The Oxygen Reserve Index (ORi) is a reference that could help clinicians with their assessments of normoxic and hyperoxic states by scaling the measured absorption information between 0.00 and 1.00. An ORi of 0.00 corresponds to partial pressure of oxygen (PaO2) values of 100 mmHg and below and an ORi of 1.00 corresponds to PaO2 values of 200 mmHg and above. This is clinical study designed to evaluate the clinical utility of the Oxygen Reserve Index (ORI) as an early warning for arterial hemoglobin desaturation during the induction of general anesthesia and tracheal intubation in obese patients undergoing elective surgical procedures.
This study aims to test the accuracy of the Perin Health Patch (PHP), a non-invasive, chest-worn device that measures blood oxygen levels, by comparing its readings to a standard pulse oximeter device. The PHP device uses light sensors to measure blood oxygen saturation (SpO2), similar to how standard pulse oximeters work, and could allow for continuous remote monitoring at home. Participants in this study will breathe low-oxygen air through a mask to simulate different oxygen levels in a controlled environment. The goal is to see if the PHP device can accurately measure blood oxygen levels under different conditions and meet safety standards set by the FDA and international guidelines.
The objective is to validate the performance of SpO2 measurement of the TipTraQ by comparing it with measurement from an artery blood sample of a healthy volunteer in a controlled desaturation study. The overall framework of the validation process followed Annex EE.2 of ISO 80601-2-61:2019.
Sleep apnea has become exceedingly recognized in children. The primary treatment for sleep apnea in children is surgery in the form of adenotonsillectomy. The majority of children that undergo adenotonsillectomy are discharged following their immediate recovery in the post anesthesia care unit.
Validation study to compare the accuracy of non-invasive Philips SpO2 sensors in detecting blood oxygen levels compared to invasive methods requiring a blood draw and lab analysis.
This study is designed to compare the accuracy of a noninvasive measurement of oxygen saturation compared to reference values obtained by a laboratory blood gas analyzer. Arterial blood samples will be collected from healthy adult subjects while undergoing a desaturation procedure wherein the concentration of oxygen inhaled is slowly reduced. The subject will then be returned to breathing room air.
This study is designed to evaluate the trending accuracy of a noninvasive regional oximetry measurement of somatic oxygen saturation. One investigational sensor (INVSENSOR00038) will be placed on the somatic site of the volunteer. The values obtained by the test sensor will be compared to the reference value obtained from an FDA-cleared sensor placed on the somatic site on the contralateral side. Data will be collected from healthy adult subjects while undergoing a desaturation procedure wherein the concentration of oxygen inhaled is slowly reduced until the subject's oxygen saturation is approximately 70%. The subject will then be returned to inhaling room air.
This study is designed to evaluate the trending accuracy of a noninvasive regional oximetry measurement of somatic oxygen saturation. One investigational sensor (INVSENSOR00037) will be placed on the somatic site of the volunteer. The values obtained by the test sensor will be compared to the reference value obtained from an FDA-cleared sensor placed on the somatic site on the contralateral side.
This study is designed to evaluate the trending accuracy of a noninvasive regional oximetry measurement of somatic oxygen saturation. One investigational sensor (INVSENSOR00036) will be placed on the somatic site of the volunteer. The values obtained by the test sensor will be compared to the reference value obtained from an FDA-cleared sensor placed on the somatic site on the contralateral side.
The study compares the effect of thigh high compression stockings on cerebral desaturation events in patients undergoing shoulder arthroscopy in the beach chair position with a BMI greater than or equal to 30.
As part of routine care for SCD, some people are found to have low oxygen levels (≤ 88%) while sleeping, at rest, or with exercise. Testing is done with a small portable device positioned on the finger that measures oxygen levels during sleep, at rest, or following exercise. The investigators start oxygen treatment for people with low levels of oxygen. As a part of this study, the investigators will find out if any changes in cell "stickiness" occur with low oxygen levels (at rest, at night, or with exertion) and if cells become "less sticky" with oxygen treatment. Study subjects will be seen before testing and 2 months after testing. In some cases (people with low oxygen levels during testing), study subjects will have been prescribed oxygen, and the investigators will test the effects of that treatment on the stickiness of red cells.
This study is designed to compare the accuracy of a noninvasive measurement of oxygen saturation compared to reference values obtained by a laboratory blood gas analyzer. Arterial blood samples will be collected from healthy adult subjects while undergoing a desaturation procedure wherein the concentration of oxygen inhaled is slowly reduced until the subject's arterial oxygen concentration is approximately 70%. During the desaturation, the subject's hand and arm without the arterial line will be subjected to motion at various times during the study. The subject will then be returned to breathing room air.
