the Child Behavior Checklist for Ages 6-18 (CBCL/6-18), a brief psychiatric interview, and the Kaufman Brief Intelligence Test (KBIT 2).
The primary objectives of the study are to determine the effectiveness of PROVIGIL treatment, compared to placebo treatment, in children and adolescents with excessive sleepiness (ES) associated with obstructive sleep apnea/hypopnea syndrome (OSAHS), as assessed by: * mean sleep latency from the Multiple Sleep Latency Test (MSLT) (average of 4 naps performed at 0900, 1100, 1300, and 1500) at the last post baseline observation (week 6 or early termination) * the Clinical Global Impression of Change (CGI-C) ratings for ES, at the last post baseline observation (week 6 or early termination).
Mouth breathing is associated with increased airway resistance, pharyngeal collapsibility, and obstructive sleep apnea (OSA) severity. It is commonly believed that closing the mouth can mitigate the negative effects of mouth breathing during sleep. However, we propose that mouth breathing serves as an essential route bypassing obstruction along the nasal route (e.g., velopharynx). The present study investigates the role of mouth breathing as an essential route in some OSA patients and its association with upper airway anatomical factors. Participants underwent drug-induced sleep endoscopy (DISE) with simultaneous pneumotach airflow measurements through the nose and mouth separately. During the DISE procedure, alternating mouth closure (every other breath) cycles were performed during flow-limited breathing. We evaluated the overall effect mouth closure on inspiratory airflow, and the change in inspiratory airflow with mouth closure across three mouth-breathing quantiles. We also evaluated if velopharyngeal obstruction was associated with mouth breathing and a negative airflow response to mouth closure.
This is a prospective observational study that will collect outcome data for patients who choose to undergo transoral tongue base operations for Obstructive Sleep Apnea Hypopnea Syndrome (OSAHS)as part of their standard of care treatment. This is a data collection study only and does not provide for evaluations or treatment of OSAHS.
Primary Endpoints: •Comparison of difference in AHI at one-week in-lab polysomnography between "device on" and "device off" nights, controlling for sleep position (supine vs. non-supine) Secondary Endpoints: By polysomnography, reduction in: * AHI with device on vs. off at 3 months, controlling for sleep position * Oxygen desaturation index with device on vs. off * Arousal index with device on vs. off * Duration of snoring with device on vs. off * Epworth Sleepiness Scale Patient acceptance, in terms of: * Refusal rate at screening * Discontinuation rate during follow-up * Daily compliance rate * Device-related adverse events * Serious adverse events
Multi-center, open-label, prospective, randomized clinical trial of the aura6000(R) System for the reduction of apnea and hypopneas in adult patients with moderate to severe obstructive sleep apnea who have failed or are unwilling to use positive airway pressure treatment.
A 12 Month, Open-Label, Flexible Dosage Extension Study of the Safety and Efficacy of Armodafinil (CEP-10953) in the Treatment of Patients with Excessive Sleepiness Associated with Narcolepsy, Obstructive Sleep Apnea/Hypopnea Syndrome, or Chronic Shift Work Sleep Disorder
The primary aim is to determine whether patients with suspected OSAHS as predicted by the STOP-BANG questionnaire will have an increased length of stay (LOS) in the postanesthesia acute care unit (PACU) compared with those without suspected OSAHS. The second aim will be to determine the LOS in patients with known sleep apnea by history. This length of stay will be compared with LOS in patient with an affirmative response to the STOP-BANG questionnaire to determine if prior knowledge of diagnosed sleep apnea will be associated with a lower LOS than in patients with suspected OSA. The third aim will be to characterize the adverse clinical outcomes (respiratory, cardiovascular, and neurological) associated with suspected OSAHS in patients who respond affirmatively to the STOP-BANG questionnaire and in those patients with known OSA. These data (including number of desaturations, bradypnea, brady- or tachycardia, and use of reversal agents) will be recorded by the PACU nursing staff. Unexpected admissions to the hospital and transfers to the intensive care units will also be measured. These data will help identify the most critical determinants of length of stay.
The purpose of this study is to determine if an Autoadjusting CPAP machine is better than the regular CPAP machine in treatment of Obstructive Sleep Apnea in the postoperative setting.
The purpose of this study is to determine if two medicines (allopurinol and losartan) can influence heart and blood vessel health compared to placebo in patients with sleep apnea who are using continuous positive airway pressure (CPAP).
The purpose of the study is to compare the relative contribution of systemic inflammation vs. Obstructive Sleep Apnea (OSA) severity (as measured by Apnea Hypopnea Index) in predicting cardiovascular and metabolic aberrations associated with mild-to-moderate obstructive sleep apnea.
The investigators hypothesis is that obstructive sleep apnea (OSA) patients with a low arousal threshold may wake up too early during a respiratory event, before upper airway muscles can be activated to achieve stable ventilation. Thus, strategies to manipulate the respiratory arousal threshold could potentially improve the quality of sleep and sleep disordered breathing. Agents that raise arousal threshold are therefore likely to benefit some patients with OSA. The overall goal of this project is to determine the importance of the arousal threshold in OSA, determine which patients might benefit from a raised arousal threshold, and test this hypothesis by using pharmacological manipulation of the arousal threshold to achieve this goal.
