5 Clinical Trials for Various Conditions
The purpose of this study is to compare changes in RV structure and function, biomarkers, and patient reported outcomes between TOF patients randomized to an ARNI vs placebo.
Cardiac surgery induces a measurable stress response in patients which leads to increased morbidity and mortality post-operatively. Through clinical observation, anesthesiologists have determined that varying the combinations of anesthesia drugs used during surgery and just after reduces the stress response, and by extension, morbidity and mortality. However, only a few studies have explored this phenomenon scientifically.
This real-world, international registry aims to evaluate the current experience with sodium-glucose cotransporter 2 inhibitors (SGLT2i) in adult congenital heart disease (ACHD) patients by investigating the prescription patterns, safety, tolerability, and potential beneficial effects on heart failure-related outcomes.
At Children's Healthcare of Atlanta at Egleston, it is standard of care to do a cardiac MRI on patients with the diagnosis of Tetralogy of Fallot and Aortic Coarctation to evaluate heart function. We propose to do a retrospective chart review of patient data along with their MRI data to analyze ventricular function and cavity volumes pre-Tetralogy of Fallot repair, post-Tetralogy of Fallot repair (pre-valve repair/replacement) and post-valve repair/replacement in order to assess the efficacy and optimal timing of valve replacement.
Assessment of Right Ventricular Volume using the VentriPoint Medical system in patients with Tetralogy of Fallot following repair; a comparison study to cMRI. The objective of this study is: To evaluate the accuracy of the VentriPoint Medical System to calculate right ventricular volumes in patients with Tetralogy of Fallot following surgical repair. Secondary objectives are: To validate Inter and Intra observer variability at 3 clinical sites. The analyses will be the same for EDV and ESV. For either right ventricular volume, the primary effectiveness measure is the % difference between VMS and cMRI results, i.e. (VMS-cMRI)\*100%/average of VMS and cMRI results. There will be two null hypotheses for the primary analysis: H0+: true mean % difference \> 10% and H0-: true mean % difference \< -10% The observed mean % difference will be presented with 95% confidence intervals. The VMS right ventricular volume estimates will be regarded as equivalent to cMRI estimates if both H0+ and H0- are rejected at a 1-sided 0.025 level by a paired t test for both EDV and ESV. Since H0+ and H0- cannot both be true, the total type I error rate for each measure is 0.025 and the overall type I error rate for both EDV and ESV is 0.05.