This study is designed to measure the trending accuracy of a noninvasive regional oximetry measurement of somatic oxygen saturation. Two large sensors (adult sensors) will be placed on the subject's forehead. Two investigational sensors (INVSENSOR00028) will be placed on the forearm of the volunteer. The values obtained by the INVSENSOR00028 will be compared to the reference value calculated from the arterial and venous blood measurements. Data will be collected from healthy adult subjects while undergoing a desaturation procedure wherein the concentration of oxygen inhaled is slowly reduced until the subject's arterial oxygen saturation is approximately 70%, while blood samples are drawn at prespecified reference points. The subject will then be returned to inhaling room air.
This study is designed to compare the accuracy of a noninvasive measurement of oxygen saturation compared to reference values obtained by a laboratory blood gas analyzer. Arterial blood samples will be collected from healthy adult subjects while undergoing a desaturation procedure wherein the concentration of oxygen inhaled is slowly reduced until the subject's arterial oxygen concentration is approximately 70%. During the desaturation, the subject's hand and arm without the arterial line will be subjected to motion.After completing the desaturation, the gas mixture will be returned to room air concentrations.
This study is designed to compare the accuracy of a noninvasive measurement of oxygen saturation compared to reference values obtained by a laboratory blood gas analyzer. Arterial blood samples will be collected from healthy adult subjects while undergoing a desaturation procedure wherein the concentration of oxygen inhaled is slowly reduced until the subject's arterial oxygen concentration is approximately 70%. The subject will then be returned to inhaling room air.
This study is designed to measure the trending accuracy of a noninvasive measurement of cerebral oxygen saturation. One Large sensor (adult sensor) and one INVSENSOR00009 will be placed on the subject's forehead. The values obtained by the INVSENSOR00009 will be compared to the values collected with the adult sensor.Data will be collected from healthy adult subjects while undergoing a desaturation procedure wherein the concentration of oxygen inhaled is slowly reduced until the subject's arterial oxygen saturation is approximately 70%. The subject will then be returned to inhaling room air.
It is standard practice in the United States and many parts of world to perform Gastrointestinal (GI) endoscopy with the patient under deep sedation. Obesity is accepted as a patient specific risk factor for hypoxic events during procedural sedation for GI endoscopic procedures. The Obese population has a higher prevalence of obstructive sleep apnea (OSA) which is characterized by repeated obstruction of the upper airway, and leads to apnea and desaturation. This prospective, randomized study was designed to compare the effectiveness of the high flow nasal cannula and the standard nasal cannula in morbidly obese (BMI \> 40) patients receiving deep intravenous sedation during colonoscopies. This study will assess whether use of the high flow nasal cannula (HFNC) leads to less intraoperative desaturation events compared to the current standard of care.
The clinical diagnosis of sleep apnea is difficult among ESRD patients since the characteristic clinical features of sleep apnea may be absent and since sleep-related symptoms, such as fatigue and sleepiness, may be attributed to kidney failure. However, the evaluation of patients with possible sleep apnea is the same among ESRD patients as in the general population.
Hemodialysis patients may experience drops in blood oxygen saturation during the hemodialysis treatment, which may lead to hypoxia in the tissues. The investigators hypothesize that: 1. The cumulative number, severity, or other characteristics of such deoxygenation episodes may be a predictor of adverse outcomes in hemodialysis patients. 2. There may be demographic, anthropometric, clinical, treatment prescription, lab analytical, and other parameters that correlate with the number and severity of deoxygenation episodes and, therefore, may be used for risk stratification. Further, some of these parameters may be modifiable.
The study utilizes microEEG (a novel miniaturized, FDA approved EEG device) to prospectively investigate the cerebral electrical activity of infants with Apnea, Bradycardia and Desaturation events. This project will also assess the feasibility of using the microEEG device in the Neonatal Intensive Care Unit (NICU) setting and the feasibility of remote centralized interpretation in this setting.
The primary aim of the study is to evaluate the effect of the method of delivery (vaginal delivery vs. cesarean section) on oxygen saturation in the first postpartum night. The investigators hypothesize that nocturnal desaturation occurs more frequently in cesarean section compared with vaginal delivery, expressed as either the duration of SpO2 below 90% or the Oxygen Desaturation Index (ODI). The ODI is defined as number of oxygen desaturations by at least 3 % per hour. Furthermore, the investigators expect a higher pulse rate and a lower mean and minimum SpO2 in the cesarean section group compared with the vaginal delivery group. The secondary aim of the study is to investigate how the upper body position during sleep (45 degree elevated vs. non-elevated) affects the oxygen saturation during the first postpartum night. The investigators hypothesize that an upper body elevation to 45 degrees decreases the incidence of desaturation events, expressed as either the duration of SpO2 below 90% or the ODI , compared with a non-elevated body position within each delivery group (vaginal delivery or cesarean section). The third aim of the study is to identify independent predictors of nocturnal desaturation in postpartum women. To that end, the investigators will administer questionnaires and collect demographic and clinical data according to various obstructive sleep apnea screening scores, including the P-SAP, STOP-Bang, and Epworth Sleepiness Scale. The investigators will also ask the patient to rate the pain during the study night on a verbal numerical rating scale.