The purpose of this research study is to collect health and physiological data using commercially available wristband fitness tracker devices (FitBit and Garmin devices) to help determine their accuracy and reliability at measuring percent of night spent in REM sleep, oxygen desaturation, and apnea hypopnea index compared with currently available methods of in-laboratory polysomnogram and home sleep testing.
The current study is a prospective blinded study to collect data regarding the performance of the WP device in detecting sleep disorders. For that purpose, the WP with finger probe and chest sensor will be worn by the subject simultaneous to PSG in a sleep study at the clinical sleep lab. A PSG system will be recording the PSG data.
The primary purpose of the study is to determine whether lemborexant increases the apnea hypopnea index (AHI) on Day 8 of treatment in adult and elderly participants (adults greater than or equal to \[\>=\] 45 to less than \[\<\] 65 years; elderly \>=65 to 90 years) with moderate to severe obstructive sleep apnea (OSA) compared with placebo, and using pulse oximetry determine whether lemborexant decreases the peripheral oxygen saturation (SpO2) during total sleep time (TST) on Day 8 of treatment in adult and elderly participants (adults \>=45 to \<65 years; elderly \>=65 to 90 years) with moderate to severe chronic obstructive pulmonary disease (COPD) compared with placebo.
Obstructive sleep apnea (OSA) is a highly prevalent disorder with adverse neurocognitive and cardio-metabolic outcomes. Continuous positive airway pressure (CPAP) is the gold standard therapeutic option to treat airway obstructions during sleep and thus, prevent its adverse cardiovascular and neurocognitive outcomes. Previous clinical trials, however, have largely failed to show a consistent impact of CPAP on these health outcomes. One of the main limitations of these trials may be the inadequate characterization of OSA and its acute physiological consequences. By characterizing OSA based on the "apnea-hypopnea index (AHI)", there is a potential risk of negative results. In this trial, the investigators intend to tackle this issue, by better characterization of OSA-related physiological consequences during sleep using physiologically driven metrics to capture the burden of OSA-related hypoxemia ("hypoxic burden"), autonomic response ("heart rate burden"), and sleep fragmentation ("arousal burden").
Central sleep apnea (CSA) is common in patients with heart failure and those using opioid analgesics. Unfortunately, effective treatment of central apnea remains elusive, pressure therapy given the modest efficiency of positive airway pressure therapy. The focus of this proposal is to identify mechanistic pathways to guide future therapeutic interventions for central sleep apnea based on the strong premise that multi-modality therapy will normalize respiration and hence mitigate adverse long-term consequences of CSA. The investigators' proposed studies will test combination therapies, including positive airway pressure (PAP) plus a pharmacological agent who have heart failure or are using opioid analgesics. The investigators anticipate that findings will inform future clinical trials to improve care and quality of life among Veterans suffering from central sleep apnea, which remains difficult to treat using existing approaches.
The study design of this research project involves orthodontic patients registered at the Harvard School of Dental Medicine who are deemed eligible to undergo orthodontic treatment and who have been provided with sufficient information to make informed consent to join the sleep study. These patients will be provided with the Medibyte sleep monitor and instructed on the proper manner in which it should be set up and worn for the one night study period. This process will be carried out twice throughout the course of the study, once before any orthodontic appliance has been cemented and once after the required amount of tooth movement has been attained with the orthodontic appliance still in place. The de-identified data from the Medibyte monitor will be downloaded using the Braebon software and analyzed.
Test the effect of added a single-use Varnum mouthpiece on pharyngeal collapsibility and obstructive sleep apnea (OSA) severity in patients who identify themselves as mouth breathers. Research indicates that nasal breathing not only may improve sleep apnea but it also increases circulation, blood oxygen, and carbon dioxide levels, slows the breathing rate, and improves overall lung volumes. Thus, the investigators will test whether a single-use Varnum mouthpiece can improve pharyngeal collapsibility and OSA severity in mouth breathers.
The addition of intranasal oxymetazoline for two weeks to already instituted optimal doses of intranasal fluticasone propionate will decrease the total number of obstructive apneas and hypopneas per hour of sleep in subjects with perennial allergic or non-allergic rhinitis and mild obstructive sleep apnea who have persistent nasal congestion despite maximum doses of NGCS.
The purpose of this study is to evaluate the accuracy of Somnarus diagnostic technology for diagnosis of sleep apnea in human subjects. This includes evaluation of Somnarus technology in Obstructive Sleep Apnea (OSA) and Central Sleep Apnea (CSA), including Cheyne - Stokes respiration (CSR).
In Obstructive sleep apnea (OSA), the upper airway closes over and over again during sleep. This leads to disrupted sleep (waking up during the night), daytime sleepiness, and an increased risk for developing high blood pressure. Currently, the best treatment for obstructive sleep apnea is sleeping with a mask that continuously blows air into the nose (i.e. Continuous positive airway pressure \[CPAP\] treatment). While CPAP treatment stops the upper airway from closing in most people, many people have difficulty sleeping with the mask in place and therefore do not use the CPAP treatment. This research study is being conducted to learn whether using a sedative will improve OSA severity by altering some of the traits that are responsible for the disorder.