Non-Invasive Cardiac Output Monitor (NICOM) for Goal-directed Fluid Resuscitation for Inpatients With Hypotension and/or Septic Shock

Description

The Non-Invasive Cardiac Output Monitor (NICOM) is a non-invasive monitor capable of measuring cardiac output (CO) and cardiac index (CI), and stroke volume (SV) and stroke volume index (SVI) based on heart rate. Conceptually NICOM is a technology that utilizes a dynamic response characteristic in assessing the need for fluid administration, whereby SVI is measured before and after a fluid challenge with more fluid given only if SVI increases significantly with administered fluid. Dynamic response technologies are intended to replace older, "static" measures such as central venous pressure (CVP) and pulmonary capillary wedge pressures (PCWP) which are single point measurements utilized to assess the need to administer fluid. The aim is to pilot and evaluate the effectiveness of using The Non-Invasive Cardiac Output Monitor (NICOM) technology for goal-directed fluid resuscitation in adult inpatients with sepsis associated acute hypotension and/or evidence of septic shock (Lactate \>= 4.0).

Conditions

Sepsis, Hypotension, Septic Shock

Study Overview

Study Details

Study overview

The Non-Invasive Cardiac Output Monitor (NICOM) is a non-invasive monitor capable of measuring cardiac output (CO) and cardiac index (CI), and stroke volume (SV) and stroke volume index (SVI) based on heart rate. Conceptually NICOM is a technology that utilizes a dynamic response characteristic in assessing the need for fluid administration, whereby SVI is measured before and after a fluid challenge with more fluid given only if SVI increases significantly with administered fluid. Dynamic response technologies are intended to replace older, "static" measures such as central venous pressure (CVP) and pulmonary capillary wedge pressures (PCWP) which are single point measurements utilized to assess the need to administer fluid. The aim is to pilot and evaluate the effectiveness of using The Non-Invasive Cardiac Output Monitor (NICOM) technology for goal-directed fluid resuscitation in adult inpatients with sepsis associated acute hypotension and/or evidence of septic shock (Lactate \>= 4.0).

Pilot Evaluation Using The Non-Invasive Cardiac Output Monitor (NICOM) for Goal-directed Fluid Resuscitation for Inpatients With Hypotension and/or Septic Shock

Non-Invasive Cardiac Output Monitor (NICOM) for Goal-directed Fluid Resuscitation for Inpatients With Hypotension and/or Septic Shock

Condition
Sepsis
Intervention / Treatment

-

Contacts and Locations

Minneapolis

University of Minnesota, Minneapolis, Minnesota, United States, 55455

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

For general information about clinical research, read Learn About Studies.

Eligibility Criteria

  • * All adult patients \> 18 years of age
  • * inpatients for \>/= 6 hours
  • * meeting criteria for sepsis as defined by hypotension related to sepsis (MAP \< 65 or SBP \< 90) or evidence of septic shock (Lactate ≥ 4.0).
  • * Patients who die within 24 hours of hospital admission
  • * patients documented as "comfort cares" or enrolled in "general inpatient hospice" during the first 72 hours of hospitalization.
  • * opted out of having their medical information used in research, as noted in the EHR.

Ages Eligible for Study

18 Years to

Sexes Eligible for Study

ALL

Accepts Healthy Volunteers

No

Collaborators and Investigators

University of Minnesota,

Jeffrey Dichter, MD, PRINCIPAL_INVESTIGATOR, University of Minnesota

Study Record Dates

2025-11-30