Chronic obstructive lung disease (COPD) is characterized by airflow obstruction that is progressive over many years and is largely irreversible. Advanced COPD is associated with arterial oxygen desaturation leading to a series of complications and, ultimately, decreased survival. Long-term oxygen therapy can improve clinical outcomes in these patients, but the exact target of oxygen saturation that actually translates into improvements is not known. The basis for the work in this proposal is to focus a new approach to measure oxygen desaturation linked to daily activity. Accelerometers are used to measure daily activity and then synchronized with ambulatory oximetry to establish an activity/oxygen-saturation profile for individual patients. The three main objectives of this study are 1) determine the feasibility of AOM as a measurement of the temporal profile of oxygen saturation in patients with chronic lung disease; 2) determine if serial AOM-derived data is reliable and reproducible; and 3) determine thresholds of oxygen desaturation that are associated with different activity profiles
Using the 9 centers (Appendix B) involved with the planned multicenter NIRS comparative effectiveness trial the specific aims of this study are: 1. To demonstrate the feasibility of collecting rScO2 data from patients undergoing cardiac surgery in a multicenter study design. 2. To demonstrate the feasibility of using a standard algorithm for treating rScO2 desaturations during cardiac surgery in a multicenter study design.
This trial will test the hypothesis that the 6 minute walk test (6MWT) is not reproducible as a measure for oxygen desaturation.
* Determine the accuracy of the NTX wireless monitoring system alerts * Evaluate patient compliance with wearing device * Determine false alarm rates
* Reduction in time to detection of Clinically Significant events * Reduction of time to Intervention during Clinically Significant events * Reduction in the number of admissions to Intensive Care
Food consumption affects zinc metabolism within the body. Lowe and colleagues demonstrated that zinc is directed out of plasma and into tissues, such as into the liver, postprandially . It is likely that zinc absorbed with a meal is directed to the liver via the portal circulation whereas that zinc taken in the fasted state is more readily directed to peripheral blood plasma. Zinc taken with food is more likely to be bound to components of the food matrix and, therefore, it is not absorbed as efficiently by Zip4 ionic zinc transporters in the upper gastrointestinal tract. Some of the zinc in the food matrix may, however, be co-absorbed with amino acids over the whole length of the small intestine . Co-absorption of zinc with amino acids may explain the greater effects of zinc taken with food on omega-6 fatty acid desaturation . The investigators propose that this effect may be maximized by providing supplemental zinc complexed with amino acids. Since the zinc amino acid complex likely mimics the absorption and retention of zinc bound to protein in food, the investigators further propose that zinc, bound to amino acids taken in the fasted state will be directed into the cellular compartments more efficiently than zinc associated with gluconate. The primary aim in this study is to determine whether providing a zinc amino acid complex has a greater effect on indices of essential fatty acid desaturation compared with zinc gluconate when the zinc complexes are taken in the fasting state. The investigators hypothesize that taking a zinc amino acid (Zn-AA) complex in a fasted state daily for two weeks has a greater effect on the Fatty Acid Desaturase 1 (FADS1) activity compared with zinc gluconate. Also, if the uptake of ionic zinc gluconate into cellular compartments is reduced in comparison to Zn-AA because the zinc gluconate is retained in the plasma, two weeks of a daily zinc gluconate will have a greater effect on fasting plasma zinc concentrations compared to a Zn- AA complex.
This research study is being done to investigate the effect of changing an infant's body position on how hard the baby works to breathe, the baby's oxygen level, the baby's carbon dioxide level, the baby's lung volume, the baby's lung compliance (ability of the lung to expand and fill with air), and how frequently the baby develops clinically significant events such as apnea (baby stops breathing on his own), bradycardia (low heart rate), and desaturation (low oxygen) events.
It is standard practice in the United States and many parts of world to perform Gastrointestinal endoscopy with the patient under deep intravenous sedation. Obesity is accepted as a patient specific risk factor for hypoxic events during procedural sedation for GI endoscopic procedures. The obese population has a higher prevalence of obstructive sleep apnea (OSA), which is characterized by repeated obstruction of the upper airway, and leads to apnea and desaturation. This prospective, randomized study was designed to compare the effectiveness of the high flow nasal cannula, standard nasal cannula and standard face mask in morbidly obese patients with a high risk of sleep apnea, (BMI greater than 40, STOPBANG greater or equal to 5) receiving deep intravenous sedation during colonoscopies. This study will assess which method leads to a lower incidence of intraoperative desaturation events compared to the current standard of care.
The purpose of this study is to investigate if high flow nasal cannula (HFNC), as compared to conventional nasal cannula, improves oxygenation and prevents desaturation events in obese patients undergoing colonoscopy.