The SEQUENCE Trial: Evaluating Diagnostic Yield of Robotic-assisted Bronchoscopy When Staging EBUS is Performed First or Second in the Same Procedure

Description

Robotic-assisted bronchoscopy (RaB) has afforded proceduralists the ability to accurately reach the periphery of the lung for biopsy of pulmonary nodules1. This has paved the way for patients to undergo both biopsy of a peripheral nodule and a staging linear endobronchial ultrasound (EBUS) in the same anesthesia event, promoting quicker throughput from discovery of a lesion to guideline-adherent treatment2. Further, introduction and mainstream utilization of cone-beam CT (CBCT) has provided the bronchoscopist the ability to refine needle position with tool-in-lesion confirmation3. While there are no randomized clinical trials promoting efficacy of RaB and CBCT in comparison with other bronchoscopic methods, in single center retrospective studies, diagnostic yield has consistently proven to be in the 70-85% range, superior to prior technologies4-6. One of the limitations of utilization of RaB and CBCT is the detrimental effect that atelectasis plays in the bronchoscopy procedure. This can lead to false positive radial EBUS (rEBUS) signals and non-diagnostic procedures7. This incidence of atelectasis has been evaluated prospectively, using a protocol featuring 8-10 cmH2O of PEEP and limiting hyperoxia8, and results suggest this ventilator strategy does an adequate job preventing intraprocedural lung collapse. However, this study only evaluated incidence of atelectasis and did not elaborate on its impact on diagnostic yield. Further unknown is the optimal sequence of performance of RaB and a staging linear EBUS in patients with a radiographically normal mediastinum. Starting with either the RaB or Linear EBUS both have their pros and cons. The benefit to performance of a linear EBUS first is the potential to obviate the need for peripheral nodule biopsy by obtaining rapid, on-site pathologic feedback of occult nodal disease, reducing some of the risk of the procedure (i.e. bleeding and pneumothorax).6 Conversely, the pitfalls to performing linear EBUS first is the possible contribution of atelectasis resultant of the increased time from intubation to peripheral nodule biopsy, blood in the airway causing bronchospasm, and resorption atelectasis from hyperoxia9. There are no prospective data evaluating this in a randomized fashion, but one Monte Carlo simulation (with assumption of diagnostic yield from navigational bronchoscopy of 70% when performed first and 60% when performed second) suggested a higher diagnostic yield and less need for repeat procedure in the navigation first group, despite a 10% assumption of occult nodal disease10. As outlined in the specific aims above, the overarching goals of this study are to assess in a multicenter, randomized clinical trial performed by members of the Interventional Pulmonary Outcomes Group (IPOG), whether sequence of staging EBUS plays a role in diagnostic yield, incidence of atelectasis, and safety outcomes in patients undergoing RaB.

Conditions

Pulmonary Nodules

Study Overview

Study Details

Study overview

Robotic-assisted bronchoscopy (RaB) has afforded proceduralists the ability to accurately reach the periphery of the lung for biopsy of pulmonary nodules1. This has paved the way for patients to undergo both biopsy of a peripheral nodule and a staging linear endobronchial ultrasound (EBUS) in the same anesthesia event, promoting quicker throughput from discovery of a lesion to guideline-adherent treatment2. Further, introduction and mainstream utilization of cone-beam CT (CBCT) has provided the bronchoscopist the ability to refine needle position with tool-in-lesion confirmation3. While there are no randomized clinical trials promoting efficacy of RaB and CBCT in comparison with other bronchoscopic methods, in single center retrospective studies, diagnostic yield has consistently proven to be in the 70-85% range, superior to prior technologies4-6. One of the limitations of utilization of RaB and CBCT is the detrimental effect that atelectasis plays in the bronchoscopy procedure. This can lead to false positive radial EBUS (rEBUS) signals and non-diagnostic procedures7. This incidence of atelectasis has been evaluated prospectively, using a protocol featuring 8-10 cmH2O of PEEP and limiting hyperoxia8, and results suggest this ventilator strategy does an adequate job preventing intraprocedural lung collapse. However, this study only evaluated incidence of atelectasis and did not elaborate on its impact on diagnostic yield. Further unknown is the optimal sequence of performance of RaB and a staging linear EBUS in patients with a radiographically normal mediastinum. Starting with either the RaB or Linear EBUS both have their pros and cons. The benefit to performance of a linear EBUS first is the potential to obviate the need for peripheral nodule biopsy by obtaining rapid, on-site pathologic feedback of occult nodal disease, reducing some of the risk of the procedure (i.e. bleeding and pneumothorax).6 Conversely, the pitfalls to performing linear EBUS first is the possible contribution of atelectasis resultant of the increased time from intubation to peripheral nodule biopsy, blood in the airway causing bronchospasm, and resorption atelectasis from hyperoxia9. There are no prospective data evaluating this in a randomized fashion, but one Monte Carlo simulation (with assumption of diagnostic yield from navigational bronchoscopy of 70% when performed first and 60% when performed second) suggested a higher diagnostic yield and less need for repeat procedure in the navigation first group, despite a 10% assumption of occult nodal disease10. As outlined in the specific aims above, the overarching goals of this study are to assess in a multicenter, randomized clinical trial performed by members of the Interventional Pulmonary Outcomes Group (IPOG), whether sequence of staging EBUS plays a role in diagnostic yield, incidence of atelectasis, and safety outcomes in patients undergoing RaB.

The SEQUENCE Trial: Should Endobronchial Ultrasound QUeue bEfore or eNsuing to robotiC-assisted Bronchoscopy for pEripheral Pulmonary Nodule Biopsy? A Patient Randomized Control Trial Assessing the Effect of the Ordering of Robotic-assisted Bronchoscopy and Linear EBUS During the Same Anesthesia Event on Diagnostic Yield From Peripheral Pulmonary Nodule Biopsy

The SEQUENCE Trial: Evaluating Diagnostic Yield of Robotic-assisted Bronchoscopy When Staging EBUS is Performed First or Second in the Same Procedure

Condition
Pulmonary Nodules
Intervention / Treatment

-

Contacts and Locations

Chicago

Northwestern University, Chicago, Illinois, United States, 60611

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

For general information about clinical research, read Learn About Studies.

Eligibility Criteria

  • * Peripheral Pulmonary Nodule undergoing a robotic-assisted bronchoscopy
  • * lymph nodes that are enlarged or PET avid on CT prior to procedure

Ages Eligible for Study

18 Years to

Sexes Eligible for Study

ALL

Accepts Healthy Volunteers

Yes

Collaborators and Investigators

Northwestern University,

Study Record Dates

2027-04-01