45 Clinical Trials for Various Conditions
Prospective, multi-center, randomized, single blind, controlled, noninferiority clinical trial. Subjects with previous bare-metal stent (BMS) or DES and qualifying evidence for ISR will be screened per the protocol inclusion and exclusion criteria. Eligible subjects will be randomized 1:1 to treatment with either the SELUTION SLR™ 014 DEB or SOC to include contemporary DES (zotarolimus-eluting stents \[ZES\] and everolimus-eluting stents \[EES\] only) or BA. A maximum of 20% of patients randomized to SOC will be treated with BA. The primary endpoint will be Target Lesion Failure (TLF) at 12-months in the SOC group vs. the SELUTION SLR™ 014 DEB in all patients.
In this replication study at the Cleveland Clinic, we seek to collaborate to validate findings of the CardioGene Study in an independent cohort of patients who have undergone bare metallic stenting.
The objective of this study is to evaluate the safety and effectiveness of the TAXUS Express2 Paclitaxel-Eluting Coronary Stent System as compared to brachytherapy in patients experiencing in-stent restenosis.
STAR is a minimal-risk pragmatic clinical trial of patients admitted for a CTO-PCI procedure. The overall objective of the STAR Study is to address the current gaps in knowledge regarding use of STAR during CTO-PCI, as a prospective, multi-center study of 150 participants with randomization of timing of staged PCI. Five sites will be selected to participate in STAR from a national network of highly experienced CTO-PCI centers across the United States.
Abbott Vascular (AV) obtained marketing approval for the XIENCE PRIME Everolimus Eluting Coronary Stent System (XIENCE PRIME EECSS) in China from the China Food and Drug Administration (CFDA) on August 10th, 2011. This prospective, observational, open-label, multi-center, single-arm, post-approval study is designed to evaluate the continued safety and effectiveness of the XIENCE PRIME EECSS in a cohort of real-world patients receiving the XIENCE PRIME EECSS during commercial use in real-world settings in China. This study has no primary outcome measure. All observations are of equal weight.
This is a prospective, observational, single-arm, open-label, multicenter, postapproval registry study in China. The purpose of this study is to: * Evaluate the continued safety and effectiveness of the XIENCE V EECSS in a cohort of real-world patients receiving the XIENCE V EECSS during commercial use * Evaluate patient compliance to dual antiplatelet therapy (DAPT)
The purpose of the Universal Registry is to assess the proportion and reasons for which subjects with angiographically significant ULMCA disease requiring revascularization during the time course of this study are not randomized; to compare the baseline characteristics of subjects; and to assess the variability in randomization eligibility and treatment patterns.
To establish the safety and efficacy of the commercially approved XIENCE Family Stent System (inclusive of XIENCE PRIME, XIENCE V, XIENCE Xpedition and XIENCE PRO \[for use outside the United States \[OUS\] only\]) in subjects with unprotected left main coronary artery disease by comparing to coronary artery bypass graft surgery.
XIENCE V USA is a prospective, multi-center, multi-cohort post-approval study. The objectives of this study are * To evaluate XIENCE V EECSS continued safety and effectiveness during commercial use in real world settings, and * To support the Food and Drug Administration (FDA) dual antiplatelet therapy (DAPT) initiative. This initiative is designed to evaluate the composite of all death, myocardial infarction (MI) and stroke (MACCE) and the survival of patients that are free from Academic Research Consortium (ARC) definite or probable stent thrombosis (ST) and that have been treated with drug eluting stents (DES) and extended dual antiplatelet therapy.
XIENCE V USA is a prospective, multi-center, multi-cohort postapproval study. The objectives of this study are * To evaluate XIENCE V EECSS continued safety and effectiveness during commercial use in real world settings, and * To support the Food and Drug Administration (FDA) dual antiplatelet therapy (DAPT) initiative. This initiative is designed to evaluate the composite of all death, myocardial infarction (MI) and stroke (MACCE) and the survival of patients that are free from Academic Research Consortium (ARC) definite or probable stent thrombosis (ST) and that have been treated with drug eluting stents (DES) and extended dual antiplatelet therapy.
