Smartphone Twelve-Lead ECG Utility In ST-Elevation Myocardial Infarction II

Description

AliveCor (www.alivecor.com) has developed several electrocardiogram (ECG) devices that interface with iOS and Android smartphones and tablets via various Kardia apps. The current Kardia family of devices can measure single lead and six limb-lead ECGs, depending on the device. KardiaMobile, KardiaMobile 6L, and KardiaMobile Card have FDA clearance for ECG rhythm recording. A modified single-lead Kardia smartphone 12-lead ECG was previously validated in the multicenter ST LEUIS study for the diagnosis of ST-Segment Elevation Myocardial Infarction (STEMI) and Non-ST-Elevation Myocardial Infarction (NSTEMI). Recently, AliveCor developed a new device: AliveCor (AC) 12-lead (12L) ECG System to record simultaneously 4 leads of ECG and then generate complete 12-lead ECGs. A previous protocol at the University of Oklahoma involved 200 subjects with early prototypes of the AC 12L device with the specific aim to validate that it accurately generated 12-lead ECGs as compared to simultaneously acquired FDA-cleared 12-lead ECGs. The prototype version of the AliveCor 12L ECG System simultaneously measured four channels of ECG (leads I, II, V2, V4), calculated the remaining limb leads as is standard for 12-lead ECGs (Leads III, aVR, aVL, aVF) and synthesized the remaining 4 precordial ECG leads (V1, V3, V5, V6). This protocol will serve to validate the production version of the system against standard 12-Lead ECGs for the diagnosis of STEMI and NSTEMI in patients admitted to the Emergency Department or directly to the Cardiac Cath Lab for the evaluation of chest pain. It is anticipated that the waveforms for each of the 12 leads from the AC 12L ECG System will be highly correlated with the corresponding leads from the comparator commercially available 12-lead ECG devices used at participating sites. The purpose of this study is to clinically validate that the four-channel AC 12L ECG device can enable the diagnosis of STEMI and NSTEMI in a non-inferior manner to existing 12-lead ECG devices.

Conditions

Myocardial Infarction, Ischemia, Myocardial Ischemia, Heart Diseases, Cardiovascular Diseases, Vascular Diseases, Heart Attack, Heart Failure

Study Overview

Study Details

Study overview

AliveCor (www.alivecor.com) has developed several electrocardiogram (ECG) devices that interface with iOS and Android smartphones and tablets via various Kardia apps. The current Kardia family of devices can measure single lead and six limb-lead ECGs, depending on the device. KardiaMobile, KardiaMobile 6L, and KardiaMobile Card have FDA clearance for ECG rhythm recording. A modified single-lead Kardia smartphone 12-lead ECG was previously validated in the multicenter ST LEUIS study for the diagnosis of ST-Segment Elevation Myocardial Infarction (STEMI) and Non-ST-Elevation Myocardial Infarction (NSTEMI). Recently, AliveCor developed a new device: AliveCor (AC) 12-lead (12L) ECG System to record simultaneously 4 leads of ECG and then generate complete 12-lead ECGs. A previous protocol at the University of Oklahoma involved 200 subjects with early prototypes of the AC 12L device with the specific aim to validate that it accurately generated 12-lead ECGs as compared to simultaneously acquired FDA-cleared 12-lead ECGs. The prototype version of the AliveCor 12L ECG System simultaneously measured four channels of ECG (leads I, II, V2, V4), calculated the remaining limb leads as is standard for 12-lead ECGs (Leads III, aVR, aVL, aVF) and synthesized the remaining 4 precordial ECG leads (V1, V3, V5, V6). This protocol will serve to validate the production version of the system against standard 12-Lead ECGs for the diagnosis of STEMI and NSTEMI in patients admitted to the Emergency Department or directly to the Cardiac Cath Lab for the evaluation of chest pain. It is anticipated that the waveforms for each of the 12 leads from the AC 12L ECG System will be highly correlated with the corresponding leads from the comparator commercially available 12-lead ECG devices used at participating sites. The purpose of this study is to clinically validate that the four-channel AC 12L ECG device can enable the diagnosis of STEMI and NSTEMI in a non-inferior manner to existing 12-lead ECG devices.

Smartphone Twelve-Lead ECG Utility In ST-Elevation Myocardial Infarction II (STLEUISII)

Smartphone Twelve-Lead ECG Utility In ST-Elevation Myocardial Infarction II

Condition
Myocardial Infarction
Intervention / Treatment

-

Contacts and Locations

Rochester

Mayo Clinic, Rochester, Minnesota, United States, 55905

Murray

Intermountain Health, Murray, Utah, United States, 84107

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

For general information about clinical research, read Learn About Studies.

Eligibility Criteria

  • * Male or female \> 18 years of age.
  • * Ability to understand and sign a written informed consent form, which must be obtained prior to initiation of any study procedures.
  • * Symptoms of chest pain upon presentation at the Emergency Department of the participating institution.
  • * Inability or refusal of the patient and/or the patient's legally acceptable representative to provide written informed consent for any reason.
  • * Other conditions that in the opinion of the Lead Investigator may increase risk to the subject and/or compromise the quality of the clinical trial.

Ages Eligible for Study

18 Years to

Sexes Eligible for Study

ALL

Accepts Healthy Volunteers

Yes

Collaborators and Investigators

AliveCor,

Study Record Dates

2024-12