7 Clinical Trials for Various Conditions
The objective of this study is to investigate quantitative improvement in excessive tearing after administration of Bupivacaine, a local anesthetic, into the affected eyelids.
Prospective, open label, multi-center, non-randomized study designed to collect initial clinical data related to the safety and clinical performance of the Sinopsys Lacrimal Stent for use during repair of the lacrimal system in patients with functional or obstructive epiphora.
Epiphora or excessive tearing is a significant disability for many affected patients diminishing their quality of life. There is a growing consensus that injection of Botulinum Toxin A (BTX-A) into the lacrimal gland provides relief in patients with hyperlacrimation secondary to aberrant regeneration of the 7th nerve, and limited evidence that it might help to reduce normal tear production in patients with epiphora from anatomic or functional outflow obstructions. BTX-A has been injected both transconjunctivally into the palpebral lobe of the lacrimal gland and transcutaneously into the orbital lobe. Both delivery routes have been successful in symptom relief with minimal complications. However, the effectiveness of transconjunctival versus transcutaneous injections has not been systematically compared. Also, whether the incidence of side effects is related to the dosage, concentration, or location of injection is unknown and has also not been systematically studied. The investigators plan to conduct a randomized clinical trial in patients with functional tearing comparing the transcutaneous delivery route of BTX-A to the transconjunctival delivery route (the most common route described in the literature). The investigators will also compare the side effect profile of each delivery route.
Purpose: It is unknown whether instillation of a drop of anesthetic ophthalmic solution into the eye such as proparacaine hydrochloride 0.5% prior to probing and irrigation of the tear duct (lacrimal drainage) system improves participant comfort during the procedure. To date, there have been no formal studies evaluating the possible benefit of this pretreatment. Methods: Participants 18 years and older who present to the Louisiana State University or associated outpatient ophthalmology clinic(s) with a complaint of epiphora (excessive tearing) who necessitate bilateral lower lid probing and irrigation of the lacrimal drainage system will be enrolled in the study. One eye will be randomized to receive a drop of the anesthetic Proparacaine hydrochloride 0.5% and the other eye will receive a control drop of Balanced Salt Solution (BSS). Probing and irrigation will then be performed in the usual fashion. The participant will then be questioned via survey on a pain scale of 1-5 as to the amount of subjective pain experienced on each side during the procedure. Expected Results: Investigators expect participants will experience statistically significantly less pain in eyes that have received a drop of Proparacaine hydrochloride 0.5% prior to performance of probing and irrigation compared to the eyes which have received the control drop.
Purpose: It is unknown whether instillation of a drop of anesthetic ophthalmic solution into the eye such as proparacaine hydrochloride 0.5% prior to probing and irrigation of the tear duct (lacrimal drainage) system improves participant comfort during the procedure. To date, there have been no formal studies evaluating the possible benefit of this pretreatment. Methods: Participants 18 years and older who present to the William Beaumont Hospital - Royal Oak, Michigan outpatient ophthalmology clinic with a chief complaint of epiphora (excessive tearing) who necessitate bilateral lower lid probing and irrigation of the lacrimal drainage system will be enrolled in the study. One eye will be randomized to receive a drop of the anesthetic Proparacaine hydrochloride 0.5% and the other eye will receive a control drop of Balanced Salt Solution (BSS). Probing and irrigation will then be performed in the usual fashion. The participant will then be questioned via survey on a pain scale of 1-5 as to the amount of subjective pain experienced on each side during the procedure. Expected Results: Investigators expect participants will experience statistically significantly less pain in eyes that have received a drop of Proparacaine hydrochloride 0.5% prior to performance of probing and irrigation compared to the eyes which have received the control drop.
This project aims to test whether a newly designed lacrimal stent - the SlitStent - when placed into the lacrimal system in the standard fashion following a DCR surgery, will provide good symptomatic relief for epiphora and be well tolerated. Epiphora, or severe tearing, is both a very common debilitating symptom and a potential cause of dangerous infections (i.e. dacryocystitis and orbital cellulitis). DCR+lacrimal stenting surgery is 80-95% successful at improving epiphora, and the longer the stent remains in place, the better the long-term outcome. However, lacrimal stents that provide adequate circumferential force to facilitate post-DCR healing also occupy space and prevent good tear drainage until removed. Yet patients want complete symptomatic improvement as soon as possible, even if it compromises long-term results. This study aims to test a newly designed lacrimal stent that allows tears to drain through the lumen of the stent. The new stent is constructed by modifying a commercially available stent by placing openings along the side of the stent using a process developed by a University of Michigan engineer/collaborator. Following slit placement, the stent will be gas-sterilized for surgery. Patient who are scheduled for DCR+stenting surgery who provide informed consent will be randomized 2:1 to receive the investigational SlitStent or the standard commercially available stent. Following surgery, patients will be assessed both clinically, which is standard of care, and via a patient questionnaire.
Epiphora, or uncontrolled tearing of the eyes, represents a common presenting complaint of patients seen by ophthalmologists. Epiphora may be due to non-obstructive causes, such as tear hypersecretion or functional tear pump failure, or obstructive causes. Functional tear pump failure may result from malposition of the eyelids, such as an abnormal out-turning (ectropion) or in-turning (entropion) of the eyelid. Currently methods to diagnose partial nasolacrimal duct obstruction are purely qualitative in nature. Our research goal is to quantitatively measure the pressure generated during conventional probing and irrigation (P\&I), and to measure the resistance to irrigation of the nasolacrimal drainage system. The investigators will measure the pressure generated during conventional P\&I using a disposable in-line pressure transducer. In addition, the investigators will use a syringe pump to deliver a constant flow rate of saline through a nasolacrimal cannula and measure the steady state irrigation pressure using the in-line transducer and digital pressure monitor. Resistance can be directly calculated from the known flow rate and pressure measurements. The investigators will compare both the pressure generated during P\&I and the lacrimal drainage resistance between patients with lacrimal drainage obstruction and controls patients with no obstruction (functional tear pump failure) as determined by clinical exam. Clinical applications for measuring lacrimal drainage resistance include quantifying partial nasolacrimal duct obstruction, guiding the choice of surgical procedure, and determining the success of lacrimal drainage procedures.