To evaluate the safety and effectiveness of the XIENCE PRIME and XIENCE PRIME Long Lesion (LL) Everolimus Eluting Coronary Stent System (EECSS) in improving coronary luminal diameter in subjects with symptomatic heart disease due to a maximum of two de novo native coronary artery lesions, each in a different epicardial vessel.
This study is a prospective, non-randomized, open-label registry of consecutive patients with CAD treated by stent-assisted PCI using at least one CypherTM stent. Up to 1000 pts will be included in the registry. The registry is conducted for the evaluation of the impact of CypherTM Sirolimus-eluting stent implantation in the "real world" of interventional cardiology. Informed consent will be obtained from patients meeting the inclusion criteria before the initiation of any study specific procedures. Consecutive patients treated with the use of the CypherTM stent will be included in the registry. Baseline and post-procedure blood samples will be used to perform platelet function analysis using the Accumetrics Ultegra RPFA (Rapid Platelet Function Assay). All patients will be followed from enrollment through the hospital discharge for any clinically significant event (death, myocardial infarction, TLR, TVR, major or minor bleeding). A follow-up telephone assessment of death, myocardial infarction, revascularization, and medical treatment will be conducted by experienced research personnel at 30 days, 6 months, 1 year and at least 2 years. All site reported deaths, myocardial infarctions and revascularizations will be adjudicated by an independent Clinical Events Committee for all 1000 patients enrolled in the trial. An interim analysis of the first 750 patients will be conducted and data forwarded to FDA.
This study is a prospective study of patients treated at Scripps Clinic with intracoronary brachytherapy for recurrent restenosis within drug eluting stents.
Males and females aged 18-80 years who present with ACS (unstable angina and non ST-elevation MI) defined as one or more episodes of angina lasting at least 5 minutes in the last 24 hours before admission and greater than 0.05 mV of presumed new ST-segment depression in at least 2 contiguous ECG leads OR, angina and per confirmatory angiogram, has been scheduled for percutaneous coronary angioplasty. The primary objective of this study is to evaluate the safety of Serp-1 injection when administered in 3 daily doses to patients undergoing conventional therapy for Acute Coronary Syndrome (ACS) requiring early intervention.
PROSPECT is a multi-center prospective registry of Acute Coronary Syndromes (ACS) patients with single or double vessel coronary artery disease. Approximately 700 patients with ACS will be enrolled into the study at sites in the United States and European Union.
The purpose of this clinical research study is determine if patients with diabetes that have undergone previous opening of a heart blockage may have a blockage that is not causing any symptoms that may be detected by imaging with Cardiolite.
The purpose of this study is to demonstrate the safety and efficacy of the ZoMaxx drug-eluting stent in patients with blockage of native coronary arteries. The study is designed to demonstrate non-inferiority to the TAXUS Express2 Paclitaxel-Eluting Stent that has proven superior to bare metal stents and is a recognized standard of care.
This research study is intended to evaluate the safety and effectiveness of 3 different doses of BO-653, an investigational inhibitor of LDL cholesterol oxidation, when given orally twice a day compared to placebo (an inactive substance) in preventing restenosis (closure of vessel) within six months after stent implantation. Patients must be enrolled into this study within 24 hours after the stenting procedure. Additionally, over a 1- to 9-month post-stent period, the study will compare the safety and effectiveness of BO-653 versus placebo for measures of coronary artery vessel size by quantitative coronary angiography, major adverse cardiac events, and effects on the oxidative status of plasma lipids and other plasma components.
Despite the benefit of drug-eluting stents (DES) to reduce the need for repeat revascularization procedures, concerns regarding late stent thrombosis (ST) have led to recent guidelines advocating extended prescription of dual antiplatelet therapy (DAPT) with aspirin and a thienopyridine (clopidogrel or ticlopidine\]) beyond that described in the product labeling. Specifically, an advisory has recommended at least 1 year DAPT following treatment with DES in patients without contraindications. However, this recommendation was largely empiric and not based on any trial showing reductions in ST with long-term DAPT, nor are potential safety differences between DES considered. Further, no study has examined the balance in potential efficacy with long-term DAPT relative to an increased bleeding risk. A consistency across clinical trials involving the Endeavor DES has been very low rates of late myocardial infarction, cardiac death and ST. Unlike other DES, recent studies indicate that the Endeavor stent may permit more rapid and complete healing over stent struts in addition to restoring normal blood vessel function. Further, in patients treated with the Endeavor stent, long-term safety outcomes are similar through 3 years follow-up irrespective of whether patients were adherent to DAPT for durations of ≤ 6 months, 12 months or 24 months. In this study, long-term safety and effectiveness will be examined for patients treated with the Endeavor stent and assigned to DAPT for reduced duration of 6 months. If the study demonstrates safety and efficacy, it could influence treatment guidelines in favor of an abbreviated duration of DAPT for patients treated with the Endeavor stent. This would mean that should a bleeding complication or need or surgery arise less than 12 months post-PCI, patients treated with the Endeavor stent could stop DAPT after 6 months with reasonable estimate of safety. Furthermore, it is possible that patients who are currently denied DES due to known need for elective surgery could be treated with the Endeavor stent in cases where surgery can be temporarily delayed. Finally, it could be an additional option for patients who forgo treatment with DES in favor of bare metal stent (BMS) out of fear of possible bleeding with long-term DAPT. Finally, it is recognized that not all patients respond the same way to anti-platelet therapy. Recent studies have indicated that inherited genetic variations in the way the body metabolizes anti-platelet medications may be important determinants of responsiveness to thienopyridine therapy, and that such differences may also confer a higher likelihood of adverse outcome. Patients agreeing to the additional genetic sub-study will have a DNA sample taken at baseline to test for the presence of such genes related to antiplatelet therapy metabolism and effectiveness. The results of these tests could help the medical community to better understand individual variation in response to anti-platelet therapy and the role that genetics may play in determining the response. It is possible that the information gained could help physicians tailor DAPT on a patient by patient basis.
The specific aim of the SOS-Xience V study is to examine the 12-month incidence of binary angiographic in-stent restenosis after implantation of the Xience V stent in aortocoronary saphenous vein bypass graft lesions.
The study will evaluate the long-term safety and efficacy of intravascular beta radiation therapy to treat coronary in-stent restenosis using the Beta-Cath(TM) 3.5F System; data will be collected retrospectively on patients treated with the Beta-Cath™ 3.5F System in routine clinical practice following FDA pre-market approval of the System. Outcomes will be reported up to 5 years following treatment.
XIENCE V USA is a prospective, multi-center, multi-cohort post-approval study. The objectives of this study are * To evaluate XIENCE V EECSS continued safety and effectiveness during commercial use in real world settings, and * To support the Food and Drug Administration (FDA) dual antiplatelet therapy (DAPT) initiative. This initiative is designed to evaluate the composite of all death, myocardial infarction (MI) and stroke (MACCE) and the survival of patients that are free from Academic Research Consortium (ARC) definite or probable stent thrombosis (ST) and that have been treated with drug eluting stents (DES) and extended dual antiplatelet therapy.
The purpose of the SPIRIT IV Clinical Trial is to continue to evaluate the safety and efficacy of the XIENCE V® Everolimus Eluting Coronary Stent System (XIENCE V®). The XIENCE V® arm will be compared to an active control, represented by the FDA-approved TAXUS® EXPRESS2™ Paclitaxel-Eluting Coronary Stent System (TAXUS®), commercially available from Boston Scientific. TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent System is manufactured by Boston Scientific.
The main purpose of this study is to determine whether implantation of a paclitaxel-eluting stent (Taxus™) in saphenous vein graft lesions will reduce the incidence of in-stent restenosis after 12 months when compared to a similar bare metal stent.
To define the long-term incidence and frequency of ISR follow DES implantation. Compare the clinical presentation, treatment and intervention success among de novo coronary artery stenosis and DES ISR. Compare short- and long-term outcomes of de novo coronary artery stenosis and DES ISR, assessed by incidence of mortality, MACE, MI, and TLR/TVR at index hospitalization, 30 days, 6 months, 1 year, 3 years, and 5 years, if available.
This study aims to test the hypothesis that plaque composition differs within a stent between bare metal stents and drug eluting stents (DES). It is possible that a difference in plaque composition seen within a stent may be contributory to the late thrombotic events seen more frequently with DES.
The AV-MDR is a prospective, non-randomized, open-label, multi-center registry. The purpose of the AV-MDR study is to proactively collect and evaluate clinical data on the usage of the devices in scope within their intended use with the aim of confirming safety and performance throughout their expected lifetime, ensuring the continued acceptability of identified risks, detecting emerging risks on the basis of factual evidence, ensuring the continued acceptability of the benefit-risk ratio, and identifying possible systematic misuse or off-label usage such that the intended use can be verified as appropriate.
BACKGROUD: Percutaneous coronary intervention (PCI) is increasingly used to treat unprotected left main coronary artery stenosis. Protected LM PCI is considered standard of care in most centers. OCT allows for precise determination of stent placement, stent expansion and apposition. The pattern of vessel healing can be very precisely studied if immediate post-stent implantation OCT/IVUS data is compared to the 6-month post-PCI interval. While OCT cannot be optimally used for ostial lesion imaging, IVUS can be used to image ostial lesions/stent placement. Optimal and consistent vessel healing is particularly important in LM PCI where stent thrombosis is a potential complication with serious adverse outcome. HYPOTHESIS: Due to the absorption of the polymer of the Boston Scientific Synergy Stent over time, early strut coverage patterns and timeline may be different than previously observed in DES and BMS stents in LM PCI. Late acquired stent malapposition (LASM) is expected to differ from previous observations with traditional DES/BMS. Stent coverage in LM PCI will be studied with OCT or IVUS at six and 12 months and compared to OCT or IVUS at the time of stent implantation. OCT/IVUS data will be analyzed in a core lab (CRF) and correlated with clinical outcomes at 6 and 12 months.
This study is divided into 5 arms: 1. Randomized Clinical Trial (RCT): Prospective, randomized, active-controlled, single blind, parallel two-arm multi-center clinical trial in the United States (US) comparing XIENCE V® Everolimus Eluting Coronary Stent System (CSS) (2.5, 3.0, 3.5 mm diameter stents) to the Food and Drug Administration (FDA) approved commercially available active control TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent (TAXUS® EXPRESS2™ PECS) System 2. US 2.25 mm non-randomized arm using 2.25 mm diameter XIENCE V® Everolimus Eluting CSS 3. US 4.0 mm non-randomized arm using 4.0 mm diameter XIENCE V® Everolimus Eluting CSS 4. US 38 mm non-randomized arm using 38 mm in length XIENCE V® Everolimus Eluting CSS 5. Japanese non-randomized arm using XIENCE V® Everolimus Eluting CSS (2.5, 3.0, 3.5, 4.0 mm diameter stents) in Japan The TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent System is Manufactured by Boston Scientific.
The ABSORB III PK sub-study is a prospective, open-label, non-blinded study enrolling approximately 12 subjects in up to 5 US sites. ABSORB III PK sub-study is a part of ABSORB III RCT (NCT01751906). The objective is to determine the pharmacokinetics of everolimus delivered by the Absorb BVS in a separate and non-randomized cohort of subjects who only receive Absorb BVS with a maximum of two de novo native coronary artery lesions after implantation of the Absorb BVS. Note: The ABSORB III PK subjects will not contribute to the determination of the ABSORB III RCT primary endpoint.